Influence of the sinusoidal supply frequency on the induction motor stray load losses
- 1 October 2012
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1553572X,p. 1847-1851
Abstract
This papers deals with the influence of the supply frequency on the induction motor stray load losses. Due to the complexity of the stray load losses computation, a fully experimental approach has been chosen. Following the International Standard IEEE 112 method B, the additional losses have been determined in the supply frequency range of 30 Hz up to 80 Hz. As requested by this standard, a sinusoidal supply has been adopted for an 11 kW, 50 Hz, 400 V induction motor. In order to understand if the motor stator phase connection influences the stray load losses, the tests have been performed with both star and delta connections. The test results didn't show any influence of the motor connection on the stray load losses. About the supply frequency, the obtained results have shown a direct dependence of the stray load losses with the supply frequency. As a consequence, waiting the new International Standards which will define the rules for the induction motor efficiency determination with inverter supply, the results reported in this paper warn that the stray load losses are directly depending on the supply frequency and this cannot be neglected when the motor is used in variable frequency drive, in particular during the flux weakening operation.Keywords
This publication has 19 references indexed in Scilit:
- Induction motor EU standards for efficiency evaluation: The scenario after IEC 60034-2-12011
- Standards for Efficiency of Electric MotorsIEEE Industry Applications Magazine, 2010
- An Evaluation of Induction Machine Stray Load Loss From Collated Test ResultsIEEE Transactions on Industry Applications, 2010
- Impact of the Supply Voltage on the Stray-Load Losses in Induction MotorsIEEE Transactions on Industry Applications, 2010
- A Comparison of direct and indirect measurement of induction motor efficiency2009
- Comparison of measured and analytically calculated stray load losses in standard cage induction machines2008
- Comparison of the efficiency depending on test standards of three-phase cage induction machine2008
- Induction Motor Equivalent Circuit Including the Stray Load Losses in the Machine Power BalanceIEEE Transactions on Energy Conversion, 2008
- When loads stray: Evaluation of Different Measurement Methods to Determine Stray Load Losses in Induction MachinesIEEE Industrial Electronics Magazine, 2008
- The Economics of Pre-EPAct Motors Operating in IndustryConference Record of 2007 Annual Pulp and Paper Industry Technical Conference, 2007