Marco Fratus
Research Subjects
Marco Fratus has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Muhammad Ashraful Alam
Elmore Family School of Electrical and Computer Engineering, Purdue University, West Lafayette, IN, USA
10 shared publications - Hyowon Lee
Weldon School of Biomedical Engineering, Purdue University, West Lafayette, USA
3 shared publications - James K. Nolan
Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana 47907, United States
3 shared publications Jongcheon Lim
3 shared publicationsChi Hwan Lee
2 shared publications- Emilee Madsen
Weldon School of Biomedical Engineering
2 shared publications
Latest Publications
- Open Access
- 22 December 2025
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 122 (52)
A closed-loop microneedle-integrated physiological model for predictive glycemic management
Continuous biomarker monitoring and on-demand therapy are essential for chronic disease management, with diabetes being a key example. Although continuous glucose monitoring (CGM) and insulin pumps are moving toward a closed-loop system, it remains difficult to predict how device design influences system performance. Traditional optimization methods are inefficient and empirical: Data-driven algorithms lack interpretability, trial-and-error design is time-consuming, and first-principle models are difficult to integrate at the system level. To address these challenges, we introduce a physics-based framework which integrates microneedle (MN) designs for sensing and therapy with a physiological model of glycemic control. The framework builds compact relationships showing how material, chemical, and geometrical features affect key metrics such as response time, extraction flux, and insulin delivery rate. Specifically, we develop a theory for three sensing MN types (hollow, porous/swellable, and nanostructured MNs) and one therapeutic patch (electro-termo-mechanical device) to create a predictive model for glycemic regulation. By linking device design to system behavior across time and spatial scales, we examine the framework in three cases: How disease progression, MN design, and MN sensitivity affect plasma glucose levels and time-in-range metrics. This work establishes the foundation for a physics-based digital twin for diabetes management, complementing ML, experiments, and numerical models. More broadly, it streamlines patch design, minimizing glycemic events and trial-and-error in next-generation CGM technology.
- 22 December 2025
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 122 (52)
Open AccessA closed-loop microneedle-integrated physiological model for predictive glycemic management
Continuous biomarker monitoring and on-demand therapy are essential for chronic disease management, with diabetes being a key example. Although continuous glucose monitoring (CGM) and insulin pumps are moving toward a closed-loop system, it remains difficult to predict how device design influences system performance. Traditional optimization methods are inefficient and empirical: Data-driven algorithms lack interpretability, trial-and-error design is time-consuming, and first-principle models are difficult to integrate at the system level. To address these challenges, we introduce a physics-based framework which integrates microneedle (MN) designs for sensing and therapy with a physiological model of glycemic control. The framework builds compact relationships showing how material, chemical, and geometrical features affect key metrics such as response time, extraction flux, and insulin delivery rate. Specifically, we develop a theory for three sensing MN types (hollow, porous/swellable, and nanostructured MNs) and one therapeutic patch (electro-termo-mechanical device) to create a predictive model for glycemic regulation. By linking device design to system behavior across time and spatial scales, we examine the framework in three cases: How disease progression, MN design, and MN sensitivity affect plasma glucose levels and time-in-range metrics. This work establishes the foundation for a physics-based digital twin for diabetes management, complementing ML, experiments, and numerical models. More broadly, it streamlines patch design, minimizing glycemic events and trial-and-error in next-generation CGM technology.
- 5 August 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
Mechanically Stable Fractal Microelectrode with Nanostructured Pt/PEDOT:PSS for a Reliable Neural Stimulation
Neural stimulation provides significant therapeutic benefits for patients with neurological disorders. PEDOT:PSS has gained attention as a neural electrode material, but its poor mechanical stability due to continuous cyclic charge injection, which is especially severe on ultrathin substrates, remains a big challenge for its clinical utility. To address this problem, we developed a mechanically and electrochemically stable PEDOT:PSS-based microelectrode for neural stimulation by utilizing enhanced adhesion on the vertical interface between the three-dimensional (3D) nanostructured substrate. Our microelectrode design incorporates a fractal geometry that increases the perimeter-to-area ratio, coupled with nanostructured platinum to enhance the surface area. The simple PEDOT:PSS-coated microelectrode exhibited outstanding mechanical stability, evidenced by various metrologies, such as scanning electron microscopy (SEM), energy-dispersive X-ray (EDX), and atomic force microscopy (AFM), which can facilitate wide industrial adoption. We further verified using numerical analysis that the fractal electrode with a nanostructured Pt/PEDOT:PSS coating outperforms the traditional PEDOT:PSS-coated circular electrode. This innovative combination of geometrical design and surface treatment introduces a novel approach to developing robust microelectrodes for reliable neural stimulation.
