Brad Lehman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Brad Lehman has a total of 82 co-authors. Here are the top co-authors by number of shared publications:
- Mahshid Amirabadi
Electrical and Computer Engineering Department, Northeastern University, Boston, MA, USA
7 shared publications - Yuan Li
Department of Electrical and Computer Engineering, University of Pittsburgh, Pittsburgh, PA, USA
4 shared publications - Chokkalingam Bharatiraja
Department of Electrical Electronics Engineering, Centre for Electric Mobility, SRM Institute of Science and Technology, Kattankulathur, Tamil Nadu, India
3 shared publications - Fang Zheng Peng
Department of Electrical and Computer Engineering, University of Pittsburgh, Pittsburgh, PA, USA
3 shared publications - Guanlin Li
School of Electrical Engineering, Dalian University of Technology, Dalian 116024, China
3 shared publications - Henry Shu-Hung Chung
City University of Hong Kong
3 shared publications
Latest Publications
- 27 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. PP (4) , 1
A Novel Control Strategy for Grid-connected Cascaded Multilevel Inverters Improving Resilience with Flexible Neutral Shift
The asymmetric operation of a grid-connected three-phase cascaded multilevel inverter (CMI) system can significantly degrade grid current quality. Traditional solutions typically rely on hardware redundancy or complex zero-sequence injection to mitigate voltage imbalance, but these methods increase system cost or complexity. This paper proposes a flexible fault-tolerant control strategy based on adaptive shifting of the inverter’s output neutral point. After a fault, this strategy enables all phases to share the voltage deficit in the faulty phase, ensuring symmetric line-to-line voltages and balanced grid currents. A complete inner-loop current control is developed using internal modulation-based feedforward to improve steady-state tracking performance and reduce reliance on real-time PCC/grid voltage sensing. Theoretical modeling and closed-loop analysis are presented. Simulation and experimental results validate the effectiveness of the proposed strategy under fault-tolerant scenarios, demonstrating its suitability for resilient operation in CMI-based grid-connected applications.
- 27 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. PP (4) , 1
A Novel Control Strategy for Grid-connected Cascaded Multilevel Inverters Improving Resilience with Flexible Neutral Shift
The asymmetric operation of a grid-connected three-phase cascaded multilevel inverter (CMI) system can significantly degrade grid current quality. Traditional solutions typically rely on hardware redundancy or complex zero-sequence injection to mitigate voltage imbalance, but these methods increase system cost or complexity. This paper proposes a flexible fault-tolerant control strategy based on adaptive shifting of the inverter’s output neutral point. After a fault, this strategy enables all phases to share the voltage deficit in the faulty phase, ensuring symmetric line-to-line voltages and balanced grid currents. A complete inner-loop current control is developed using internal modulation-based feedforward to improve steady-state tracking performance and reduce reliance on real-time PCC/grid voltage sensing. Theoretical modeling and closed-loop analysis are presented. Simulation and experimental results validate the effectiveness of the proposed strategy under fault-tolerant scenarios, demonstrating its suitability for resilient operation in CMI-based grid-connected applications.
- Open Access
- 1 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 7, 1-27
Life Extension of Lithium-Ion Battery: Degradation Comprehension, Modeling, Characterization, and Mitigation Strategies
The growing demand for lithium-ion batteries (LIBs) in applications ranging from consumer electronics to electric vehicles underscores the need to extend their lifespan and ensure optimal performance. Achieving this requires a deep understanding of LIB degradation, which arises from complex chemical and physical interactions. This article provides a systematic overview of degradation mechanisms, aging models, characterization techniques, and mitigation strategies. It examines key degradation modes, their triggers, and empirical aging models for both cycling and idle conditions, while also analyzing their inter-dependencies. Common characterization techniques are reviewed and compared for their effectiveness in identifying and quantifying degradation, followed by a discussion of key precursors that are vital for early detection of catastrophic failures. Finally, the study explores operational strategies to mitigate degradation and highlights promising charging schemes for lifespan extension of LIBs.
