A self-made, low-cost infrared system for evaluating the sciatic functional index in mice
Open Access
- 1 January 2016
- journal article
- research article
- Published by Medknow in Neural Regeneration Research
- Vol. 11 (5) , 829-834
Abstract
The sciatic functional index (SFI) is a popular parameter for peripheral nerve evaluation that relies on footprints obtained with ink and paper. Drawbacks include smearing artefacts and a lack of dynamic information during measurement. Modern applications use digitized systems that can deliver results with less analytical effort and fewer mice. However, the systems are expensive (€40,000). This study aimed to evaluate the applicability and precision of a self-made, low-cost infrared system for evaluating SFI in mice. Mice were subjected to unilateral sciatic nerve crush injury (crush group; n = 7) and sham operation (sham group; n = 4). They were evaluated on the day before surgery, the 2 nd , 4 th and 6 th days after injury, and then every day up to the 23 rd day after injury. We compared two SFI evaluation methods, i.e., conventional ink-and-paper SFI (C-SFI) and our infrared system (I-SFI). Our apparatus visualized footprints with totally internally reflected infrared light (950 nm) and a camera that can only detect this wavelength. Additionally we performed an analysis with the ladder beam walking test (LBWT) as a reference test. I-SFI assessment reduced the standard deviation by about 33 percent, from 11.6 to 7.8, and cut the variance around the baseline to 21 percent. The system thus requires fewer measurement repetitions and fewer animals, and cuts the cost of keeping the animals. The apparatus cost €321 to build. Our results show that the process of obtaining the SFI can be made more precise via digitization with a self-made, low-cost infrared system.Keywords
This publication has 22 references indexed in Scilit:
- Modification of the Ladder Rung Walking Task—New Options for Analysis of Skilled MovementsStroke Research and Treatment, 2013
- Nerve grafts with various sensory and motor fiber compositions are equally effective for the repair of a mixed nerve defectExperimental Neurology, 2010
- The Ladder Rung Walking Task: A Scoring System and its Practical Application.Journal of Visualized Experiments, 2009
- Electrophysiologic assessment of sciatic nerve regeneration in the rat: Surrounding limb muscles feature strongly in recordings from the gastrocnemius muscleJournal of Neuroscience Methods, 2007
- Adaptation of a ladder beam walking task to assess locomotor recovery in mice following spinal cord injuryBehavioural Brain Research, 2007
- Impacts of lesion severity and tyrosine kinase receptor B deficiency on functional outcome of femoral nerve injury assessed by a novel single‐frame motion analysis in miceEuropean Journal of Neuroscience, 2005
- Effects of motor versus sensory nerve grafts on peripheral nerve regenerationExperimental Neurology, 2004
- Sciatic nerve regeneration in mice and rats: recovery of sensory innervation is followed by a slowly retreating neuropathic pain-like syndromeBrain Research, 2004
- Functional Evaluation of Complete Sciatic, Peroneal, and Posterior Tibial Nerve Lesions in the RatPlastic and Reconstructive Surgery, 1989
- An index of the functional condition of rat sciatic nerve based on measurements made from walking tracksExperimental Neurology, 1982