- 5 August 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
Mechanically Stable Fractal Microelectrode with Nanostructured Pt/PEDOT:PSS for a Reliable Neural Stimulation
Neural stimulation provides significant therapeutic benefits for patients with neurological disorders. PEDOT:PSS has gained attention as a neural electrode material, but its poor mechanical stability due to continuous cyclic charge injection, which is especially severe on ultrathin substrates, remains a big challenge for its clinical utility. To address this problem, we developed a mechanically and electrochemically stable PEDOT:PSS-based microelectrode for neural stimulation by utilizing enhanced adhesion on the vertical interface between the three-dimensional (3D) nanostructured substrate. Our microelectrode design incorporates a fractal geometry that increases the perimeter-to-area ratio, coupled with nanostructured platinum to enhance the surface area. The simple PEDOT:PSS-coated microelectrode exhibited outstanding mechanical stability, evidenced by various metrologies, such as scanning electron microscopy (SEM), energy-dispersive X-ray (EDX), and atomic force microscopy (AFM), which can facilitate wide industrial adoption. We further verified using numerical analysis that the fractal electrode with a nanostructured Pt/PEDOT:PSS coating outperforms the traditional PEDOT:PSS-coated circular electrode. This innovative combination of geometrical design and surface treatment introduces a novel approach to developing robust microelectrodes for reliable neural stimulation.
- Open Access
- 23 July 2025
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 122 (30)
Can we still use the Michaelis–Menten model for enzymatic microneedle sensors?
Since the 1960s, enzymatic sensors have been vital in healthcare and environmental monitoring due to their high selectivity. Traditionally, their performance is interpreted using the Michaelis–Menten (MM) equation, which assumes idealized, homogeneous, well-mixed laboratory conditions. However, integrating these sensors with microneedle (MN) patches for wearable applications introduces challenges such as spatial and temporal variations and limited reactant availability. Applying the MM model in such scenarios can lead to dramatic errors in enzyme kinetics and biomarker estimates, risking inaccurate substrate measurements and potentially life-threatening decisions. Here, we generalize the reaction–diffusion framework for enzymatic sensors and integrate it with analytical models for MN sensors. Our approach captures time-dependent MM variables, quantifies the rate of product formation, accounts for mass transport limitations, and provides expressions for response time and active substrate levels. This physics-based framework enables a) quantification of otherwise inaccessible parameters such as active substrate levels, b) accurate response-time predictions to reach steady-state conditions, c) improved data interpretation, and d) projection of enzymatic responses across various conditions. The study highlights the need for careful application of MM model in wearable microneedle sensors, where key assumptions may not hold. Our model can also extend to sensor degradation, inactivation, and hypoxia, making it broadly applicable to enzymatic sensors in diverse environments.
- 23 July 2025
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 122 (30)
Open AccessCan we still use the Michaelis–Menten model for enzymatic microneedle sensors?
Since the 1960s, enzymatic sensors have been vital in healthcare and environmental monitoring due to their high selectivity. Traditionally, their performance is interpreted using the Michaelis–Menten (MM) equation, which assumes idealized, homogeneous, well-mixed laboratory conditions. However, integrating these sensors with microneedle (MN) patches for wearable applications introduces challenges such as spatial and temporal variations and limited reactant availability. Applying the MM model in such scenarios can lead to dramatic errors in enzyme kinetics and biomarker estimates, risking inaccurate substrate measurements and potentially life-threatening decisions. Here, we generalize the reaction–diffusion framework for enzymatic sensors and integrate it with analytical models for MN sensors. Our approach captures time-dependent MM variables, quantifies the rate of product formation, accounts for mass transport limitations, and provides expressions for response time and active substrate levels. This physics-based framework enables a) quantification of otherwise inaccessible parameters such as active substrate levels, b) accurate response-time predictions to reach steady-state conditions, c) improved data interpretation, and d) projection of enzymatic responses across various conditions. The study highlights the need for careful application of MM model in wearable microneedle sensors, where key assumptions may not hold. Our model can also extend to sensor degradation, inactivation, and hypoxia, making it broadly applicable to enzymatic sensors in diverse environments.
