Andre Z. Kyme
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Andre Z. Kyme has a total of 179 co-authors. Here are the top co-authors by number of shared publications:
- Steven Richard Meikle
University of Sydney
52 shared publications - Roger Fulton
Discipline of Medical Imaging Science, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW 2006, Australia
48 shared publications - Clive Baldock
Centre for Medical Radiation Physics, University of Wollongong, Wollongong, Australia
8 shared publications Victor Zhou
Imaging Physics Laboratory, Brain and Mind Centre, The University of Sydney, Sydney, NSW, 2006, Australia
6 shared publications- Francisco E. Enríquez-Mier-Y-Terán
The University of Sydney
5 shared publications Georgios I. Angelis
Imaging Physics Laboratory, Brain and Mind Centre, The University of Sydney, Sydney, NSW, 2006, Australia; Faculty of Health Sciences, The University of Sydney, Sydney, NSW, 2006, Australia
5 shared publications
Latest Publications
- Open Access
- 21 September 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (18) , 185006
Calibration of DOI-capable PET detector panels using uncollimated front-face irradiation
Objective . Gold-standard depth-of-interaction (DOI) calibration using collimated gamma-ray irradiation is time-consuming and requires complex experimental setups, making it impractical for system-level calibration of detector arrays. This work investigates an efficient method for DOI and energy calibration of detector panels using uncollimated irradiation, in which gamma rays are incident parallel, or nearly parallel, to the crystal depth direction. Approach. The 511 keV photopeak location on a dual-ended readout positron emission tomography (PET) detector block as a function of crystal depth was first evaluated using both collimated and uncollimated 22 Na source irradiation to determine whether the latter yields comparable estimates when DOI calibration parameters are known. A 4 × 4 dual-ended readout PET detector panel was then assembled, and three detector blocks were calibrated using the gold-standard method. Two DOI calibration approaches based on uncollimated irradiation—a physics-informed model and a multilayer perceptron (MLP)—were compared against the gold-standard calibration. Finally, the detector panel was calibrated for DOI and energy using the MLP-based approach. Main results . The median relative root mean squared error (RMSE) between second-order polynomial fits to the depth-dependent photopeak location obtained using collimated and uncollimated irradiation was 1%, demonstrating that uncollimated irradiation provides reliable estimates when accurate DOI calibration parameters are available. The RMSE between the gold-standard DOI calibration and the physics-informed and MLP-based approaches ranged from 0.38 to 0.58 mm and 0.36–0.61 mm, respectively, with no statistically significant difference. However, DOI resolution estimates from the MLP-based approach outperformed those of the physics-informed model, favouring its use for full detector panel calibration. After saturation correction, the detector panel achieved a mean energy resolution of 15.6% and a DOI resolution of 2.0 mm. Significance . The proposed MLP-based calibration requires only a single uniform 511 keV source irradiation, making it simple to implement and sufficiently robust for in situ calibration of DOI-capable PET detector arrays.
