Safely assessing radiofrequency heating potential of conductive devices using image‐based current measurements
Open Access
- 22 January 2014
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 73 (1) , 427-441
Abstract
Purpose: Many procedures involving catheters and implanted medical devices could benefit from MRI guidance but are currently contraindicated due to risk of significant heating near linear conductive structures. A priori safety prediction is impossible in vivo and thus, safety is typically investigated in vitro by directly measuring temperature rise. Existing methods of investigating safety are inflexible and provide few data. Furthermore, they are fundamentally limited because dangerous temperatures rises can only be investigated if induced. A method of remotely predicting safety is necessary for ensuring safety in patients.Theory and Methods: Electric current induced on the metallic object causes any dangerous heating; thus a remote method of safely characterizing the induced radiofrequency (RF) current distribution would suffice to evaluate safety assuming conservative estimates for local tissue properties. Here we propose a method of analyzing induced phase artifacts seen in low‐specific absorption rate characterization images, to determine induced current on an interventional device. This induced current distribution can then be used to predict RF heating behavior under application of any other imaging sequence.Results: This method has been successfully used to reproduce numerical simulations in a phantom. Furthermore, the heating behavior around a conductive wire produced by a scan other than that used to characterize current was successfully predicted.Conclusion: It has been shown in phantom experiments that remote current characterization can safely prevent dangerous scans as well as enable safe scans that previously would not have been attempted. Magn Reson Med 73:427–441, 2015.Keywords
This publication has 31 references indexed in Scilit:
- Determining the risks of clinically indicated nonthoracic magnetic resonance imaging at 1.5 T for patients with pacemakers and implantable cardioverter-defibrillators: Rationale and design of the MagnaSafe RegistryAmerican Heart Journal, 2013
- Reduction of implant RF heating through modification of transmit coil electric fieldMagnetic Resonance in Medicine, 2010
- Forward‐looking intravascular orthogonal‐solenoid coil for imaging and guidance in occlusive arterial diseaseMagnetic Resonance in Medicine, 2008
- An overview on the advances in cardiovascular interventional MR imagingMagnetic Resonance Materials in Physics, Biology and Medicine, 2007
- Percutaneous Recanalization of Chronically Occluded Coronary ArteriesCirculation, 2005
- Percutaneous Recanalization of Chronically Occluded Coronary ArteriesCirculation, 2005
- Transmission line for improved RF safety of interventional devicesMagnetic Resonance in Medicine, 2005
- Reduction of resonant RF heating in intravascular catheters using coaxial chokesMagnetic Resonance in Medicine, 2000
- A precise and fast temperature mapping using water proton chemical shiftMagnetic Resonance in Medicine, 1995
- Noninvasive MRI Thermometry with the Proton Resonance Frequency (PRF) Method: In Vivo Results in Human MuscleMagnetic Resonance in Medicine, 1995