Development and Performance Optimization of a Multiplexed DOI-Encoding PET Detector Using the TOFPET2 ASIC
Open Access
- 22 November 2024
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 9 (4) , 395-405
Abstract
Depth-of-interaction (DOI) positron emission tomography (PET) detectors are essential in high-resolution small animal PET. The dual-ended readout detector configuration provides high DOI resolution; however, signal multiplexing schemes are often needed to reduce manufacturing costs. TOFPET2 is a low-cost, multi-channel application-specific integrated circuit (ASIC) designed for individual silicon photomultiplier (SiPM) readout, with performance in multiplexed configurations not well known. This study evaluates a highly multiplexed, high-resolution, dual-ended readout PET detector using TOFPET2. The PET detector was constructed with a 23 × 23 array of LYSO crystals (0.785 × 0.785 × 20 mm) coupled to 6 × 6 SiPM arrays (pitch = 3.3 mm) via 1.2 mm PMMA sheets. Custom boards reduced 72 SiPM signals to 8 (4 per end) before feeding into TOFPET2 channels. The detector was biased at 27, 27.5, and 28 V, with ASIC discriminator thresholds optimised based on flood map quality. Optimal flood maps were obtained at 27.5 V. The mean energy and DOI resolution were 10.5 ± 1.6% and 2.3 ± 0.3 mm, respectively, with a coincidence time resolution (CTR) of 1.3 ns between two detectors. This work demonstrates the feasibility of employing TOFPET2 to achieve high spatial, energy, and DOI resolution in a 9:1 multiplexed system.Keywords
Funding Information
- Australian Research Council (DP190102318)
- Mexican National Council of Humanities, Sciences and Technologies
This publication has 58 references indexed in Scilit:
- Interleaved signal multiplexing readout in depth encoding Prism‐PET detectorsMedical Physics, 2023
- Ultra‐high‐resolution depth‐encoding small animal PET detectors: Using GAGG and LYSO crystal arraysMedical Physics, 2022
- Timing evaluation of a PET detector block based on semi‐monolithic LYSO crystalsMedical Physics, 2021
- Evaluation of high-resolution and depth-encoding PET detector modules based on single-ended readout with TOFPET2 ASICRadiation Detection Technology and Methods, 2021
- Quantitative Rodent Brain Receptor ImagingMolecular Imaging and Biology, 2019
- STIC3 – Silicon Photomultiplier Timing Chip with picosecond resolutionNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2015
- Performance of FBK SiPMs coupled to PETA3 read-out ASIC for PET applicationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2013
- Positron emission tomography (PET) detectors with depth-of- interaction (DOI) capabilityBiomedical Engineering Letters, 2011
- Application of Silicon Photomultipliers to Positron Emission TomographyAnnals of Biomedical Engineering, 2011
- Energy calibration of individual crystals in a LYSO pixelated array for microPET detection modules using Voronoi diagramsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2008