Yongchao Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yongchao Wang has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Jianbo Tang
Department of Biomedical Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Southern University of Science and Technology, Shenzhen, Guangdong 518055, China
7 shared publications Wei Chen
Department of Biomedical Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Southern University of Science and Technology, Shenzhen, Guangdong 518055, China
2 shared publications- Yang Liu
Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
2 shared publications Anna Devor
Department of Biomedical Engineering, Boston University, Boston, MA, USA
1 shared publication- Bingxue Liu
Department of Electrical and Computer Engineering, Boston University, Massachusetts 02215, USA
1 shared publication - David A. Boas
Boston University, Neurophotonics Center, Department of Biomedical Engineering, Boston, Massachusetts, United States
1 shared publication
Latest Publications
- Open Access
- 25 September 2026
- Published by Elsevier in SSRN Electronic Journal
g 1 Analysis-Dynamic OCT for Label-Free Quantification of Tissue Effective Diffusion Coefficient
Dynamic optical coherence tomography (dOCT) enables label-free imaging of tissue activity, but conventional metrics remain empirical and highly dependent on acquisition parameters. Here, we reformulate dOCT assessment as a parameter-estimation problem by deriving an effective diffusion coefficient (Deff) through fitting the normalized first-order field autocorrelation (g1) with a diffusion-dominated decay model. Numerical simulations define the estimator’s valid range (0–0.1 µm²/s) and elucidate the coupled effects of sampling parameters and active-transport contamination on fitting precision. Applied to ex vivo 4T1 murine tumor slices, Deff mapping detects chemotherapy-induced suppression of intracellular dynamics and distinguishes the distinct temporal kinetics of doxorubicin versus 5-fluorouracil. Notably, unlike the standard-deviation metric, Deff is largely insensitive to focal-position-induced intensity variations, establishing it as a physically interpretable and acquisition-robust descriptor for longitudinal drug-response monitoring.
- 25 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open Accessg 1 Analysis-Dynamic OCT for Label-Free Quantification of Tissue Effective Diffusion Coefficient
Dynamic optical coherence tomography (dOCT) enables label-free imaging of tissue activity, but conventional metrics remain empirical and highly dependent on acquisition parameters. Here, we reformulate dOCT assessment as a parameter-estimation problem by deriving an effective diffusion coefficient (Deff) through fitting the normalized first-order field autocorrelation (g1) with a diffusion-dominated decay model. Numerical simulations define the estimator’s valid range (0–0.1 µm²/s) and elucidate the coupled effects of sampling parameters and active-transport contamination on fitting precision. Applied to ex vivo 4T1 murine tumor slices, Deff mapping detects chemotherapy-induced suppression of intracellular dynamics and distinguishes the distinct temporal kinetics of doxorubicin versus 5-fluorouracil. Notably, unlike the standard-deviation metric, Deff is largely insensitive to focal-position-induced intensity variations, establishing it as a physically interpretable and acquisition-robust descriptor for longitudinal drug-response monitoring.
- 30 June 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (7) , 3960-3971
First-order field autocorrelation function analysis-based dynamic OCT for tissue viability assessment
This work introduces g 1 -dOCT, which derives a dynamic index I d from the first-order field autocorrelation function for long-term tissue viability assessment. The method encodes activity intensity directly as image brightness, offering intuitive interpretability without complex post-processing. Its key advantage lies in the stability of I d across varying imaging conditions, enabling direct semi-quantitative comparison of tissue activity in longitudinal drug studies, particularly well-suited for pharmacological screening in high-throughput settings, such as multi-drug treatment of 3D tissue constructs in 48-well plates. Experimental validation on tumor slices during 46-hour chemotherapy and on dynamic hepatocyte apoptosis shows that g 1 -dOCT maintains consistent performance over extended time courses, establishing it as a reliable tool for longitudinal tissue dynamics evaluation in large-scale drug screening.
