A major challenge in a Photovoltaic (PV) system is to identify the line-to-line (LL) faults that occurred under low irradiance conditions, during day-to-night/night-to-day transitions in the presence of blocking diodes. Due to active maximum power point tracker, these faults may not be identified and continue to be hidden even if the system returns to a high irradiance condition, since the magnitude of fault current may be less than the rating of the protection device (fuse). Those uncleared faults may subsequently lead to reduced peak output power, reliability issues and may even cause fire risks. To address these issues, a method is proposed to identify the pre-existing/undetected faults using the transitory conditions that occur during the pre-turn ON/OFF condition of the PV inverter (checking mode). From these transitory conditions, the I-V curve of the PV array is exploited without the need for additional components or sensors. Also, there is no need to disconnect the PV array from the setup. Moreover, the local minima is tracked, to discriminate the faults and partial shading conditions. The proposed algorithm is tested on a small-scale grid-connected PV system and implemented in LabVIEW. The results demonstrate the efficacy of proposed algorithm in detecting the pre-existing/undetected faults.Keywords
Funding Information
- Ministry of Electronics and Information technology
This publication has 30 references indexed in Scilit:
- Degradation of multicrystalline silicon solar cells and modules after illumination at elevated temperatureSolar Energy Materials and Solar Cells, 2015
- Photovoltaic Energy Conversion System Fault Detection Using Fractional-Order Color Relation Classifier in Microdistribution SystemsIEEE Transactions on Smart Grid, 2015
- Online Two-Section PV Array Fault Diagnosis With Optimized Voltage Sensor LocationsIEEE Transactions on Industrial Electronics, 2015
- Fault Diagnosis of Photovoltaic Panels Using Dynamic Current–Voltage CharacteristicsIEEE Transactions on Power Electronics, 2015
- Photovoltaic Hot-Spot Detection for Solar Panel Substrings Using AC Parameter CharacterizationIEEE Transactions on Power Electronics, 2015
- DC-link input EMI filter design in a centralized architecture PV inverter: Impedance approach2014
- Line–Line Fault Analysis and Protection Challenges in Solar Photovoltaic ArraysIEEE Transactions on Industrial Electronics, 2012
- A simple model of PV system performance and its use in fault detectionSolar Energy, 2010
- Comprehensive Approach to Modeling and Simulation of Photovoltaic ArraysIEEE Transactions on Power Electronics, 2009
- Fault finding in a 1 MW photovoltaic plant by reflectometry2002