- 21 September 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (18) , 185006
Open AccessCalibration of DOI-capable PET detector panels using uncollimated front-face irradiation
Objective . Gold-standard depth-of-interaction (DOI) calibration using collimated gamma-ray irradiation is time-consuming and requires complex experimental setups, making it impractical for system-level calibration of detector arrays. This work investigates an efficient method for DOI and energy calibration of detector panels using uncollimated irradiation, in which gamma rays are incident parallel, or nearly parallel, to the crystal depth direction. Approach. The 511 keV photopeak location on a dual-ended readout positron emission tomography (PET) detector block as a function of crystal depth was first evaluated using both collimated and uncollimated 22 Na source irradiation to determine whether the latter yields comparable estimates when DOI calibration parameters are known. A 4 × 4 dual-ended readout PET detector panel was then assembled, and three detector blocks were calibrated using the gold-standard method. Two DOI calibration approaches based on uncollimated irradiation—a physics-informed model and a multilayer perceptron (MLP)—were compared against the gold-standard calibration. Finally, the detector panel was calibrated for DOI and energy using the MLP-based approach. Main results . The median relative root mean squared error (RMSE) between second-order polynomial fits to the depth-dependent photopeak location obtained using collimated and uncollimated irradiation was 1%, demonstrating that uncollimated irradiation provides reliable estimates when accurate DOI calibration parameters are available. The RMSE between the gold-standard DOI calibration and the physics-informed and MLP-based approaches ranged from 0.38 to 0.58 mm and 0.36–0.61 mm, respectively, with no statistically significant difference. However, DOI resolution estimates from the MLP-based approach outperformed those of the physics-informed model, favouring its use for full detector panel calibration. After saturation correction, the detector panel achieved a mean energy resolution of 15.6% and a DOI resolution of 2.0 mm. Significance . The proposed MLP-based calibration requires only a single uniform 511 keV source irradiation, making it simple to implement and sufficiently robust for in situ calibration of DOI-capable PET detector arrays.
- Open Access
- 28 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Artificial Intelligence
- Vol. PP (10) , 1-11
SMPL-GPTexture: Scalable, Training-Free SMPL Texture Synthesis with World Knowledge Transfer from GPT via Geometry-Aware Projection
Texturing 3D human avatars from natural-language prompts remains challenging because generated UV texture maps must be both high-quality and semantically consistent with the prompt. Prior work typically re-trains generative adversarial or diffusion models on curated datasets, which constrain generalization to clothing, stylistic, and cultural variations present in those datasets. To address these limitations, we present SMPL-GPTexture, a training-free pipeline that leverages the rich world knowledge of a pre-trained GPT model to synthesize SMPL human textures. Given a tailored natural-language prompt, GPT- 4o generates geometry-consistent front/back views; we fit SMPL to each view, and invert-rasterize colours into canonical UV space with a geometry-aware view-quality weight, and close remaining gaps with diffusion-based inpainting. On a 550-prompt benchmark, SMPL-GPTexture achieves +17.6% CLIP similarity and +22.4% BLIP improvement over state-of-the-art text-to-texture methods while reducing visible seam artifacts. It generalizes to diverse scenarios such as fantasy avatars, stylized body art, and specialized uniforms without domain-specific finetuning. This facilitates the generation of high-quality textures that surpass current text-to-texture pipelines for fashion prototyping, AR telepresence and digital asset generation. We open-source a UV texture map dataset that covers 23 artistic styles, 49 professions, 19 ethnicities, and 67 clothing descriptors, and a set of easily adaptable prompt templates that can be repurposed to generate any desired texture, fostering research on prompt-driven avatar appearance. The code, sample dataset and prompts will be available at https://github.com/DavidTu21/SMPL-GPTexture.
