Abstract
Precise measurement of the blood flow velocity in major arteries is important for the assessment of circulation dysfunction but challenging when using a one-dimensional (1D) ultrasound transducer array. Current available ultrasound velocimetry methods are susceptible to the probe-to-vessel angle and require the vessels to be well-aligned within the imaging plane of the 1D transducer array. In this study, a novel angle-independent velocimetry (VT-vUS) based on the ultrasound speckle decorrelation analysis of the ultrasound field signal is proposed to measure the blood flow velocity using a conventional 1D ultrasound transducer array. We first introduced the principle and evaluated this technique with numerical simulation and phantom experiments, which demonstrated that VT-vUS can accurately reconstruct the velocity magnitude of blood flow at arbitrary probe-to-vessel angles for different preset flow speeds (up to ~2.5 m/s). Further, we applied VT-vUS to measure the pulsatile flow of the radial artery and carotid artery in a healthy volunteer. Results show that the absolute velocity profiles obtained with VT-vUS at different probe-to-vessel angles have high consistency and agree well with the absolute speed obtained with the color Doppler-corrected velocimetry throughout the cardiac cycle. With the ability to alleviate the dependency on probe-to-vessel angle, VT-vUS has the potential for circulation-related disease screening in clinical practices.Keywords
Funding Information
- National Natural Science Foundation of China (62275116, 62220106006, 12426312)
- Ministry of Science and Technology of the People’s Republic of China (2023YFEO209600)
- Science, Technology and Innovation Commission of Shenzhen Municipality (JCYJ20210324104208023, SGDX20230116091645005, JSGGKQTD20221103174704003)
- Guangdong Provincial Department of Science and Technology (2021QN02Y274, 2022A1515011984)
This publication has 43 references indexed in Scilit:
- Ultrasound Speckle Decorrelation Analysis‐Based Velocimetry for 3D‐Velocity‐Components Measurement Using a 1D Transducer ArrayAdvanced Science, 2024
- Rates of Stroke in Patients With Different Presentations of Carotid Artery StenosisJournal of Vascular Surgery, 2023
- In vivo whole brain microvascular imaging in mice using transcranial 3D Ultrasound Localization MicroscopyEBioMedicine, 2022
- Coronary Flow Assessment Using 3-Dimensional Ultrafast Ultrasound Localization MicroscopyJACC: Cardiovascular Imaging, 2022
- Functional Ultrasound Speckle Decorrelation‐Based Velocimetry of the BrainAdvanced Science, 2020
- Blood Speckle-Tracking Based on High–Frame Rate Ultrasound Imaging in Pediatric CardiologyJournal of the American Society of Echocardiography, 2020
- In Vivo Blood Velocity Vector Imaging Using Adaptive Velocity Compounding in the Carotid Artery BifurcationUltrasound in Medicine & Biology, 2019
- Common Carotid Artery Flow Measured by 3-D Ultrasonic Vector Flow Imaging and Validated with Magnetic Resonance ImagingUltrasound in Medicine & Biology, 2017
- Vector flow imaging techniques: An innovative ultrasonographic technique for the study of blood flowJournal of Clinical Ultrasound, 2017
- Volume flow measurement using doppler and grey-scale decorrelationUltrasound in Medicine & Biology, 2001