- 30 June 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (7) , 3960-3971
First-order field autocorrelation function analysis-based dynamic OCT for tissue viability assessment
This work introduces g 1 -dOCT, which derives a dynamic index I d from the first-order field autocorrelation function for long-term tissue viability assessment. The method encodes activity intensity directly as image brightness, offering intuitive interpretability without complex post-processing. Its key advantage lies in the stability of I d across varying imaging conditions, enabling direct semi-quantitative comparison of tissue activity in longitudinal drug studies, particularly well-suited for pharmacological screening in high-throughput settings, such as multi-drug treatment of 3D tissue constructs in 48-well plates. Experimental validation on tumor slices during 46-hour chemotherapy and on dynamic hepatocyte apoptosis shows that g 1 -dOCT maintains consistent performance over extended time courses, establishing it as a reliable tool for longitudinal tissue dynamics evaluation in large-scale drug screening.
- 17 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (9) , 1213-1221
Adaptive Singular Value Decomposition-Based Hyperecho Suppression for Diagnostic Power Doppler Ultrasound Image Processing
The power Doppler (PD) ultrasound imaging provides high-quality, noninvasive visualization of blood flow and has the potential to be used for circulation screening. However, its application in human arterial imaging remains challenging due to the presence of complex hyperechoic moving structures (HMSs). In this study, we propose an adaptive singular value decomposition (SVD) filtering strategy for HMS suppression. The proposed method used a k-means clustering algorithm directly on prebeamformed IQ data to segment HMS and non-HMS regions, followed by an adaptive SVD filtering strategy tailored to each tissue type. Compared to the existing SVD filtering methods, the proposed approach can effectively suppress the HMS artifacts. In addition, the human carotid artery imaging experiments demonstrate significant improvement in HMS suppression throughout cardiac cycles and across various imaging locations. With such capability, we believe that the proposed strategy will be a useful tool in applying PD for the 3-D imaging of human blood vessels.
- 17 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (9) , 1213-1221
Adaptive Singular Value Decomposition-Based Hyperecho Suppression for Diagnostic Power Doppler Ultrasound Image Processing
The power Doppler (PD) ultrasound imaging provides high-quality, noninvasive visualization of blood flow and has the potential to be used for circulation screening. However, its application in human arterial imaging remains challenging due to the presence of complex hyperechoic moving structures (HMSs). In this study, we propose an adaptive singular value decomposition (SVD) filtering strategy for HMS suppression. The proposed method used a k-means clustering algorithm directly on prebeamformed IQ data to segment HMS and non-HMS regions, followed by an adaptive SVD filtering strategy tailored to each tissue type. Compared to the existing SVD filtering methods, the proposed approach can effectively suppress the HMS artifacts. In addition, the human carotid artery imaging experiments demonstrate significant improvement in HMS suppression throughout cardiac cycles and across various imaging locations. With such capability, we believe that the proposed strategy will be a useful tool in applying PD for the 3-D imaging of human blood vessels.
- 1 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (6) , 709-720
Adaptive Color Doppler for Axial Velocity Imaging of Microvessel Networks
Directional filtering has been applied to distinguish between the ascending and descending flows in functional ultrasound imaging, however, it can lead to incorrect measurement of the flow speed and direction when using the directional filtering-based color Doppler ultrasound velocimetry (iCD_US). Specifically, in cases where the frequency spectrum bandwidth of a unidirectional flow extends into both negative and positive frequency domains, directional filtering may erroneously produce bidirectional velocities. Here, we propose an adaptive color Doppler ultrasound technique (aCD_US), which addresses this issue by analyzing the envelope of the Doppler spectrum and then adaptively using the whole spectrum integration or directional filtering-based approach to estimate the flow velocity. The proposed aCD_US was validated through numerical simulations and phantom experiments under various flow conditions, demonstrating superior performance in estimating axial velocities of unidirectional, bidirectional, and horizontal flows. Notably, numerical simulations showed that aCD_US achieved over 90% directional accuracy and less than 15% velocity deviation at signal-to-noise ratios larger than -1 dB. In vivo experiments on mouse cerebral blood flow further highlighted its advantages, with aCD_US surpassing conventional color Doppler velocimetry and iCD_US in reconstructing axial flow velocity maps. The quantitative comparison between aCD_US and vULM shows a strong overall correlation in their axial velocity measurements, with a Pearson correlation coefficient of 0.760 (p = 0.000). These results demonstrate the advantage of aCD_US in precise microvessel networks velocity quantification and its potential to advance microvascular imaging accuracy in both research and clinical applications.