- 1 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 7, 1-27
Open AccessLife Extension of Lithium-Ion Battery: Degradation Comprehension, Modeling, Characterization, and Mitigation Strategies
The growing demand for lithium-ion batteries (LIBs) in applications ranging from consumer electronics to electric vehicles underscores the need to extend their lifespan and ensure optimal performance. Achieving this requires a deep understanding of LIB degradation, which arises from complex chemical and physical interactions. This article provides a systematic overview of degradation mechanisms, aging models, characterization techniques, and mitigation strategies. It examines key degradation modes, their triggers, and empirical aging models for both cycling and idle conditions, while also analyzing their inter-dependencies. Common characterization techniques are reviewed and compared for their effectiveness in identifying and quantifying degradation, followed by a discussion of key precursors that are vital for early detection of catastrophic failures. Finally, the study explores operational strategies to mitigate degradation and highlights promising charging schemes for lifespan extension of LIBs.
- 8 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (12) , 12118-12125
Resilient Operation for Grid-Connected Cascaded H-Bridge Multilevel Inverter Based on Neutral Offset
In power systems increasingly dominated by renewable energy generations, cascaded H-bridge (CHB) multilevel inverters are well-suited for high-power applications. However, CHB topologies are prone to unbalanced conditions due to submodule faults. While redundant submodules are commonly employed to mitigate these issues, they lower efficiency and increase the costs and complexity of circuits. This article addresses unbalanced grid currents caused by faulty submodules in CHB inverters through a neutral point-shifting control strategy. When submodules are bypassed due to faults, all remaining submodules, across both normal and faulty phases, share the lost voltage of the bypassed submodules. The corresponding control strategy is presented in this article, constraints and source voltage stress reduction are analyzed, and the effectiveness is verified by simulation and experimental tests. The proposed method can reduce system costs and downtime, thus enhancing the resilient operation of the entire system.
- 8 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (12) , 12118-12125
Resilient Operation for Grid-Connected Cascaded H-Bridge Multilevel Inverter Based on Neutral Offset
In power systems increasingly dominated by renewable energy generations, cascaded H-bridge (CHB) multilevel inverters are well-suited for high-power applications. However, CHB topologies are prone to unbalanced conditions due to submodule faults. While redundant submodules are commonly employed to mitigate these issues, they lower efficiency and increase the costs and complexity of circuits. This article addresses unbalanced grid currents caused by faulty submodules in CHB inverters through a neutral point-shifting control strategy. When submodules are bypassed due to faults, all remaining submodules, across both normal and faulty phases, share the lost voltage of the bypassed submodules. The corresponding control strategy is presented in this article, constraints and source voltage stress reduction are analyzed, and the effectiveness is verified by simulation and experimental tests. The proposed method can reduce system costs and downtime, thus enhancing the resilient operation of the entire system.
- Open Access
- 12 March 2025
- Published by Associacao Brasileira de Eletronica de Potencia SOBRAEP in Eletrônica de Potência
- Vol. 30, e202525
48 V to 1 V DC-DC Converter Based on Cascade/Ladder Connected Switched Capacitor Cells
This paper proposes a cascade/ladder switched capacitor converter integrated with an interleaved synchronous buck converter to provide a 48 V to 1 V conversion for data center applications. The switched capacitor stage decreases the input voltage from 48 V to 3 V (a reduction of 16 times), with low voltage stress on the input switches and intermediate voltage levels that can be used as voltage sources. The interleaved buck stage provides voltage and current control and is connected in cascade with the switched capacitor stage to reduce the voltage from 3 V to 1 V (a reduction of 3 times). Furthermore, a switching frequency optimization is proposed for the switched-capacitor converter to maximize efficiency. The proposed solution was experimentally validated in a two-stage 30 W prototype: the first stage is the proposed cascade/ladder switched capacitor topology (48 V to 3 V) with unregulated conversion, which provides a maximum efficiency of 91,6%, and the second stage is the buck converters (3 V to 1 V) with regulated conversion.
- 12 March 2025
- Published by Associacao Brasileira de Eletronica de Potencia SOBRAEP in Eletrônica de Potência
- Vol. 30, e202525
Open Access48 V to 1 V DC-DC Converter Based on Cascade/Ladder Connected Switched Capacitor Cells
This paper proposes a cascade/ladder switched capacitor converter integrated with an interleaved synchronous buck converter to provide a 48 V to 1 V conversion for data center applications. The switched capacitor stage decreases the input voltage from 48 V to 3 V (a reduction of 16 times), with low voltage stress on the input switches and intermediate voltage levels that can be used as voltage sources. The interleaved buck stage provides voltage and current control and is connected in cascade with the switched capacitor stage to reduce the voltage from 3 V to 1 V (a reduction of 3 times). Furthermore, a switching frequency optimization is proposed for the switched-capacitor converter to maximize efficiency. The proposed solution was experimentally validated in a two-stage 30 W prototype: the first stage is the proposed cascade/ladder switched capacitor topology (48 V to 3 V) with unregulated conversion, which provides a maximum efficiency of 91,6%, and the second stage is the buck converters (3 V to 1 V) with regulated conversion.
