A Novel Device for Measurement of Subglottic Stenosis in 3 Dimensions During Suspension Laryngoscopy
Authors:
Open Access
- 1 April 2015
- journal article
- Published by American Medical Association (AMA) in JAMA Otolaryngology–Head & Neck Surgery
- Vol. 141 (4) , 377-381
Abstract
Importance A challenge in treating subglottic stenosis is assessment of airway caliber before and after management. At present, surgeons lack a simple, efficient, and precise method of measuring subglottic stenosis intraoperatively. We present a novel, easily reproducible tool for measurement of the diameter, location, and length of subglottic stenosis during suspension laryngoscopy. Methods and Observations A set of 5 Kirschner wires (30-cm length and 1.6-mm diameter) were bent 90° at both ends to produce a series of 10 short ends designed to measure airway diameter (0.3- to 2.1-cm length with 2-mm intervals). Short, bent ends of the measuring sticks were designed to measure airway diameter. Hash marks at 2-mm intervals were created along the long axis of the measuring sticks to measure subglottic stenosis length and location relative to the vocal cords. The measuring stick was tested in 10 adult patients undergoing suspension microlaryngoscopy for endoscopic treatment of subglottic stenosis between September 2012 and July 2013. The accuracy of the measuring stick was evaluated using an airway phantom. The measuring stick enabled easy and precise quantification of subglottic stenosis diameter (82.5% agreement with reference; interobserver agreement,r = 0.995;P < .001), length (72.5%;r = 0.995;P < .001) and location during suspension laryngoscopy. Conclusions and Relevance The measuring stick is inexpensive and simple to construct. It allows for safe, accurate, and practical measurement of subglottic stenosis diameter, length, and location during suspension laryngoscopy.Keywords
This publication has 11 references indexed in Scilit:
- Multiplanar 3D ultrasound imaging to assess the anatomy of the upper airway and measure the subglottic and tracheal diameters in adultsBritish Journal of Radiology, 2013
- Measuring airway dimensions during bronchoscopy using anatomical optical coherence tomographyEuropean Respiratory Journal, 2009
- Computed Tomography — An Increasing Source of Radiation ExposureNew England Journal of Medicine, 2007
- Assessment of Airway Caliber in Quantitative VideobronchoscopyRespiration, 2006
- Airway dimensions measured from micro-computed tomography and high-resolution computed tomographyEuropean Respiratory Journal, 2006
- Objective Sizing of Upper Airway Stenosis: A Quantitative Endoscopic ApproachThe Laryngoscope, 2006
- Quantification of the magnification and distortion effects of a pediatric flexible video-bronchoscopeRespiratory Research, 2005
- Subglottic Stenosis: Correlation between Computed Tomography and BronchoscopyAnnals of Otology, Rhinology & Laryngology, 1999
- Calibration of Endoscopic ImagesAnnals of Otology, Rhinology & Laryngology, 1995
- Proposed Grading System for Subglottic Stenosis Based on Endotracheal Tube SizesAnnals of Otology, Rhinology & Laryngology, 1994