Effect of simulated pulpal blood flow rate on the rise in pulp chamber temperature during direct fabrication of exothermic provisional restorations
Author:
- 2 January 2017
- journal article
- Published by Wiley in International Endodontic Journal
- Vol. 50 (11) , 1097-1103
Abstract
Aim: To evaluate ex vivo the effect of several simulated pulpal blood flow rates on the change in pulp chamber temperature during direct fabrication of a provisional restoration using a polymethylmethacrylate (PMMA) resin.Methodology: Fifteen noncarious human premolars were prepared for complete coverage restorations. A curved needle connected to a peristaltic pump simulated the pulp blood flow. Two K‐type thermocouples connected to a digital thermometer were placed in the pulp chamber, and the assembly was placed in an incubator at 37 °C. Three provisional crowns were made for each specimen using no water flow (group 1), a 1‐mL min−1 flow rate (group 2) and a 0.5‐mL/min−1 flow rate (group 3). The pulp chamber temperature was recorded continuously during polymerization until the temperature increase peaked and started to decrease and reached the baseline temperature (37 °C). The temperature increase was measured for the three water flow conditions. Data were analysed statistically using descriptive statistics, repeated measures one‐way analysis of variance (anova) with Greenhouse–Geisser correction and Bonferroni tests. The level of significance was set at P < 0.05.Results: All of the groups were associated with an increased pulp chamber temperature. Groups with flow rates at 1 and 0.5 mL min−1 had a significantly lower temperature rise when compared to the group without water flow (P < 0.001).Conclusions: Direct fabrication of provisional restorations can cause a critical increase in pulp chamber temperature. However, in the presence of simulated pulpal blood flow rates of 1 or 0.5 mL min−1, the increase in pulp chamber temperature did not exceed the critical threshold (5.6 °C).Keywords
This publication has 15 references indexed in Scilit:
- Temperature rise on dentin caused by temporary crown and fixed partial denture materials: Influencing factorsJournal of Dentistry, 2010
- A review of heat transfer in human tooth—Experimental characterization and mathematical modelingDental Materials, 2010
- Parameters Influencing Increase in Pulp Chamber Temperature with Light-curing Devices: Curing Lights and Pulpal Flow RatesOperative Dentistry, 2010
- Temperature change in pulp cavity in vitro during the polymerization of provisional resinsDental Materials, 2009
- Effect of simulated pulpal microcirculation on intrapulpal temperature changes following application of heat on tooth surfacesInternational Endodontic Journal, 2009
- Increases in intrapulpal temperature during polymerization of composite resinThe Journal of Prosthetic Dentistry, 2006
- A review of selected dental literature on contemporary provisional fixed prosthodontic treatment: Report of the Committee on Research in Fixed Prosthodontics of the Academy of Fixed ProsthodonticsThe Journal of Prosthetic Dentistry, 2003
- Laser-induced thermal events in empty and pulp-filled dental pulp chambersLasers in Surgery and Medicine, 1998
- Intrapulpal Temperature during Cavity PreparationJournal of Dental Research, 1965
- Pulp response to externally applied heatOral Surgery, Oral Medicine, Oral Pathology, 1965