- 28 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Artificial Intelligence
- Vol. PP (10) , 1-11
Open AccessSMPL-GPTexture: Scalable, Training-Free SMPL Texture Synthesis with World Knowledge Transfer from GPT via Geometry-Aware Projection
Texturing 3D human avatars from natural-language prompts remains challenging because generated UV texture maps must be both high-quality and semantically consistent with the prompt. Prior work typically re-trains generative adversarial or diffusion models on curated datasets, which constrain generalization to clothing, stylistic, and cultural variations present in those datasets. To address these limitations, we present SMPL-GPTexture, a training-free pipeline that leverages the rich world knowledge of a pre-trained GPT model to synthesize SMPL human textures. Given a tailored natural-language prompt, GPT- 4o generates geometry-consistent front/back views; we fit SMPL to each view, and invert-rasterize colours into canonical UV space with a geometry-aware view-quality weight, and close remaining gaps with diffusion-based inpainting. On a 550-prompt benchmark, SMPL-GPTexture achieves +17.6% CLIP similarity and +22.4% BLIP improvement over state-of-the-art text-to-texture methods while reducing visible seam artifacts. It generalizes to diverse scenarios such as fantasy avatars, stylized body art, and specialized uniforms without domain-specific finetuning. This facilitates the generation of high-quality textures that surpass current text-to-texture pipelines for fashion prototyping, AR telepresence and digital asset generation. We open-source a UV texture map dataset that covers 23 artistic styles, 49 professions, 19 ethnicities, and 67 clothing descriptors, and a set of easily adaptable prompt templates that can be repurposed to generate any desired texture, fostering research on prompt-driven avatar appearance. The code, sample dataset and prompts will be available at https://github.com/DavidTu21/SMPL-GPTexture.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- p. 1-11
MR Safe Hydraulic Continuous Actuators With Sinusoidal-Tooth Stepper Drive
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- p. 1-11
Open AccessMR Safe Hydraulic Continuous Actuators With Sinusoidal-Tooth Stepper Drive
- Open Access
- 22 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 9 (4) , 395-405
Development and Performance Optimization of a Multiplexed DOI-Encoding PET Detector Using the TOFPET2 ASIC
Depth-of-interaction (DOI) positron emission tomography (PET) detectors are essential in high-resolution small animal PET. The dual-ended readout detector configuration provides high DOI resolution; however, signal multiplexing schemes are often needed to reduce manufacturing costs. TOFPET2 is a low-cost, multi-channel application-specific integrated circuit (ASIC) designed for individual silicon photomultiplier (SiPM) readout, with performance in multiplexed configurations not well known. This study evaluates a highly multiplexed, high-resolution, dual-ended readout PET detector using TOFPET2. The PET detector was constructed with a 23 × 23 array of LYSO crystals (0.785 × 0.785 × 20 mm) coupled to 6 × 6 SiPM arrays (pitch = 3.3 mm) via 1.2 mm PMMA sheets. Custom boards reduced 72 SiPM signals to 8 (4 per end) before feeding into TOFPET2 channels. The detector was biased at 27, 27.5, and 28 V, with ASIC discriminator thresholds optimised based on flood map quality. Optimal flood maps were obtained at 27.5 V. The mean energy and DOI resolution were 10.5 ± 1.6% and 2.3 ± 0.3 mm, respectively, with a coincidence time resolution (CTR) of 1.3 ns between two detectors. This work demonstrates the feasibility of employing TOFPET2 to achieve high spatial, energy, and DOI resolution in a 9:1 multiplexed system.
- 22 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 9 (4) , 395-405
Open AccessDevelopment and Performance Optimization of a Multiplexed DOI-Encoding PET Detector Using the TOFPET2 ASIC
Depth-of-interaction (DOI) positron emission tomography (PET) detectors are essential in high-resolution small animal PET. The dual-ended readout detector configuration provides high DOI resolution; however, signal multiplexing schemes are often needed to reduce manufacturing costs. TOFPET2 is a low-cost, multi-channel application-specific integrated circuit (ASIC) designed for individual silicon photomultiplier (SiPM) readout, with performance in multiplexed configurations not well known. This study evaluates a highly multiplexed, high-resolution, dual-ended readout PET detector using TOFPET2. The PET detector was constructed with a 23 × 23 array of LYSO crystals (0.785 × 0.785 × 20 mm) coupled to 6 × 6 SiPM arrays (pitch = 3.3 mm) via 1.2 mm PMMA sheets. Custom boards reduced 72 SiPM signals to 8 (4 per end) before feeding into TOFPET2 channels. The detector was biased at 27, 27.5, and 28 V, with ASIC discriminator thresholds optimised based on flood map quality. Optimal flood maps were obtained at 27.5 V. The mean energy and DOI resolution were 10.5 ± 1.6% and 2.3 ± 0.3 mm, respectively, with a coincidence time resolution (CTR) of 1.3 ns between two detectors. This work demonstrates the feasibility of employing TOFPET2 to achieve high spatial, energy, and DOI resolution in a 9:1 multiplexed system.
- Open Access
- 28 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 29 (2) , 1165-1175
Head-Mounted Displays in Context-Aware Systems for Open Surgery: A State-of-the-Art Review
Surgical context-aware systems (SCAS), which leverage real-time data and analysis from the operating room to inform surgical activities, can be enhanced through the integration of head-mounted displays (HMDs). Rather than user-agnostic data derived from conventional, and often static, external sensors, HMD-based SCAS relies on dynamic user-centric sensing of the surgical context. The analyzed context-aware information is then augmented directly into a user's field of view via augmented reality (AR) to directly improve their task and decision-making capability. This stateof-the-art review complements previous reviews by exploring the advancement of HMD-based SCAS, including their development and impact on enhancing situational awareness and surgical outcomes in the operating room. The survey demonstrates that this technology can mitigate risks associated with gaps in surgical expertise, increase procedural efficiency, and improve patient outcomes. We also highlight key limitations still to be addressed by the research community, including improving prediction accuracy, robustly handling data heterogeneity, and reducing system latency.
- 28 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 29 (2) , 1165-1175
Open AccessHead-Mounted Displays in Context-Aware Systems for Open Surgery: A State-of-the-Art Review
Surgical context-aware systems (SCAS), which leverage real-time data and analysis from the operating room to inform surgical activities, can be enhanced through the integration of head-mounted displays (HMDs). Rather than user-agnostic data derived from conventional, and often static, external sensors, HMD-based SCAS relies on dynamic user-centric sensing of the surgical context. The analyzed context-aware information is then augmented directly into a user's field of view via augmented reality (AR) to directly improve their task and decision-making capability. This stateof-the-art review complements previous reviews by exploring the advancement of HMD-based SCAS, including their development and impact on enhancing situational awareness and surgical outcomes in the operating room. The survey demonstrates that this technology can mitigate risks associated with gaps in surgical expertise, increase procedural efficiency, and improve patient outcomes. We also highlight key limitations still to be addressed by the research community, including improving prediction accuracy, robustly handling data heterogeneity, and reducing system latency.
- Open Access
- 14 August 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (17) , 179501
Corrigendum: Virtual cylindrical PET for efficient DOI image reconstruction with sub-millimetre resolution (2024 Phys. Med. Biol. 69 115043)
- 14 August 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (17) , 179501
Open AccessCorrigendum: Virtual cylindrical PET for efficient DOI image reconstruction with sub-millimetre resolution (2024 Phys. Med. Biol. 69 115043)
- Open Access
- 5 August 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (16) , 165017
A deep neural network for positioning and inter-crystal scatter identification in multiplexed PET detectors: a simulation study
Objective. High-resolution positron emission tomography (PET) relies on the accurate positioning of annihilation photons impinging the crystal array. However, conventional positioning algorithms in light-sharing PET detectors are often limited due to edge effects and/or the absence of additional information for identifying and correcting scattering within the crystal array (known as inter-crystal scattering). This study explores the feasibility of deep neural network (DNN) techniques for more precise event positioning in finely segmented and highly multiplexed PET detectors with light-sharing. Approach. Initially, a Geant4 Application for Tomographic Emission (GATE) simulation was used to study the spatial and statistical properties of inter-crystal scatter (ICS) events in finely segmented LYSO PET detectors. Next, a DNN for crystal localisation was designed, trained and tested with light distributions of photoelectric (P) and Compton + photoelectric (CP) events simulated using optical GATE and an analytical method to speed up data generation. Using the statistical properties of ICS events, an energy-guided positioning algorithm was then built into the DNN. The positioning algorithm enables selection of the unique or first crystal of interaction in P and CP events, respectively. Performance of the DNN was compared with Anger logic using light distributions from simulated 511 keV point sources placed at different locations around a single PET detector module. Main results. The fraction of events forward and backward scattered in the LYSO detector was 0.54 and 0.46, respectively, whereas naïve application of the Klein–Nishina formulation predicts 70% forward scatter. Despite coarse photodetector data due to signal multiplexing, the DNN demonstrated a crystal classification accuracy of 90% for P events and 82% for CP events. For crystal positioning, the DNN outperformed Anger logic by at least 34% and 14% for P and CP events, respectively. Further improvement is somewhat constrained by the physics—specifically, the ratio of backward to forward scattering of gamma rays within the crystal array being close to 1. This prevents selecting the first crystal of interaction in CP events with a high degree of certainty. Significance. Light sharing and multiplexed PET detectors are common in high-resolution PET, yet their traditional positioning algorithms often underperform due to edge effects and/or the difficulty in correcting ICS events. Our study indicates that DNN-based event positioning has the potential to enhance 2D coincidence event positioning accuracy by nearly a factor of 3 compared to Anger logic. However, further improvements are difficult to foresee without additional information such as event timing.
