Shear bond strength of a bracket-bonding system cured with a light-emitting diode or halogen-based light-curing unit at various polymerization times
Open Access
- 1 January 2018
- journal article
- research article
- Published by Taylor & Francis in Clinical, Cosmetic and Investigational Dentistry
- Vol. 10, 61-67
Abstract
Purpose: To determine and compare the shear bond strength (SBS) of bracket-bonding system cured with light-emitting diode (LED) and halogen-based light-curing unit at various polymerization times. Materials and methods: Ninety six human maxillary premolar teeth extracted for orthodontic purpose were divided into four groups, according to the light-curing unit and exposure times used. In the halogen group, the specimens were light cured for 20 and 40 seconds. In the LED group, the specimens were light cured for 5 and 10 seconds. Stainless steel brackets were bonded with Enlight bonding system, stored in distilled water at 37 degrees C for 24 hours and then submitted to SBS testing in a universal testing machine at a crosshead speed of 0.5 mm/minute. Adhesive remnant index (ARI) was used to evaluate the amount of adhesive remaining on the teeth determined by stereomicroscope at 10x magnification. Results: The highest mean SBS was obtained with the halogen 40 seconds (18.27 MPa) followed by halogen 20 seconds (15.36 MPa), LED 10 seconds (14.60 MPa) and least with LED 5 seconds (12.49 MPa) group. According to analysis of variance (ANOVA) and Tukey's multiple-comparison test, SBS of halogen 20 seconds group was not significantly different from halogen 40 seconds group, LED 5 seconds group and LED 10 seconds group, whereas halogen 40 seconds group was significantly different from LED 5 seconds and LED 10 seconds group. The method of light curing did not influence the ARI, with score 2 being predominant. Conclusion: Polymerization with both halogen and LED resulted in SBS values that were clinically acceptable for orthodontic treatment in all groups. Hence, for bonding orthodontic brackets, photoactivation with halogen for 20 seconds and LED for 5 seconds is suggested.Keywords
This publication has 45 references indexed in Scilit:
- A comparative evaluation of the shear bond strength of five different orthodontic bonding agents polymerized using halogen and light-emitting diode curing lights: An in vitro investigationIndian Journal of Dental Research, 2011
- Effect of curing time on the bond strength of a bracket-bonding system cured with a light-emitting diode or plasma arc lightEuropean Journal of Orthodontics, 2010
- In-vitro orthodontic bond strength testing: A systematic review and meta-analysisAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2010
- Influence of different tooth types on the bond strength of two orthodontic adhesive systemsEuropean Journal of Orthodontics, 2008
- Development of a device to measure bracket debonding force in vivoEuropean Journal of Orthodontics, 2007
- Effect of light-tip distance on the shear bond strengths of resin-modified glass ionomer cured with high-intensity halogen, light-emitting diode, and plasma arc lightsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2006
- Light-curing time reduction with a new high-power halogen lampAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2005
- Shear bond strength of orthodontic brackets bonded with light-emitting diode curing units at various polymerization timesAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2004
- Plasma arc versus halogen light curing of orthodontic brackets: a 12-month clinical study of bond failuresAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2004
- The influence of orthodontic bracket base design on shear bond strengthAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2003