Reflection Measurement of the Scattering Mean Free Path at the Onset of Multiple Scattering
- 23 October 2024
- journal article
- research article
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 133 (17) , 176301
Abstract
Multiple scattering of waves presents challenges for imaging complex media but offers potential for their characterization. Its onset is actually governed by the scattering mean free path ℓ_{s} that provides crucial information on the medium microarchitecture. Here, we introduce a reflection matrix method designed to estimate this parameter from the time decay of the single scattering rate. Our method is first validated by an ultrasound experiment on a tissue-mimicking phantom before being applied in vivo to a human liver. This Letter opens important perspectives for quantitative imaging of heterogeneous media with waves, whether it be for nondestructive testing, biomedical, or geophysical applications.Keywords
All Related Versions
Funding Information
- H2020 European Research Council
- Horizon 2020 Framework Programme (819261)
- Agence Nationale de la Recherche (ANR-10-LABX24, ANR-10-IDEX-0001-02 PSL)
This publication has 48 references indexed in Scilit:
- Distribution of seismic scatterers in the San Jacinto Fault Zone, southeast of Anza, California, based on passive matrix imagingEarth and Planetary Science Letters, 2022
- Characterization of the Lung Parenchyma Using Ultrasound Multiple ScatteringUltrasound in Medicine & Biology, 2017
- Individual patient data meta-analysis of controlled attenuation parameter (CAP) technology for assessing steatosisJournal of Hepatology, 2017
- Tomography of crustal seismic attenuation in Metropolitan France: implications for seismicity analysisBulletin of Earthquake Engineering, 2017
- Comparison between experimental and 2-D numerical studies of multiple scattering in Inconel600® by means of array probesUltrasonics, 2014
- Seismic Wave Propagation and Scattering in the Heterogeneous Earth : Second Edition2012
- Controlled Attenuation Parameter (CAP): A Novel VCTE™ Guided Ultrasonic Attenuation Measurement for the Evaluation of Hepatic Steatosis: Preliminary Study and Validation in a Cohort of Patients with Chronic Liver Disease from Various CausesUltrasound in Medicine & Biology, 2010
- Biomedical Optics2009
- Diffuse optical imaging of brain activation: approaches to optimizing image sensitivity, resolution, and accuracyNeuroImage, 2004
- Dependence of ultrasonic attenuation of liver on pathologic fat and fibrosis: Examination with experimental fatty liver and liver fibrosis modelsUltrasound in Medicine & Biology, 1992