- 1 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (6) , 709-720
Adaptive Color Doppler for Axial Velocity Imaging of Microvessel Networks
Directional filtering has been applied to distinguish between the ascending and descending flows in functional ultrasound imaging, however, it can lead to incorrect measurement of the flow speed and direction when using the directional filtering-based color Doppler ultrasound velocimetry (iCD_US). Specifically, in cases where the frequency spectrum bandwidth of a unidirectional flow extends into both negative and positive frequency domains, directional filtering may erroneously produce bidirectional velocities. Here, we propose an adaptive color Doppler ultrasound technique (aCD_US), which addresses this issue by analyzing the envelope of the Doppler spectrum and then adaptively using the whole spectrum integration or directional filtering-based approach to estimate the flow velocity. The proposed aCD_US was validated through numerical simulations and phantom experiments under various flow conditions, demonstrating superior performance in estimating axial velocities of unidirectional, bidirectional, and horizontal flows. Notably, numerical simulations showed that aCD_US achieved over 90% directional accuracy and less than 15% velocity deviation at signal-to-noise ratios larger than -1 dB. In vivo experiments on mouse cerebral blood flow further highlighted its advantages, with aCD_US surpassing conventional color Doppler velocimetry and iCD_US in reconstructing axial flow velocity maps. The quantitative comparison between aCD_US and vULM shows a strong overall correlation in their axial velocity measurements, with a Pearson correlation coefficient of 0.760 (p = 0.000). These results demonstrate the advantage of aCD_US in precise microvessel networks velocity quantification and its potential to advance microvascular imaging accuracy in both research and clinical applications.
- 30 January 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (2) , 778-789
Optical coherence tomography guided automatic robotic craniotomy surgery platform
A transparent craniotomy window is required for optical brain imaging; however, traditional surgical preparation requires well-trained surgeons, is time-consuming, and suffers from low success rates. To address this issue, we present an automatic craniotomy platform combining optical coherence tomography (OCT) with an automated drilling machine. The OCT provides 3D skull data to guide a homemade closed-loop high-precision drill for controlled craniotomies, achieving a 100% success rate in creating small, large, and thinned windows. A synthetic transparent window was installed after skull excision. This system enables high-quality OCT angiography, velocimetry, and ultrasound imaging, offering an efficient tool for brain research.
- 30 January 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (2) , 778-789
Optical coherence tomography guided automatic robotic craniotomy surgery platform
A transparent craniotomy window is required for optical brain imaging; however, traditional surgical preparation requires well-trained surgeons, is time-consuming, and suffers from low success rates. To address this issue, we present an automatic craniotomy platform combining optical coherence tomography (OCT) with an automated drilling machine. The OCT provides 3D skull data to guide a homemade closed-loop high-precision drill for controlled craniotomies, achieving a 100% success rate in creating small, large, and thinned windows. A synthetic transparent window was installed after skull excision. This system enables high-quality OCT angiography, velocimetry, and ultrasound imaging, offering an efficient tool for brain research.
