New parameters for evaluating corneal biomechanics and intraocular pressure after small-incision lenticule extraction by Scheimpflug-based dynamic tonometry
- 1 June 2017
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 43 (6) , 803-811
Abstract
To evaluate parameters and dynamic corneal densitometry with a new dynamic Scheimpflug analyzer (Corvis ST) in eyes having small-incision lenticule extraction (SMILE). Qvision, Vithas Virgen del Mar Hospital, Almería, Spain. Retrospective case series. The study comprised eyes from the same institution having small-incision lenticule extraction surgery. Preoperative and 1-month postoperative measurements were taken. Forty-three eyes were evaluated. The mean difference in intraocular pressure (IOP) and biomechanically corrected IOP before and after surgery was 2.24 mm Hg ± 1.26 mm (SD) (P = .001) and 0.57 ± 1.77 mm Hg (P = .04), respectively. All dynamic Scheimpflug analyzer parameters changed significantly after surgery (P < .05). The variation in each parameter was correlated with the removed corneal thickness (P < .05), except the stiffness parameter at the first applanation (P = .15). None of the 4 dynamic corneal densitometry parameters changed significantly as a result of surgery (P ≥ .29). A new sign, described as an inclined brightness fringe moving through the corneal periphery, appeared preoperatively in eyes with higher dynamic corneal densitometry. This sign was more prevalent postoperatively (48.8% versus 72.1%) (P = .04). The biomechanically corrected IOP measured after surgery with the dynamic Scheimpflug analyzer showed better agreement with the preoperative values than IOP. The stiffness parameter was not dependent on the amount of removed corneal thickness. A new sign correlated with dynamic corneal densitometry was found and might be related to changes in corneal hydration and biomechanics.Keywords
This publication has 16 references indexed in Scilit:
- Corneal Thickness After SMILE Affects Scheimpflug-based Dynamic TonometryJournal of Refractive Surgery, 2016
- Influence of Pachymetry and Intraocular Pressure on Dynamic Corneal Response Parameters in Healthy PatientsJournal of Refractive Surgery, 2016
- Short-Term Outcomes of Small-Incision Lenticule Extraction (SMILE) for Low, Medium, and High MyopiaEuropean Journal of Ophthalmology, 2016
- Evaluation of Changes in Human Corneas After Femtosecond Laser-Assisted LASIK and Small-Incision Lenticule Extraction (SMILE) Using Non-Contact Tonometry and Ultra-High-Speed Camera (Corvis ST)Current Eye Research, 2015
- Development and validation of a correction equation for Corvis tonometryComputer Methods in Biomechanics and Biomedical Engineering, 2015
- Association Between Corneal Deformation and Ease of Lenticule Separation From Residual Stroma in Small Incision Lenticule ExtractionCornea, 2015
- Corneal biomechanical properties after LASIK, ReLEx flex, and ReLEx smile by Scheimpflug-based dynamic tonometryGraefe's Archive for Clinical and Experimental Ophthalmology, 2014
- Repeatability of Ocular Biomechanical Data Measurements With a Scheimpflug-Based Noncontact Device on Normal CorneasJournal of Refractive Surgery, 2013
- Effects of Altered Corneal Stiffness on Native and Postoperative LASIK Corneal Biomechanical Behavior: A Whole-eye Finite Element AnalysisJournal of Refractive Surgery, 2009
- Corneal Ectasia After Laser In Situ Keratomileusis in Patients Without Apparent Preoperative Risk FactorsCornea, 2006