- 24 October 2024
- Published by Elsevier in Electrochimica Acta
- Vol. 509
Impact of microelectrode geometry and surface finish on enzymatic biosensor performance
- 24 October 2024
- Published by Elsevier in Electrochimica Acta
- Vol. 509
Impact of microelectrode geometry and surface finish on enzymatic biosensor performance
- 21 October 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (17)
The viability of Parkinson's monitoring by microneedle patches: A theory-guided critical analysis
Diagnosis and treatment of Parkinson's disease (PD) are challenging because levodopa (LD)-dependent therapies primarily rely on symptom observation and management. More sophisticated methods for LD tracking, namely, high-performance liquid chromatography, UV, and mass spectrometry, etc., are expensive and slow. As a potential alternative, wearable microneedle (MN)-based patches, coated with nanodendrites (NDs), offer promising, continuous, and minimally invasive LD monitoring. Laboratory-based platforms show high sensitivity and sub-micrometer detection, but a predictive design framework does not exist. Here, we report an analytical framework I=f(LD) for ND-on-MNs, quantifying the amperometric response I of an ND-on-MN platform in terms of geometric, catalytic sensor parameters, and environmental conditions. We find the counter-intuitive results that the environmental factors (e.g., low medium diffusivity and LD fluctuation), rather than the details of sensor geometry, dictate the sensitivity limits. A scaled response against platform parameters provides key insights: (a) A maximum enhancement factor for this platform is around 12%, emphasizing the importance of optimizing sensor parameters; (b) Design strategies focusing on high-density sensing sites and efficient LD-ND binding offer the most effective solutions for improved detection; and (c) Increasing geometric dimensions is not recommended due to potential patient discomfort. The model, validated against experimental data, highlights the limitations of ND-on-MN technology for LD tracking and suggests directions for optimizing MN-based devices for PD management, including enhancing selectivity.
- 21 October 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (17)
The viability of Parkinson's monitoring by microneedle patches: A theory-guided critical analysis
Diagnosis and treatment of Parkinson's disease (PD) are challenging because levodopa (LD)-dependent therapies primarily rely on symptom observation and management. More sophisticated methods for LD tracking, namely, high-performance liquid chromatography, UV, and mass spectrometry, etc., are expensive and slow. As a potential alternative, wearable microneedle (MN)-based patches, coated with nanodendrites (NDs), offer promising, continuous, and minimally invasive LD monitoring. Laboratory-based platforms show high sensitivity and sub-micrometer detection, but a predictive design framework does not exist. Here, we report an analytical framework I=f(LD) for ND-on-MNs, quantifying the amperometric response I of an ND-on-MN platform in terms of geometric, catalytic sensor parameters, and environmental conditions. We find the counter-intuitive results that the environmental factors (e.g., low medium diffusivity and LD fluctuation), rather than the details of sensor geometry, dictate the sensitivity limits. A scaled response against platform parameters provides key insights: (a) A maximum enhancement factor for this platform is around 12%, emphasizing the importance of optimizing sensor parameters; (b) Design strategies focusing on high-density sensing sites and efficient LD-ND binding offer the most effective solutions for improved detection; and (c) Increasing geometric dimensions is not recommended due to potential patient discomfort. The model, validated against experimental data, highlights the limitations of ND-on-MN technology for LD tracking and suggests directions for optimizing MN-based devices for PD management, including enhancing selectivity.