- 14 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (5) , 2283-2294
Angle-Independent Blood Flow Velocity Measurement With Ultrasound Speckle Decorrelation Analysis
Precise measurement of the blood flow velocity in major arteries is important for the assessment of circulation dysfunction but challenging when using a one-dimensional (1D) ultrasound transducer array. Current available ultrasound velocimetry methods are susceptible to the probe-to-vessel angle and require the vessels to be well-aligned within the imaging plane of the 1D transducer array. In this study, a novel angle-independent velocimetry (VT-vUS) based on the ultrasound speckle decorrelation analysis of the ultrasound field signal is proposed to measure the blood flow velocity using a conventional 1D ultrasound transducer array. We first introduced the principle and evaluated this technique with numerical simulation and phantom experiments, which demonstrated that VT-vUS can accurately reconstruct the velocity magnitude of blood flow at arbitrary probe-to-vessel angles for different preset flow speeds (up to ~2.5 m/s). Further, we applied VT-vUS to measure the pulsatile flow of the radial artery and carotid artery in a healthy volunteer. Results show that the absolute velocity profiles obtained with VT-vUS at different probe-to-vessel angles have high consistency and agree well with the absolute speed obtained with the color Doppler-corrected velocimetry throughout the cardiac cycle. With the ability to alleviate the dependency on probe-to-vessel angle, VT-vUS has the potential for circulation-related disease screening in clinical practices.
- 14 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (5) , 2283-2294
Angle-Independent Blood Flow Velocity Measurement With Ultrasound Speckle Decorrelation Analysis
Precise measurement of the blood flow velocity in major arteries is important for the assessment of circulation dysfunction but challenging when using a one-dimensional (1D) ultrasound transducer array. Current available ultrasound velocimetry methods are susceptible to the probe-to-vessel angle and require the vessels to be well-aligned within the imaging plane of the 1D transducer array. In this study, a novel angle-independent velocimetry (VT-vUS) based on the ultrasound speckle decorrelation analysis of the ultrasound field signal is proposed to measure the blood flow velocity using a conventional 1D ultrasound transducer array. We first introduced the principle and evaluated this technique with numerical simulation and phantom experiments, which demonstrated that VT-vUS can accurately reconstruct the velocity magnitude of blood flow at arbitrary probe-to-vessel angles for different preset flow speeds (up to ~2.5 m/s). Further, we applied VT-vUS to measure the pulsatile flow of the radial artery and carotid artery in a healthy volunteer. Results show that the absolute velocity profiles obtained with VT-vUS at different probe-to-vessel angles have high consistency and agree well with the absolute speed obtained with the color Doppler-corrected velocimetry throughout the cardiac cycle. With the ability to alleviate the dependency on probe-to-vessel angle, VT-vUS has the potential for circulation-related disease screening in clinical practices.
- 13 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 43 (2) , 638-648
Time-Lagged Functional Ultrasound for Multi-Parametric Cerebral Hemodynamic Imaging
We introduce an ultrasound speckle decorrelation-based time-lagged functional ultrasound technique (tl-fUS) for the quantification of the relative changes in cerebral blood flow speed (rCBF speed ), cerebral blood volume (rCBV) and cerebral blood flow (rCBF) during functional stimulations. Numerical simulations, phantom validations, and in vivo mouse brain experiments were performed to test the capability of tl-fUS to parse out and quantify the ratio change of these hemodynamic parameters. The blood volume change was found to be more prominent in arterioles compared to venules and the peak blood flow changes were around 2.5 times the peak blood volume change during brain activation, agreeing with previous observations in the literature. The tl-fUS shows the ability of distinguishing the relative changes of rCBF speed , rCBV, and rCBF, which can inform specific physiological interpretations of the fUS measurements.
- 13 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 43 (2) , 638-648
Time-Lagged Functional Ultrasound for Multi-Parametric Cerebral Hemodynamic Imaging
We introduce an ultrasound speckle decorrelation-based time-lagged functional ultrasound technique (tl-fUS) for the quantification of the relative changes in cerebral blood flow speed (rCBF speed ), cerebral blood volume (rCBV) and cerebral blood flow (rCBF) during functional stimulations. Numerical simulations, phantom validations, and in vivo mouse brain experiments were performed to test the capability of tl-fUS to parse out and quantify the ratio change of these hemodynamic parameters. The blood volume change was found to be more prominent in arterioles compared to venules and the peak blood flow changes were around 2.5 times the peak blood volume change during brain activation, agreeing with previous observations in the literature. The tl-fUS shows the ability of distinguishing the relative changes of rCBF speed , rCBV, and rCBF, which can inform specific physiological interpretations of the fUS measurements.