- 7 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (2) , 2647-2683
Power Electronic Converters in Inductive Wireless Charging Applications for Electric Transportation
Wireless Charging System (WCS) for Electric Vehicles (EVs) has the potential to revolutionize traditional plug-in charging methods. This technology employs different methods. Among these, Resonant Inductive Power Transfer (R-IPT) stands out in EV applications for its high efficiency and lower operating frequencies compared to others. The role of Power Electronics Converters (PEC) in achieving high frequency and resonance operation is vital, with switches and compensators playing crucial roles in resonant converter design. This article emphasizes the significance of PECs, explores the factors influencing converters selection and their classifications, and provides an overview of various PECs at different stages of Wireless Power Transfer (WPT) systems, along with their characteristics. Additionally, it delves into Wide Bandgap (WBG) devices and different semiconductor switches, discussing their roles in R-IPT systems, as well as their advantages and disadvantages. This paper also outlines the characteristics, features, and limitations of various overview compensation topologies, serving as a valuable resource for researchers seeking to develop new topologies for wireless charging applications. A comprehensive discussion on future challenges, development trends, and prospects is provided.
- 7 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (2) , 2647-2683
Power Electronic Converters in Inductive Wireless Charging Applications for Electric Transportation
Wireless Charging System (WCS) for Electric Vehicles (EVs) has the potential to revolutionize traditional plug-in charging methods. This technology employs different methods. Among these, Resonant Inductive Power Transfer (R-IPT) stands out in EV applications for its high efficiency and lower operating frequencies compared to others. The role of Power Electronics Converters (PEC) in achieving high frequency and resonance operation is vital, with switches and compensators playing crucial roles in resonant converter design. This article emphasizes the significance of PECs, explores the factors influencing converters selection and their classifications, and provides an overview of various PECs at different stages of Wireless Power Transfer (WPT) systems, along with their characteristics. Additionally, it delves into Wide Bandgap (WBG) devices and different semiconductor switches, discussing their roles in R-IPT systems, as well as their advantages and disadvantages. This paper also outlines the characteristics, features, and limitations of various overview compensation topologies, serving as a valuable resource for researchers seeking to develop new topologies for wireless charging applications. A comprehensive discussion on future challenges, development trends, and prospects is provided.
- 18 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power Electronics Magazine
- Vol. 11 (3) , 14-20
Reflecting on Our Journey [President’s Message]
- 18 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power Electronics Magazine
- Vol. 11 (3) , 14-20
Reflecting on Our Journey [President’s Message]
- 16 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (1) , 1053-1068
From Active Resistor to Lossless and Virtual Resistors: A Review, Insights, and Broader Applications to Energy Grids
More-electric and pure-electric ship and aircraft, and electric-grid power systems include three subsystems: generation (generators and inverter-based renewable energy sources), delivery (transmission & distribution lines and cables, transformers, capacitor banks, inductors), and energy storage. Therefore, power systems are dominantly inductive and capacitive. Resistors are rarely used, and circuits are designed and built with minimal resistance to minimize power loss and maximize efficiency. Due to this nature, however, there have been problematic resonances, instability, and prolonged transients. To solve these problems, power converters/inverters were first presented in the 1980s as active, lossless, and virtual resistors to suppress/damp resonances, instability, and transients. In this paper, we provide a comprehensive review of this innovative power converter/inverter-based technology from the active resistor to lossless and virtual resistors. We present theoretical analysis and insights about their interrelationship and physical meanings; discuss their implementation constraints; and examine broader applications and renewed potentials to revolutionize today’s power/energy grids.
- 16 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (1) , 1053-1068
From Active Resistor to Lossless and Virtual Resistors: A Review, Insights, and Broader Applications to Energy Grids
More-electric and pure-electric ship and aircraft, and electric-grid power systems include three subsystems: generation (generators and inverter-based renewable energy sources), delivery (transmission & distribution lines and cables, transformers, capacitor banks, inductors), and energy storage. Therefore, power systems are dominantly inductive and capacitive. Resistors are rarely used, and circuits are designed and built with minimal resistance to minimize power loss and maximize efficiency. Due to this nature, however, there have been problematic resonances, instability, and prolonged transients. To solve these problems, power converters/inverters were first presented in the 1980s as active, lossless, and virtual resistors to suppress/damp resonances, instability, and transients. In this paper, we provide a comprehensive review of this innovative power converter/inverter-based technology from the active resistor to lossless and virtual resistors. We present theoretical analysis and insights about their interrelationship and physical meanings; discuss their implementation constraints; and examine broader applications and renewed potentials to revolutionize today’s power/energy grids.
