William Lambert
William Lambert has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Alexandre Aubry
Institut Langevin ESPCI PSL University CNRS Paris France
3 shared publications - Arthur Le Ber
Institut Langevin
2 shared publications Flavien Bureau
Institut Langevin
2 shared publications- Mathias Fink
Institut Langevin, ESPCI Paris, PSL University, CNRS, Paris, France
2 shared publications - Antton Goïcoechea
Univ Rennes
1 shared publication Arnaud Derode
Institut Langevin
1 shared publication
Latest Publications
- 23 October 2024
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 133 (17) , 176301
Reflection Measurement of the Scattering Mean Free Path at the Onset of Multiple Scattering
Multiple scattering of waves presents challenges for imaging complex media but offers potential for their characterization. Its onset is actually governed by the scattering mean free path ℓ_{s} that provides crucial information on the medium microarchitecture. Here, we introduce a reflection matrix method designed to estimate this parameter from the time decay of the single scattering rate. Our method is first validated by an ultrasound experiment on a tissue-mimicking phantom before being applied in vivo to a human liver. This Letter opens important perspectives for quantitative imaging of heterogeneous media with waves, whether it be for nondestructive testing, biomedical, or geophysical applications.
- 23 October 2024
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 133 (17) , 176301
Reflection Measurement of the Scattering Mean Free Path at the Onset of Multiple Scattering
Multiple scattering of waves presents challenges for imaging complex media but offers potential for their characterization. Its onset is actually governed by the scattering mean free path ℓ_{s} that provides crucial information on the medium microarchitecture. Here, we introduce a reflection matrix method designed to estimate this parameter from the time decay of the single scattering rate. Our method is first validated by an ultrasound experiment on a tissue-mimicking phantom before being applied in vivo to a human liver. This Letter opens important perspectives for quantitative imaging of heterogeneous media with waves, whether it be for nondestructive testing, biomedical, or geophysical applications.
- Top Cited PapersOpen Access
- 25 October 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-13
Three-dimensional ultrasound matrix imaging
Matrix imaging paves the way towards a next revolution in wave physics. Based on the response matrix recorded between a set of sensors, it enables an optimized compensation of aberration phenomena and multiple scattering events that usually drastically hinder the focusing process in heterogeneous media. Although it gave rise to spectacular results in optical microscopy or seismic imaging, the success of matrix imaging has been so far relatively limited with ultrasonic waves because wave control is generally only performed with a linear array of transducers. In this paper, we extend ultrasound matrix imaging to a 3D geometry. Switching from a 1D to a 2D probe enables a much sharper estimation of the transmission matrix that links each transducer and each medium voxel. Here, we first present an experimental proof of concept on a tissue-mimicking phantom through ex-vivo tissues and then, show the potential of 3D matrix imaging for transcranial applications.
- 25 October 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-13
Top Cited PapersOpen AccessThree-dimensional ultrasound matrix imaging
Matrix imaging paves the way towards a next revolution in wave physics. Based on the response matrix recorded between a set of sensors, it enables an optimized compensation of aberration phenomena and multiple scattering events that usually drastically hinder the focusing process in heterogeneous media. Although it gave rise to spectacular results in optical microscopy or seismic imaging, the success of matrix imaging has been so far relatively limited with ultrasonic waves because wave control is generally only performed with a linear array of transducers. In this paper, we extend ultrasound matrix imaging to a 3D geometry. Switching from a 1D to a 2D probe enables a much sharper estimation of the transmission matrix that links each transducer and each medium voxel. Here, we first present an experimental proof of concept on a tissue-mimicking phantom through ex-vivo tissues and then, show the potential of 3D matrix imaging for transcranial applications.
- Open Access
- 1 June 2021
- Published by KEAI Publishing in Animal Nutrition
- Vol. 7 (2) , 472-480
Production performance and plasma metabolite concentrations of broiler chickens fed low crude protein diets differing in Thr and Gly
The aim of the study was to test the interaction between Thr and Gly in low crude protein (CP) diets in 7 to 28 d broilers on production performance and plasma metabolites. A total of 2,040 broilers were allocated to 17 treatments. A positive control (PC) diet (20.5% CP) was formulated to be adequate in dietary Thr and Gly. A negative control (NC) diet (18.5% CP, deficient in Thr and Gly) was supplemented with crystalline l-Thr and Gly to obtain a 4 Thr × 4 Gly design. Dietary Thr was tested at an apparent faecal digestibility (AFD) Thr-to-Lys ratio, which was 55%, 58%, 61% or 64%, and dietary Gly was tested at an AFD (Gly + Ser)-to-Lys ratio, which was 135%, 142%, 149% or 156%. Plasma samples were collected at 28 d. The low CP diet, formulated at 64% Thr and 156% Gly, resulted in a higher body weight gain (BWG) (P < 0.01) and similar feed conversion ratio (FCR) as the high CP treatment (PC). FCR was improved (P < 0.001) by l-Thr supplementation. Quadratic response to dietary Thr was significant for feed intake (FI), BWG and FCR (P < 0.01). A near-significant interaction for Thr × Gly was observed for FI and BWG (Plinear = 0.091 and P = 0.074, respectively). Gly did not affect production performance. An interaction between Thr × Gly on plasma free AA level was observed (P < 0.05). Free AA concentration in plasma linearly decreased with increase in AFD Thr-to-Lys ratio, and increased with increase in AFD (Gly + Ser)-to-Lys ratio. Plasma uric acid concentration was higher in PC than in all of the other diets, and plasma triglyceride concentration was decreased by l-Thr supplementation, but not by Gly. In conclusion, Gly was not limiting for growth at low dietary CP level unless Thr was deficient, showing that adequate amounts of Thr in broiler diets can overcome marginal supply of Gly and Ser and allow reduction of dietary CP from 20.5% to 18.5% for broilers from 7 to 28 d of age.