- 28 March 2024
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 255, 116238
Theory of nanostructured sensors integrated in/on microneedles for diagnostics and therapy
- 28 March 2024
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 255, 116238
Theory of nanostructured sensors integrated in/on microneedles for diagnostics and therapy
- 14 December 2023
- Published by Springer Nature in Biomedical Microdevices
- Vol. 26 (1) , 1-12
Performance gain and electro-mechanical design optimization of microneedles for wearable sensor systems
Minimally invasive microneedle (MN) is an emerging technology platform for wearable and implantable diagnostics and therapeutics systems. These short MNs o
- 14 December 2023
- Published by Springer Nature in Biomedical Microdevices
- Vol. 26 (1) , 1-12
Performance gain and electro-mechanical design optimization of microneedles for wearable sensor systems
Minimally invasive microneedle (MN) is an emerging technology platform for wearable and implantable diagnostics and therapeutics systems. These short MNs o
- 2 December 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (49) , 56760-56773
Wearable Sensor Patch with Hydrogel Microneedles for In Situ Analysis of Interstitial Fluid
Continuous real-time monitoring of biomarkers in interstitial fluid is essential for tracking metabolic changes and facilitating the early detection and management of chronic diseases such as diabetes. However, developing minimally invasive sensors for the in situ analysis of interstitial fluid and addressing signal delays remain a challenge. Here, we introduce a wearable sensor patch incorporating hydrogel microneedles for rapid, minimally invasive collection of interstitial fluid from the skin while simultaneously measuring biomarker levels in situ. The sensor patch is stretchable to accommodate the swelling of the hydrogel microneedles upon extracting interstitial fluid and adapts to skin deformation during measurements, ensuring consistent sensing performance in detecting model biomarker concentrations, such as glucose and lactate, in a mouse model. The sensor patch exhibits in vitro sensitivities of 0.024 ± 0.002 μA mM-1 for glucose and 0.0030 ± 0.0004 μA mM-1 for lactate, with corresponding linear ranges of 0.1-3 and 0.1-12 mM, respectively. For in vivo glucose sensing, the sensor patch demonstrates a sensitivity of 0.020 ± 0.001 μA mM-1 and a detection range of 1-8 mM. By integrating a predictive model, the sensor patch can analyze and compensate for signal delays, improving calibration reliability and providing guidance for potential optimization in sensing performance. The sensor patch is expected to serve as a minimally invasive platform for the in situ analysis of multiple biomarkers in interstitial fluid, offering a promising solution for continuous health monitoring and disease management.
- 2 December 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (49) , 56760-56773
Wearable Sensor Patch with Hydrogel Microneedles for In Situ Analysis of Interstitial Fluid
Continuous real-time monitoring of biomarkers in interstitial fluid is essential for tracking metabolic changes and facilitating the early detection and management of chronic diseases such as diabetes. However, developing minimally invasive sensors for the in situ analysis of interstitial fluid and addressing signal delays remain a challenge. Here, we introduce a wearable sensor patch incorporating hydrogel microneedles for rapid, minimally invasive collection of interstitial fluid from the skin while simultaneously measuring biomarker levels in situ. The sensor patch is stretchable to accommodate the swelling of the hydrogel microneedles upon extracting interstitial fluid and adapts to skin deformation during measurements, ensuring consistent sensing performance in detecting model biomarker concentrations, such as glucose and lactate, in a mouse model. The sensor patch exhibits in vitro sensitivities of 0.024 ± 0.002 μA mM-1 for glucose and 0.0030 ± 0.0004 μA mM-1 for lactate, with corresponding linear ranges of 0.1-3 and 0.1-12 mM, respectively. For in vivo glucose sensing, the sensor patch demonstrates a sensitivity of 0.020 ± 0.001 μA mM-1 and a detection range of 1-8 mM. By integrating a predictive model, the sensor patch can analyze and compensate for signal delays, improving calibration reliability and providing guidance for potential optimization in sensing performance. The sensor patch is expected to serve as a minimally invasive platform for the in situ analysis of multiple biomarkers in interstitial fluid, offering a promising solution for continuous health monitoring and disease management.
- Open Access
- 26 September 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 48 (1) , 29
The Emergence of Microneedle-Based Smart Sensor/Drug-Delivery Patches: A Scaling Theory Defines the Tradeoff between the Response Time and the Limits of Detection
Smart, ultra-scaled, always-on wearable, and implantable (WI) sensors are an exciting frontier in personalized medicine. These sensors integrate sensing and actuation capabilities, enabling real-time analyte detection for on-demand drug delivery, akin to a biological organ. The microneedle (MN)-based patch serves as a critical novel interface element in this system. It is inexpensive, minimally invasive, and safe, showing promise in glycemic management and insulin therapy in laboratory and animal studies. However, the current design of MNs relies primarily on empirical approaches, with significant challenges. These challenges include potential diffusion delays that may impede time-critical drug intervention and an iterative design process lacking a clear understanding of the tradeoff between the response time and the limits of detection. In this paper, we introduce the first predictive framework for MN sensors, based on physical scaling laws and biomimetic concepts. Our framework is supported by experimental and numerical validations, establishing analytical scaling relationships that capture the fundamental workings of hollow and porous-swellable MN sensors. It quantifies essential performance metrics like the ’response time (RT)’ and the ’limit of detection (LOD)’ while assessing the tradeoffs associated with various geometrical and physical parameters of the MN technology. As a result, our model provides a universal framework for interpreting/integrating the experimental findings reported by laboratories worldwide. By leveraging this predictive framework, researchers can advance the development and optimization of MN sensors, leading to improved performance and expanded applications in the field of wearable and implantable technologies.