- 5 August 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (16) , 165017
Open AccessA deep neural network for positioning and inter-crystal scatter identification in multiplexed PET detectors: a simulation study
Objective. High-resolution positron emission tomography (PET) relies on the accurate positioning of annihilation photons impinging the crystal array. However, conventional positioning algorithms in light-sharing PET detectors are often limited due to edge effects and/or the absence of additional information for identifying and correcting scattering within the crystal array (known as inter-crystal scattering). This study explores the feasibility of deep neural network (DNN) techniques for more precise event positioning in finely segmented and highly multiplexed PET detectors with light-sharing. Approach. Initially, a Geant4 Application for Tomographic Emission (GATE) simulation was used to study the spatial and statistical properties of inter-crystal scatter (ICS) events in finely segmented LYSO PET detectors. Next, a DNN for crystal localisation was designed, trained and tested with light distributions of photoelectric (P) and Compton + photoelectric (CP) events simulated using optical GATE and an analytical method to speed up data generation. Using the statistical properties of ICS events, an energy-guided positioning algorithm was then built into the DNN. The positioning algorithm enables selection of the unique or first crystal of interaction in P and CP events, respectively. Performance of the DNN was compared with Anger logic using light distributions from simulated 511 keV point sources placed at different locations around a single PET detector module. Main results. The fraction of events forward and backward scattered in the LYSO detector was 0.54 and 0.46, respectively, whereas naïve application of the Klein–Nishina formulation predicts 70% forward scatter. Despite coarse photodetector data due to signal multiplexing, the DNN demonstrated a crystal classification accuracy of 90% for P events and 82% for CP events. For crystal positioning, the DNN outperformed Anger logic by at least 34% and 14% for P and CP events, respectively. Further improvement is somewhat constrained by the physics—specifically, the ratio of backward to forward scattering of gamma rays within the crystal array being close to 1. This prevents selecting the first crystal of interaction in CP events with a high degree of certainty. Significance. Light sharing and multiplexed PET detectors are common in high-resolution PET, yet their traditional positioning algorithms often underperform due to edge effects and/or the difficulty in correcting ICS events. Our study indicates that DNN-based event positioning has the potential to enhance 2D coincidence event positioning accuracy by nearly a factor of 3 compared to Anger logic. However, further improvements are difficult to foresee without additional information such as event timing.