- 1 June 2021
- Published by KEAI Publishing in Animal Nutrition
- Vol. 7 (2) , 472-480
Open AccessProduction performance and plasma metabolite concentrations of broiler chickens fed low crude protein diets differing in Thr and Gly
The aim of the study was to test the interaction between Thr and Gly in low crude protein (CP) diets in 7 to 28 d broilers on production performance and plasma metabolites. A total of 2,040 broilers were allocated to 17 treatments. A positive control (PC) diet (20.5% CP) was formulated to be adequate in dietary Thr and Gly. A negative control (NC) diet (18.5% CP, deficient in Thr and Gly) was supplemented with crystalline l-Thr and Gly to obtain a 4 Thr × 4 Gly design. Dietary Thr was tested at an apparent faecal digestibility (AFD) Thr-to-Lys ratio, which was 55%, 58%, 61% or 64%, and dietary Gly was tested at an AFD (Gly + Ser)-to-Lys ratio, which was 135%, 142%, 149% or 156%. Plasma samples were collected at 28 d. The low CP diet, formulated at 64% Thr and 156% Gly, resulted in a higher body weight gain (BWG) (P < 0.01) and similar feed conversion ratio (FCR) as the high CP treatment (PC). FCR was improved (P < 0.001) by l-Thr supplementation. Quadratic response to dietary Thr was significant for feed intake (FI), BWG and FCR (P < 0.01). A near-significant interaction for Thr × Gly was observed for FI and BWG (Plinear = 0.091 and P = 0.074, respectively). Gly did not affect production performance. An interaction between Thr × Gly on plasma free AA level was observed (P < 0.05). Free AA concentration in plasma linearly decreased with increase in AFD Thr-to-Lys ratio, and increased with increase in AFD (Gly + Ser)-to-Lys ratio. Plasma uric acid concentration was higher in PC than in all of the other diets, and plasma triglyceride concentration was decreased by l-Thr supplementation, but not by Gly. In conclusion, Gly was not limiting for growth at low dietary CP level unless Thr was deficient, showing that adequate amounts of Thr in broiler diets can overcome marginal supply of Gly and Ser and allow reduction of dietary CP from 20.5% to 18.5% for broilers from 7 to 28 d of age.
- Open Access
- 2 June 2020
- Published by American Physical Society (APS) in Physical Review X
- Vol. 10 (2) , 021048
Reflection Matrix Approach for Quantitative Imaging of Scattering Media
We present a physically intuitive matrix approach for wave imaging and characterization in scattering media. The experimental proof of concept is performed with ultrasonic waves, but this approach can be applied to any field of wave physics for which multielement technology is available. The concept is that focused beam forming enables the synthesis, in transmit and receive, of an array of virtual transducers which map the entire medium to be imaged. The interelement responses of this virtual array form a focused reflection matrix from which spatial maps of various characteristics of the propagating wave can be retrieved. Here we demonstrate (i) a local focusing criterion that enables the image quality and the wave velocity to be evaluated everywhere inside the medium, including in random speckle, and (ii) a highly resolved spatial mapping of the prevalence of multiple scattering, which constitutes a new and unique contrast for ultrasonic imaging. The approach is demonstrated for a controllable phantom system and for in vivo imaging of the human abdomen. More generally, this matrix approach opens an original and powerful route for quantitative imaging in wave physics.
- 2 June 2020
- Published by American Physical Society (APS) in Physical Review X
- Vol. 10 (2) , 021048
Open AccessReflection Matrix Approach for Quantitative Imaging of Scattering Media
We present a physically intuitive matrix approach for wave imaging and characterization in scattering media. The experimental proof of concept is performed with ultrasonic waves, but this approach can be applied to any field of wave physics for which multielement technology is available. The concept is that focused beam forming enables the synthesis, in transmit and receive, of an array of virtual transducers which map the entire medium to be imaged. The interelement responses of this virtual array form a focused reflection matrix from which spatial maps of various characteristics of the propagating wave can be retrieved. Here we demonstrate (i) a local focusing criterion that enables the image quality and the wave velocity to be evaluated everywhere inside the medium, including in random speckle, and (ii) a highly resolved spatial mapping of the prevalence of multiple scattering, which constitutes a new and unique contrast for ultrasonic imaging. The approach is demonstrated for a controllable phantom system and for in vivo imaging of the human abdomen. More generally, this matrix approach opens an original and powerful route for quantitative imaging in wave physics.