Abstract
It is important to achieve sufficiently low joint resistance (RJ) in the ITER TF coil. RJ of TF coil termination is mainly determined by contact resistance between cable and copper sole of the joint box (Rc), and contact resistance between copper sole soldering. The authors first focused on development of inspection method for Rc. Rc affects current penetration length (CPL) between the cable and copper sole. The author thus assumed that when a joint is fabricated with proper process, i.e. Rc is sufficiently low, the behavior of CPL is repeatable. On the other hand, when there is some abnormality in manufactured joint, we can find irregular behavior on CPL compared to the normal repeatable behavior. Thus, authors propose an inspection method in which a current of 20 A is injected in the joint and the voltage profile along the joint is measured at room temperature. As results of the measurement, good repeatability of CPL could be shown in actual all ITER TF joints tested, while significant difference of CPL was observed in a joint sample which includes some disturbances.

This publication has 11 references indexed in Scilit: