Wearable Sensor Patch with Hydrogel Microneedles for In Situ Analysis of Interstitial Fluid
- 2 December 2023
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (49) , 56760-56773
Abstract
Continuous real-time monitoring of biomarkers in interstitial fluid is essential for tracking metabolic changes and facilitating the early detection and management of chronic diseases such as diabetes. However, developing minimally invasive sensors for the in situ analysis of interstitial fluid and addressing signal delays remain a challenge. Here, we introduce a wearable sensor patch incorporating hydrogel microneedles for rapid, minimally invasive collection of interstitial fluid from the skin while simultaneously measuring biomarker levels in situ. The sensor patch is stretchable to accommodate the swelling of the hydrogel microneedles upon extracting interstitial fluid and adapts to skin deformation during measurements, ensuring consistent sensing performance in detecting model biomarker concentrations, such as glucose and lactate, in a mouse model. The sensor patch exhibits in vitro sensitivities of 0.024 ± 0.002 μA mM-1 for glucose and 0.0030 ± 0.0004 μA mM-1 for lactate, with corresponding linear ranges of 0.1-3 and 0.1-12 mM, respectively. For in vivo glucose sensing, the sensor patch demonstrates a sensitivity of 0.020 ± 0.001 μA mM-1 and a detection range of 1-8 mM. By integrating a predictive model, the sensor patch can analyze and compensate for signal delays, improving calibration reliability and providing guidance for potential optimization in sensing performance. The sensor patch is expected to serve as a minimally invasive platform for the in situ analysis of multiple biomarkers in interstitial fluid, offering a promising solution for continuous health monitoring and disease management.Keywords
Funding Information
- Eli Lilly and Company (40003523)
- Purdue University
This publication has 60 references indexed in Scilit:
- Wearable non-invasive epidermal glucose sensors: A reviewTalanta, 2018
- The role of subcutaneous tissue stiffness on microneedle performance in a representative in vitro model of skinJournal of Controlled Release, 2017
- A Swellable Microneedle Patch to Rapidly Extract Skin Interstitial Fluid for Timely Metabolic AnalysisAdvanced Materials, 2017
- Polymeric microneedles based enzymatic electrodes for electrochemical biosensing of glucose and lactic acidSensors and Actuators B: Chemical, 2016
- Generalized Compact Modeling of Nanoparticle-Based Amperometric Glucose BiosensorsIEEE Transactions on Electron Devices, 2016
- Microneedle arrays as transdermal and intradermal drug delivery systems: Materials science, manufacture and commercial developmentMaterials Science and Engineering: R: Reports, 2016
- A continuous glucose monitoring device by graphene modified electrochemical sensor in microfluidic systemBiomicrofluidics, 2016
- A facile system to evaluate in vitro drug release from dissolving microneedle arraysInternational Journal of Pharmaceutics, 2016
- Effect of Force of Microneedle Insertion on the Permeability of Insulin in SkinJournal of Diabetes Science and Technology, 2014
- Sodium Bicarbonate Treatment during Transient or Sustained Lactic Acidemia in Normoxic and Normotensive RatsPLOS ONE, 2012