- 27 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power Electronics Magazine
- Vol. 11 (2) , 10-12
Powering Society’s Progress Together [President’s Message]
Exciting News! The IEEE Power Electronics Society (PELS) has just launched its revamped website at www.ieee-pels.org . After over a year of dedicated work, involving significant contributions from numerous volunteers on the publicity committee - Helen Cui, Rakesh Kumar, Dong Cao, Yuan Li, and Bright Tetteth - and the diligent effots of PELS staff members Mike Kelly and Jessica Uherek, we’re thrilled to unveil this updated platform. The countless hours invested in this project have certainly paid off, evident in the substantial improvements over the previous site, which I always admired. Our aim is to establish the PELS website as the premier destination for all things related to power electronics. This new iteration marks the initial stride towards achieving that goal, with ongoing plans to enhance its functionality in the future.
- 27 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power Electronics Magazine
- Vol. 11 (2) , 10-12
Powering Society’s Progress Together [President’s Message]
Exciting News! The IEEE Power Electronics Society (PELS) has just launched its revamped website at www.ieee-pels.org . After over a year of dedicated work, involving significant contributions from numerous volunteers on the publicity committee - Helen Cui, Rakesh Kumar, Dong Cao, Yuan Li, and Bright Tetteth - and the diligent effots of PELS staff members Mike Kelly and Jessica Uherek, we’re thrilled to unveil this updated platform. The countless hours invested in this project have certainly paid off, evident in the substantial improvements over the previous site, which I always admired. Our aim is to establish the PELS website as the premier destination for all things related to power electronics. This new iteration marks the initial stride towards achieving that goal, with ongoing plans to enhance its functionality in the future.
- 20 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (8) , 9777-9792
Parallel Capacitive-Link Universal Converters With Low Current Stress and High Efficiency
Series capacitive-link universal converters are a relatively new class of single-stage power converters that offer numerous advantages including high reliability, high power density, and high efficiency. However, one of the limitations of these converters is high current stress of the switches, which lowers their efficiency especially in high current applications. In this paper, a new class of soft-/hard-switched parallel capacitivelink converters is introduced to address this limitation of the series capacitive-link universal converter while keeping its advantages. Apart from providing bidirectional power transfer, the proposed ac–ac converter can implement voltage stepping up/down as well as frequency transformation. A small film capacitor, which is placed in parallel with the input and output switch bridges, is responsible for transferring the power from input towards output. A small inductor can be placed in series with the link capacitor to realize zero-current-switching (ZCS) for all the switches under any load conditions, which lowers the switching losses and reduces EMI. The proposed parallel capacitive-link converter is expected to offer an enhanced efficiency and reduced current stress compared to the series capacitive-link universal converters. In this paper, principles of the operation of the proposed converter are presented, and its performance and advantages are verified by simulation and experiment.
- 20 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (8) , 9777-9792
Parallel Capacitive-Link Universal Converters With Low Current Stress and High Efficiency
Series capacitive-link universal converters are a relatively new class of single-stage power converters that offer numerous advantages including high reliability, high power density, and high efficiency. However, one of the limitations of these converters is high current stress of the switches, which lowers their efficiency especially in high current applications. In this paper, a new class of soft-/hard-switched parallel capacitivelink converters is introduced to address this limitation of the series capacitive-link universal converter while keeping its advantages. Apart from providing bidirectional power transfer, the proposed ac–ac converter can implement voltage stepping up/down as well as frequency transformation. A small film capacitor, which is placed in parallel with the input and output switch bridges, is responsible for transferring the power from input towards output. A small inductor can be placed in series with the link capacitor to realize zero-current-switching (ZCS) for all the switches under any load conditions, which lowers the switching losses and reduces EMI. The proposed parallel capacitive-link converter is expected to offer an enhanced efficiency and reduced current stress compared to the series capacitive-link universal converters. In this paper, principles of the operation of the proposed converter are presented, and its performance and advantages are verified by simulation and experiment.