Ventricular tachyarrhythmia treatment and prevention by subthreshold stimulation with stretchable epicardial multichannel electrode array
- 31 March 2023
- journal article
- research article
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 9 (13) , eadf6856
Abstract
The implantable cardioverter-defibrillator (ICD) is an effective method to prevent sudden cardiac death in high-risk patients. However, the transvenous lead is incompatible with large-area electrophysiological mapping and cannot accommodate selective multichannel precision stimulations. Moreover, it involves high-energy shocks, resulting in pain, myocardial damage, and recurrences of ventricular tachyarrhythmia (VTA). We present a method for VTA treatment based on subthreshold electrical stimulations using a stretchable epicardial multichannel electrode array, which does not disturb the normal contraction or electrical propagation of the ventricle. In rabbit models with myocardial infarction, the infarction was detected by mapping intracardiac electrograms with the stretchable epicardial multichannel electrode array. Then, VTAs could be terminated by sequential electrical stimuli from the epicardial multichannel electrode array beginning with low-energy subthreshold stimulations. Last, we used these subthreshold stimulations to prevent the occurrence of additional VTAs. The proposed protocol using the stretchable epicardial multichannel electrode array provides opportunities toward the development of innovative methods for painless ICD therapy.Keywords
This publication has 52 references indexed in Scilit:
- Editorial Right heart perforation by pacemaker leadsArchives of Medical Science, 2012
- Efficacy and safety of different antitachycardia pacing sites in the termination of ventricular tachycardia in patients with biventricular implantable cardioverter-defibrillatorEP Europace, 2011
- Left ventricular lead placement in cardiac resynchronization therapy: where and how?EP Europace, 2009
- Requirement for coronary sinus lead interventions and effectiveness of endovascular replacement during long-term follow-up after implantation of a resynchronization deviceEP Europace, 2009
- Pacemaker and ICD lead extraction with electrosurgical dissection sheaths and standard transvenous extraction systems: results of a randomized trialEP Europace, 2007
- Mortality Reduction by Implantable Cardioverter-Defibrillators in High-Risk Patients With Heart Failure, Ischemic Heart Disease, and New-Onset Ventricular ArrhythmiaJACC, 2005
- Prospective Randomized Multicenter Trial of Empirical Antitachycardia Pacing Versus Shocks for Spontaneous Rapid Ventricular Tachycardia in Patients With Implantable Cardioverter-DefibrillatorsCirculation, 2004
- 991-73 Ultrarapid Subthreshold Stimulation Delivered via Epicardial Patches can Terminate Reentrant Ventricular Tachycardia in a Canine ModelJACC, 1995
- Ultrarapid subthreshold stimulation for termination of atrioventricular node reentrant tachycardiaJACC, 1992
- Adrenaline: Mechanism of Action on the Pacemaker Potential in Cardiac Purkinje FibersScience, 1968