Augmentation of Pedicle Screw Fixation Strength Using an Injectable Calcium Sulfate Cement
Authors:
- 1 November 2008
- journal article
- biomechanics
- Published by Wolters Kluwer Health in Spine
- Vol. 33 (23) , 2503-2509
Abstract
Study Design. An in vivo landrace model of cement augmentation of pedicle screw was established, and axial pull-out tests and histological analysis were performed. Objective. To investigate the long-term in vivo biomechanical performance of pedicle screws augmented with calcium sulfate cement. Summary of Background Data. Little information is available on the long-term biomechanical performance of pedicle screws augmented with calcium sulfate cement in vivo. Methods. Ten pedicle screws were implanted into the lumbar vertebrae of 15 adult females landraces weighing 105 to 115 kg. The pedicle screws were augmented with Polymethyl methacrylate (PMMA), augmented with the calcium sulfate cement, or not augmented. The landraces were randomized into 3 study periods of day 1, 6 weeks, and 12 weeks. At the end of the assigned study periods, the animals were killed and axial pull-out tests and histological analyses were conducted on the isolated specimen vertebrae. Results. No significant difference was found among the 1-day, 6-week,and 12-week control group (P > 0.18), no significant difference was found among the 1-day, 6-week and 12-week PMMA group (P > 0.59), and no significant difference was found among the 1-day, 6-week and 12-week calcium sulfate group (P > 0.27). The maximum POS of the PMMA groups was significantly greater than that of the calcium sulfate groups (P < 0.002), the maximum POS of the calcium sulfate groups was significantly greater than that of the control groups (P < 0.004). Histologically progressive absorption of the calcium sulfate was evident. The bone walls around the screws in the 12-week calcium sulfate group were statistically significantly thicker than that of the 12-week control group and that of the 12-week PMMA group. Conclusion. Results of this study demonstrate that the injectable calcium sulfate cement can significantly improve the immediate POS of pedicle screw fixation, and this effect can be maintained even if the calcium sulfate cement has been absorbed completely, which may result from that the calcium sulfate cement resorption paralleled bone ingrowth.Keywords
This publication has 19 references indexed in Scilit:
- Biomechanical Comparison of Anatomic Trajectory Pedicle Screw versus Injectable Calcium Sulfate Graft-Augmented Pedicle Screw for Salvage in Cadaveric Thoracic BoneJournal of Spinal Disorders & Techniques, 2006
- Role of BMP, βig-h3, and Chitosan in Early Bony Consolidation in Distraction Osteogenesis in a Dog ModelPlastic and Reconstructive Surgery, 2002
- CALCIUM SULFATE– AND CALCIUM PHOSPHATE–BASED BONE SUBSTITUTESOrthopedic Clinics of North America, 1999
- Revision of Failed Pedicle Screws Using Hydroxyapatite CementSpine, 1998
- Revision Pedicle ScrewsSpine, 1998
- Osteoblast adherence and resorption activity of isolated osteoclasts on calcium sulphate hemihydrateBiomaterials, 1995
- Repair of Failed Transpedicle Screw FixationSpine, 1994
- An Experimental Study on Transpedicular Screw Fixation in Relation to Osteoporosis of the Lumbar SpineSpine, 1991
- Plaster of Paris as an Alloplastic Implant in the Frontal SinusJAMA Otolaryngology–Head & Neck Surgery, 1981