- Open Access
- 30 May 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (11) , 115043
Virtual cylindrical PET for efficient DOI image reconstruction with sub-millimetre resolution
Objective. Image reconstruction in high resolution, narrow bore PET scanners with depth of interaction (DOI) capability presents a substantial computational challenge due to the very high sampling in detector and image space. The aim of this study is to evaluate the use of a virtual cylinder in reducing the number of lines of response (LOR) for DOI-based reconstruction in high resolution PET systems while maintaining uniform sub-millimetre spatial resolution. Approach. Virtual geometry was investigated using the awake animal mousePET as a high resolution test case. Using GEANT4 Application for Tomographic Emission (GATE), we simulated the physical scanner and three virtual cylinder implementations with detector size 0.74 mm, 0.47 mm and 0.36 mm (vPET1, vPET2 and vPET3, respectively). The virtual cylinder condenses physical LORs stemming from various crystal pairs and DOI combinations, and which intersect a single virtual detector pair, into a single virtual LOR. Quantitative comparisons of the point spread function (PSF) at various positions within the field of view (FOV) were compared for reconstructions based on the vPET implementations and the physical scanner. We also assessed the impact of the anisotropic PSFs by reconstructing images of a micro Derenzo phantom. Main results. All virtual cylinder implementations achieved LOR data compression of at least 50% for DOI PET reconstruction. PSF anisotropy in radial and tangential profiles was chiefly influenced by DOI resolution and only marginally by virtual detector size. Spatial degradation introduced by virtual cylinders was most prominent in the axial profile. All virtual cylinders achieved sub-millimetre volumetric resolution across the FOV when 6-bin DOI reconstructions (3.3 mm DOI resolution) were performed. Using vPET2 with 6 DOI bins yielded nearly identical reconstructions to the non-virtual case in the transaxial plane, with an LOR compression factor of 86%. Resolution modelling significantly reduced the effects of the asymmetric PSF arising from the non-cylindrical geometry of mousePET. Significance. Narrow bore and high resolution PET scanners require detectors with DOI capability, leading to computationally demanding reconstructions due to the large number of LORs. In this study, we show that DOI PET reconstruction with 50%–86% LOR compression is possible using virtual cylinders while maintaining sub-millimetre spatial resolution throughout the FOV. The methodology and analysis can be extended to other scanners with DOI capability intended for high resolution PET imaging.
- 30 May 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (11) , 115043
Open AccessVirtual cylindrical PET for efficient DOI image reconstruction with sub-millimetre resolution
Objective. Image reconstruction in high resolution, narrow bore PET scanners with depth of interaction (DOI) capability presents a substantial computational challenge due to the very high sampling in detector and image space. The aim of this study is to evaluate the use of a virtual cylinder in reducing the number of lines of response (LOR) for DOI-based reconstruction in high resolution PET systems while maintaining uniform sub-millimetre spatial resolution. Approach. Virtual geometry was investigated using the awake animal mousePET as a high resolution test case. Using GEANT4 Application for Tomographic Emission (GATE), we simulated the physical scanner and three virtual cylinder implementations with detector size 0.74 mm, 0.47 mm and 0.36 mm (vPET1, vPET2 and vPET3, respectively). The virtual cylinder condenses physical LORs stemming from various crystal pairs and DOI combinations, and which intersect a single virtual detector pair, into a single virtual LOR. Quantitative comparisons of the point spread function (PSF) at various positions within the field of view (FOV) were compared for reconstructions based on the vPET implementations and the physical scanner. We also assessed the impact of the anisotropic PSFs by reconstructing images of a micro Derenzo phantom. Main results. All virtual cylinder implementations achieved LOR data compression of at least 50% for DOI PET reconstruction. PSF anisotropy in radial and tangential profiles was chiefly influenced by DOI resolution and only marginally by virtual detector size. Spatial degradation introduced by virtual cylinders was most prominent in the axial profile. All virtual cylinders achieved sub-millimetre volumetric resolution across the FOV when 6-bin DOI reconstructions (3.3 mm DOI resolution) were performed. Using vPET2 with 6 DOI bins yielded nearly identical reconstructions to the non-virtual case in the transaxial plane, with an LOR compression factor of 86%. Resolution modelling significantly reduced the effects of the asymmetric PSF arising from the non-cylindrical geometry of mousePET. Significance. Narrow bore and high resolution PET scanners require detectors with DOI capability, leading to computationally demanding reconstructions due to the large number of LORs. In this study, we show that DOI PET reconstruction with 50%–86% LOR compression is possible using virtual cylinders while maintaining sub-millimetre spatial resolution throughout the FOV. The methodology and analysis can be extended to other scanners with DOI capability intended for high resolution PET imaging.
