Biomechanical Comparison of Anatomic Trajectory Pedicle Screw versus Injectable Calcium Sulfate Graft-Augmented Pedicle Screw for Salvage in Cadaveric Thoracic Bone
Authors:
- Alihan DerincekADAlihan Derincek
- Chunhui WuCWChunhui Wu
- Amir MehbodAMAmir Mehbod
- Ensor E. TransfeldtETEnsor E. Transfeldt
- 1 June 2006
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Spinal Disorders & Techniques
- Vol. 19 (4) , 286-291
Abstract
Many salvage options for failed thoracic pedicle screws exist including the use of a different trajectory or the augmentation of the screw with polymethylmethacrylate cement. Although polymethylmethacrylate immediately increases the construct stiffness and the pull-out strength, it may cause bone necrosis, toxin relaxation, and/or neural injury. On the other hand, calcium sulfate bone grafts have a high potential for biologic incorporation and no thermal damage effect. In the current study, polyaxial pedicle screws were first inserted with a straightforward approach on both sides in 17 fresh human cadaveric thoracic vertebrae. The maximal insertion torque for each screw was measured and then the pull-out strengths were recorded. Afterward, these pedicle screws were randomly assigned to be replaced either by graft augmentation or by anatomic trajectory technique for salvage. The graft-augmented screws were placed using the previous holes. The maximum insertional torque for each anatomic trajectory screw was measured. Finally, the pull-out strengths of the revision screws were recorded. The mean maximum insertional torque decreased with the anatomic trajectory salvage technique when compared with the straightforward approach, 0.23 versus 0.38 Nm, respectively (P=0.003). The anatomic trajectory revision resulted in decreased pull-out strength when compared with the pull-out strength of the straightforward technique, 297 versus 469 N, respectively (P=0.003). The calcium sulfate graft augmentation increased the pull-out strength when compared with the pull-out strength of the straightforward technique, 680 versus 477 N, respectively (P=0.017). The mean pull-out strength ratio of revised screw to original was 0.71 for anatomic trajectory and 1.8 for graft-augmented screws, a statistically significant difference (P=0.002).Keywords
This publication has 33 references indexed in Scilit:
- Physical Characteristics of Polyaxial-Headed Pedicle Screws and Biomechanical Comparison of Load With Their FailureSpine, 2003
- The Use of a Surgical Grade Calcium Sulfate as a Bone Graft SubstituteClinical Orthopaedics and Related Research, 2001
- Reinforcement of Thoracolumbar Burst Fractures With Calcium Phosphate CementSpine, 1998
- 1997 Volvo Award Winner in Clinical StudiesSpine, 1997
- Spinal Deformity in MyelodysplasiaSpine, 1997
- Early complications of spinal pedicle screwEuropean Spine Journal, 1997
- Pedicle screw fixation in spinal disorders: A European viewEuropean Spine Journal, 1997
- Management of Rigid Post-traumatic KyphosisSpine, 1996
- Neurosurgical Management of Thoracic and Lumbar Vertebral Osteomyelitis and Discitis in Adults: A Review of 43 Consecutive Surgically Treated PatientsNeurosurgery, 1996
- Oligosegmental Correction of Post-Traumatic Thoracolumbar Angular KyphosisSpine, 1993