Cytokine adsorption properties of a polymethylmethacrylate (PMMA) hollow-fiber membrane: an in vitro study
Open Access
- 15 November 2025
- journal article
- research article
- Published by Springer Nature in Renal Replacement Therapy
- Vol. 11 (1) , 92
Abstract
Background: The aims of this study were to analyze the relationship between the membrane surface area and cytokine adsorption performance of polymethylmethacrylate (PMMA) hemofilters as well as the distribution of cytokines inside the membrane after contact with a cytokine. Methods: Briefly, 1 L of bovine plasma with interleukin (IL)-6 was circulated through four types of PMMA hemofilters with different membrane surface areas (0.3, 0.6, 1.3, and 1.8 m 2 ) without dialysis and filtration, and changes in the IL-6 concentration in the plasma were observed. In addition, mini-modules comprising PMMA hollow fibers were circulated in an IL-6 solution for 24 h, and the distribution of IL-6 in the PMMA membrane was inferred by detecting the secondary ion image of 12 C 14 N − , which reflects nitrogen-containing organic compounds (in this case, IL-6), using a nanoscale secondary ion mass spectrometer (NanoSIMS). Results: After 24 h of circulation, the IL-6 removal rates for hemofilters with membrane surface areas of 0.3, 0.6, 1.3, and 1.8 m 2 were 74%, 84%, 89%, and 89%, respectively. The times required to reduce the initial concentration by 50% were 486 ± 25 min, 175 ± 16 min, 104 ± 6.7 min, and 88 ± 20 min, respectively ( p < 0.01). Using a 1.8 m 2 hemofilter, in vitro circulation tests for IL-8, IL-10, and tumor necrosis factor (TNF)- α showed removal rates of 87%, 85%, and 54%, respectively, at 4 h. The observed 12 C 14 N − signal indicates a possible distribution of IL-6 across the PMMA hollow-fiber membrane from the blood side to the dialysate side after the IL-6 solution was circulated through the mini-module for 24 h. Conclusion: PMMA hemofilters rapidly adsorbed IL-6 in an in vitro circulation test, depending on the membrane surface area. IL-8, IL-10, and TNF- α were also removed. IL-6 was inferred to permeate the PMMA membrane and be widely adsorbed throughout the membrane.Keywords
This publication has 14 references indexed in Scilit:
- Comprehensive analysis of cytokine adsorption properties of polymethyl methacrylate (PMMA) membrane materialJournal of Artificial Organs, 2022
- Immunotoxicology of Biopharmaceutics2018
- NanoSIMS for biological applications: Current practices and analysesBiointerphases, 2017
- Cytokine storm and sepsis disease pathogenesisSeminars in Immunopathology, 2017
- The Third International Consensus Definitions for Sepsis and Septic Shock (Sepsis-3)JAMA, 2016
- Efficacy of Series Double Continuous Hemodiafiltration Using Two Polymethyl Methacrylate Membrane Hemofilters for Patients With HypercytokinemiaTherapeutic Apheresis and Dialysis, 2013
- Investigation of the freely available easy-to-use software ‘EZR’ for medical statisticsBone Marrow Transplantation, 2012
- Comparison of Interleukin-6 Removal Properties among Hemofilters Consisting of Varying Membrane Materials and Surface Areas: An in vitro StudyBlood Purification, 2010
- Current Topics on Cytokine Removal TechnologiesTherapeutic Apheresis, 2001
- Effects of different doses in continuous veno-venous haemofiltration on outcomes of acute renal failure: a prospective randomised trialThe Lancet, 2000