- Open Access
Characterisation of the Intel RealSense D415 Stereo Depth Camera for Motion-Corrected CT Perfusion Imaging
Even for short protocols (<1 min), head movement can compromise accurate haemodynamic modelling of cerebral CT perfusion (CTP) imaging in acute stroke. Frame-to-frame registration is the most common form of retrospective correction but neglects the fact that motion is continuous, not discrete. By contrast, external tracking devices provide continuous motion monitoring and thereby the opportunity to fully correct the acquired data for motion. The aim of this study was to characterise the Intel D415 stereo depth camera, a compact low-cost markerless tracking device, in terms of its suitability for retrospective CTP motion correction. The results showed that jitter was stable, and thermally-induced pose drift was {\le} 1.5 mm and {\le} 0.5° during the first 10-20 min, after which it also became stable. For static poses, the mean difference between the Intel D415 motion estimates and ground-truth poses for a head phantom was {\le} 1.24 \pm 0.01 mm and {\le} 0.68 \pm 0.01° for position and orientation, respectively. For dynamic poses measured while a head phantom travelled smooth continuous trajectories with median speed 0.031 ms^(-1) (speed range 0-0.500 ms^(-1)), the root-mean-square-error (RMSE) was {\le} 1.40 \pm 0.12 mm and {\le} 0.24 \pm 0.02°. When tracking a simulated patient head trajectory derived from a clinical CTP scan, the average RMSE was {\le} 0.86 \pm 0.03 mm and {\le} 0.16 \pm 0.03°. Tracking the head motion of a human volunteer inside a clinical CT scanner, the average RMSE was {\le} 2.72 \pm 0.24 mm and {\le} 0.55 \pm 0.07°. Overall, our results suggest that a single D415 tracking system can achieve promising pose estimation accuracy, though still worse than typical brain CT resolution, including CTP. The error is likely to be reduced to a practical level by combining multiple devices and this should be investigated in future work.
Open AccessCharacterisation of the Intel RealSense D415 Stereo Depth Camera for Motion-Corrected CT Perfusion Imaging
Even for short protocols (<1 min), head movement can compromise accurate haemodynamic modelling of cerebral CT perfusion (CTP) imaging in acute stroke. Frame-to-frame registration is the most common form of retrospective correction but neglects the fact that motion is continuous, not discrete. By contrast, external tracking devices provide continuous motion monitoring and thereby the opportunity to fully correct the acquired data for motion. The aim of this study was to characterise the Intel D415 stereo depth camera, a compact low-cost markerless tracking device, in terms of its suitability for retrospective CTP motion correction. The results showed that jitter was stable, and thermally-induced pose drift was {\le} 1.5 mm and {\le} 0.5° during the first 10-20 min, after which it also became stable. For static poses, the mean difference between the Intel D415 motion estimates and ground-truth poses for a head phantom was {\le} 1.24 \pm 0.01 mm and {\le} 0.68 \pm 0.01° for position and orientation, respectively. For dynamic poses measured while a head phantom travelled smooth continuous trajectories with median speed 0.031 ms^(-1) (speed range 0-0.500 ms^(-1)), the root-mean-square-error (RMSE) was {\le} 1.40 \pm 0.12 mm and {\le} 0.24 \pm 0.02°. When tracking a simulated patient head trajectory derived from a clinical CTP scan, the average RMSE was {\le} 0.86 \pm 0.03 mm and {\le} 0.16 \pm 0.03°. Tracking the head motion of a human volunteer inside a clinical CT scanner, the average RMSE was {\le} 2.72 \pm 0.24 mm and {\le} 0.55 \pm 0.07°. Overall, our results suggest that a single D415 tracking system can achieve promising pose estimation accuracy, though still worse than typical brain CT resolution, including CTP. The error is likely to be reduced to a practical level by combining multiple devices and this should be investigated in future work.