- 16 February 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (3) , 1537-1550
Visualization of blood-brain barrier disruption with dual-wavelength high-resolution photoacoustic microscopy
The blood-brain barrier (BBB) strictly regulates the substance exchange between the vascular network and the central nervous system, and plays a critical role in maintaining normal brain homeostasis. Impaired BBB is often accompanied with the emergence of cerebral diseases and probably further leads to severe neuroinflammation or even neurological degeneration. Hence, there is an urgent need to precisely monitor the impaired BBB to understand its pathogenesis and better guide the enactment of therapeutic strategies. However, there is a lack of high-resolution imaging techniques to visualize and evaluate the large-scale BBB disruption in pre-clinical and clinical aspects. In this study, we propose a dual-wavelength photoacoustic imaging (PAI) methodology that simultaneously reveals the abnormal microvasculature and impaired BBB within the cerebral cortex. In in vivo studies, BBB disruption in both mice and rats were induced by local hot-water stimulation and unilateral carotid arterial perfusion of hyperosmolar mannitol, respectively. Subsequently, the exogenous contrast agent (CA) was injected into the microcirculation via the tail vein, and photoacoustic (PA) images of the microvasculature and leaked CA within the cerebral cortex were obtained by dual-wavelength photoacoustic microscopy to evaluate the BBB disruption. Besides, analysis of distribution and concentration of leaked CA in lesion region was further conducted to quantitatively reveal the dynamic changes of BBB permeability. Furthermore, we exploited this approach to investigate the reversibility of BBB disruption within the two distinct models. Based on the experimental results, this new proposed approach presents excellent performance in visualizing microvasculature and leaked CA, and enabling it possesses great potential in evaluating the abnormal microvasculature and impaired BBB result from cerebrovascular diseases.
- 16 February 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (3) , 1537-1550
Visualization of blood-brain barrier disruption with dual-wavelength high-resolution photoacoustic microscopy
The blood-brain barrier (BBB) strictly regulates the substance exchange between the vascular network and the central nervous system, and plays a critical role in maintaining normal brain homeostasis. Impaired BBB is often accompanied with the emergence of cerebral diseases and probably further leads to severe neuroinflammation or even neurological degeneration. Hence, there is an urgent need to precisely monitor the impaired BBB to understand its pathogenesis and better guide the enactment of therapeutic strategies. However, there is a lack of high-resolution imaging techniques to visualize and evaluate the large-scale BBB disruption in pre-clinical and clinical aspects. In this study, we propose a dual-wavelength photoacoustic imaging (PAI) methodology that simultaneously reveals the abnormal microvasculature and impaired BBB within the cerebral cortex. In in vivo studies, BBB disruption in both mice and rats were induced by local hot-water stimulation and unilateral carotid arterial perfusion of hyperosmolar mannitol, respectively. Subsequently, the exogenous contrast agent (CA) was injected into the microcirculation via the tail vein, and photoacoustic (PA) images of the microvasculature and leaked CA within the cerebral cortex were obtained by dual-wavelength photoacoustic microscopy to evaluate the BBB disruption. Besides, analysis of distribution and concentration of leaked CA in lesion region was further conducted to quantitatively reveal the dynamic changes of BBB permeability. Furthermore, we exploited this approach to investigate the reversibility of BBB disruption within the two distinct models. Based on the experimental results, this new proposed approach presents excellent performance in visualizing microvasculature and leaked CA, and enabling it possesses great potential in evaluating the abnormal microvasculature and impaired BBB result from cerebrovascular diseases.