Patient–ventilator synchrony during non-invasive pressure support ventilation with the helmet device is often compromised when conventional pneumatic triggering and cycling-off were used. A possible solution to this shortcoming is to replace the pneumatic triggering with neural triggering and cycling-off—using the diaphragm electrical activity (EAdi). This signal is insensitive to leaks and to the compliance of the ventilator circuit. Randomized, single-blinded, experimental study. University Hospital. Seven healthy human volunteers. Pneumatic triggering and cycling-off were compared to neural triggering and cycling-off during NIV delivered with the helmet. Triggering and cycling-off delays, wasted efforts, and breathing comfort were determined during restricted breathing efforts (<20% of voluntary maximum EAdi) with various combinations of pressure support (PSV) (5, 10, 20 cm H2O) and respiratory rates (10, 20, 30 breath/min). During pneumatic triggering and cycling-off, the subject–ventilator synchrony was progressively more impaired with increasing respiratory rate and levels of PSV (p < 0.001). During neural triggering and cycling-off, effect of increasing respiratory rate and levels of PSV on subject–ventilator synchrony was minimal. Breathing comfort was higher during neural triggering than during pneumatic triggering (p < 0.001). The present study demonstrates in healthy subjects that subject–ventilator synchrony, trigger effort, and breathing comfort with a helmet interface are considerably less impaired during increasing levels of PSV and respiratory rates with neural triggering and cycling-off, compared to conventional pneumatic triggering and cycling-off.Keywords
This publication has 37 references indexed in Scilit:
- Improved Synchrony and Respiratory Unloading by Neurally Adjusted Ventilatory Assist (NAVA) in Lung-Injured RabbitsPediatric Research, 2007
- Effectiveness of mask and helmet interfaces to deliver noninvasive ventilation in a human model of resistive breathingJournal of Applied Physiology, 2005
- Noninvasive ventilation in hypercapnic acute respiratory failure due to chronic obstructive pulmonary disease vs. other conditions: effectiveness and predictors of failureIntensive Care Medicine, 2005
- Assessment of Physiologic Variables and Subjective Comfort Under Different Levels of Pressure Support VentilationChest, 2004
- Non-invasive positive pressure ventilation for treatment of respiratory failure due to exacerbations of chronic obstructive pulmonary disease2004
- Prolonged Neural Expiratory Time Induced by Mechanical Ventilation in InfantsPediatric Research, 2004
- New advances in the use of noninvasive ventilation for acute hypoxaemic respiratory failureEuropean Respiratory Journal, 2003
- Non-invasive ventilation delivered by conventional interfaces and helmet in the emergency departmentEuropean Journal of Emergency Medicine, 2003
- Physiological effects of flow and pressure triggering during non- invasive mechanical ventilation in patients with chronic obstructive pulmonary diseaseThorax, 1997
- Noninvasive Ventilation for Acute Exacerbations of Chronic Obstructive Pulmonary DiseaseNew England Journal of Medicine, 1995