- Open Access
- 31 July 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (16) , 165005
Reduction of scan duration and radiation dose in cerebral CT perfusion imaging of acute stroke using a recurrent neural network
Objective . Cerebral CT perfusion (CTP) imaging is most commonly used to diagnose acute ischaemic stroke and support treatment decisions. Shortening CTP scan duration is desirable to reduce the accumulated radiation dose and the risk of patient head movement. In this study, we present a novel application of a stochastic adversarial video prediction approach to reduce CTP imaging acquisition time. Approach . A variational autoencoder and generative adversarial network (VAE-GAN) were implemented in a recurrent framework in three scenarios: to predict the last 8 (24 s), 13 (31.5 s) and 18 (39 s) image frames of the CTP acquisition from the first 25 (36 s), 20 (28.5 s) and 15 (21 s) acquired frames, respectively. The model was trained using 65 stroke cases and tested on 10 unseen cases. Predicted frames were assessed against ground-truth in terms of image quality and haemodynamic maps, bolus shape characteristics and volumetric analysis of lesions. Main results . In all three prediction scenarios, the mean percentage error between the area, full-width-at-half-maximum and maximum enhancement of the predicted and ground-truth bolus curve was less than 4 ± 4%. The best peak signal-to-noise ratio and structural similarity of predicted haemodynamic maps was obtained for cerebral blood volume followed (in order) by cerebral blood flow, mean transit time and time to peak. For the 3 prediction scenarios, average volumetric error of the lesion was overestimated by 7%–15%, 11%–28% and 7%–22% for the infarct, penumbra and hypo-perfused regions, respectively, and the corresponding spatial agreement for these regions was 67%–76%, 76%–86% and 83%–92%. Significance . This study suggests that a recurrent VAE-GAN could potentially be used to predict a portion of CTP frames from truncated acquisitions, preserving the majority of clinical content in the images, and potentially reducing the scan duration and radiation dose simultaneously by 65% and 54.5%, respectively.
- 31 July 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (16) , 165005
Open AccessReduction of scan duration and radiation dose in cerebral CT perfusion imaging of acute stroke using a recurrent neural network
Objective . Cerebral CT perfusion (CTP) imaging is most commonly used to diagnose acute ischaemic stroke and support treatment decisions. Shortening CTP scan duration is desirable to reduce the accumulated radiation dose and the risk of patient head movement. In this study, we present a novel application of a stochastic adversarial video prediction approach to reduce CTP imaging acquisition time. Approach . A variational autoencoder and generative adversarial network (VAE-GAN) were implemented in a recurrent framework in three scenarios: to predict the last 8 (24 s), 13 (31.5 s) and 18 (39 s) image frames of the CTP acquisition from the first 25 (36 s), 20 (28.5 s) and 15 (21 s) acquired frames, respectively. The model was trained using 65 stroke cases and tested on 10 unseen cases. Predicted frames were assessed against ground-truth in terms of image quality and haemodynamic maps, bolus shape characteristics and volumetric analysis of lesions. Main results . In all three prediction scenarios, the mean percentage error between the area, full-width-at-half-maximum and maximum enhancement of the predicted and ground-truth bolus curve was less than 4 ± 4%. The best peak signal-to-noise ratio and structural similarity of predicted haemodynamic maps was obtained for cerebral blood volume followed (in order) by cerebral blood flow, mean transit time and time to peak. For the 3 prediction scenarios, average volumetric error of the lesion was overestimated by 7%–15%, 11%–28% and 7%–22% for the infarct, penumbra and hypo-perfused regions, respectively, and the corresponding spatial agreement for these regions was 67%–76%, 76%–86% and 83%–92%. Significance . This study suggests that a recurrent VAE-GAN could potentially be used to predict a portion of CTP frames from truncated acquisitions, preserving the majority of clinical content in the images, and potentially reducing the scan duration and radiation dose simultaneously by 65% and 54.5%, respectively.