Improving the Model Migration Ability by a Hyperspectral Method With a High Spatial Resolution
Open Access
- 25 November 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 171260-171271
Abstract
In the spectral analysis of a complex solution, the model migration ability is a key challenge. The influence of changes in external factors (measurement environmental changes) is the main reason for the poor model migration ability. If this influence is not well suppressed, it may affect the model migration ability and reduce the robustness of the model. Therefore, effectively suppressing this influence can enhance the model migration ability and improve accuracy. In this paper, we employ the spatial and time domains in addition to the wavelength domain and propose a high-spatial-resolution hyperspectral method that transforms the information of the external factor changes in the spectrum into DC (direct-current) components in the spatial and time domains. Consequently, the information of the external factor changes is separated from the effective information of the tested substance. An algorithm is proposed to extract parameter spectra that are only related to the information of the tested substance. Then, the traditional transmission spectra are replaced by the extracted parameter spectra in the modeling. We design an experiment to spectrally analyze hemoglobin (HB), and two kinds of measurement containers are used to simulate a type of external factor. To verify the effectiveness of the proposed method, we determine whether the model can be migrated to an environment with a different measurement container. The experimental results show that the prediction accuracy for HB and the model migration ability are satisfactory. The results indicate that the high-spatial-resolution hyperspectral method can effectively suppress the influence of external factor changes on spectral analysis and improve the model migration ability.Keywords
This publication has 31 references indexed in Scilit:
- Evaluation of Sugar Content of Potatoes using Hyperspectral ImagingFood and Bioprocess Technology, 2015
- Simultaneous determination of glucose, triglycerides, urea, cholesterol, albumin and total protein in human plasma by Fourier transform infrared spectroscopy: Direct clinical biochemistry without reagentsClinical Biochemistry, 2014
- Efficiency of radiation protection equipment in interventional radiology: a systematic Monte Carlo study of eye lens and whole body dosesJournal of Radiological Protection, 2014
- An extension to the discriminant analysis of near-infrared spectraMedical Engineering & Physics, 2012
- Rapid identification and assay of crude oils based on moving-window correlation coefficient and near infrared spectral libraryChemometrics and Intelligent Laboratory Systems, 2011
- The Accuracy of Noninvasive and Continuous Total Hemoglobin Measurement by Pulse CO-Oximetry in Human Subjects Undergoing HemodilutionAnesthesia & Analgesia, 2010
- Comparative analysis of three chemometric techniques for the spectroradiometric assessment of canopy chlorophyll content in winter wheatComputers and Electronics in Agriculture, 2010
- Pulse glucometry: a new approach for noninvasive blood glucose measurement using instantaneous differential near-infrared spectrophotometryJournal of Biomedical Optics, 2006
- Anemia and Change in Hemoglobin Over Time Related to Mortality and Morbidity in Patients With Chronic Heart FailureCirculation, 2005
- EPO–PLS external parameter orthogonalisation of PLS application to temperature-independent measurement of sugar content of intact fruitsChemometrics and Intelligent Laboratory Systems, 2003