- 26 September 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 48 (1) , 29
Open AccessThe Emergence of Microneedle-Based Smart Sensor/Drug-Delivery Patches: A Scaling Theory Defines the Tradeoff between the Response Time and the Limits of Detection
Smart, ultra-scaled, always-on wearable, and implantable (WI) sensors are an exciting frontier in personalized medicine. These sensors integrate sensing and actuation capabilities, enabling real-time analyte detection for on-demand drug delivery, akin to a biological organ. The microneedle (MN)-based patch serves as a critical novel interface element in this system. It is inexpensive, minimally invasive, and safe, showing promise in glycemic management and insulin therapy in laboratory and animal studies. However, the current design of MNs relies primarily on empirical approaches, with significant challenges. These challenges include potential diffusion delays that may impede time-critical drug intervention and an iterative design process lacking a clear understanding of the tradeoff between the response time and the limits of detection. In this paper, we introduce the first predictive framework for MN sensors, based on physical scaling laws and biomimetic concepts. Our framework is supported by experimental and numerical validations, establishing analytical scaling relationships that capture the fundamental workings of hollow and porous-swellable MN sensors. It quantifies essential performance metrics like the ’response time (RT)’ and the ’limit of detection (LOD)’ while assessing the tradeoffs associated with various geometrical and physical parameters of the MN technology. As a result, our model provides a universal framework for interpreting/integrating the experimental findings reported by laboratories worldwide. By leveraging this predictive framework, researchers can advance the development and optimization of MN sensors, leading to improved performance and expanded applications in the field of wearable and implantable technologies.
- 22 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (13) , 14285-14294
Geometry-Defined Response Time and Sensitivity for Microneedle-Based Amperometric Sensors
Smart, ultra-scaled, always-on wearable (and implantable) sensors are an exciting frontier of modern medicine. Among them, minimally invasive microneedles (MN) is an emerging technology platform for theragnostic applications. Compared to traditional continuous glucose measurement (CGM) devices, these MNs offer pain-less insertion and simple operation. These MN systems, however, rely on analyte diffusion from the interstitial fluid (ISF) to the sensing site, and thus, (a) introduce a substantial and intrinsic diffusion delay in sensor response, and (b) reduce the analyte concentration to which the sensor must respond. A diversity of experimental platforms has been proposed to improve performance, but their optimization relies on empirical iterative approaches. Here, we integrate the theory of transient flux balance and the biomimetic concepts from ion uptake by bacteria to derive a generalized physics-guided model for MN sensors. The framework suggests strategies to minimize response time and maximize extracted analyte concentration in terms of the geometric and physical properties of the system. Our results show that there exists an intrinsic trade-off between response time and extracted analyte concentration. Our model, validated against numerical simulations and experiment data, offers a predictive design framework that would significantly reduce the optimization time for MN-based sensor platforms.
- 22 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (13) , 14285-14294
Geometry-Defined Response Time and Sensitivity for Microneedle-Based Amperometric Sensors
Smart, ultra-scaled, always-on wearable (and implantable) sensors are an exciting frontier of modern medicine. Among them, minimally invasive microneedles (MN) is an emerging technology platform for theragnostic applications. Compared to traditional continuous glucose measurement (CGM) devices, these MNs offer pain-less insertion and simple operation. These MN systems, however, rely on analyte diffusion from the interstitial fluid (ISF) to the sensing site, and thus, (a) introduce a substantial and intrinsic diffusion delay in sensor response, and (b) reduce the analyte concentration to which the sensor must respond. A diversity of experimental platforms has been proposed to improve performance, but their optimization relies on empirical iterative approaches. Here, we integrate the theory of transient flux balance and the biomimetic concepts from ion uptake by bacteria to derive a generalized physics-guided model for MN sensors. The framework suggests strategies to minimize response time and maximize extracted analyte concentration in terms of the geometric and physical properties of the system. Our results show that there exists an intrinsic trade-off between response time and extracted analyte concentration. Our model, validated against numerical simulations and experiment data, offers a predictive design framework that would significantly reduce the optimization time for MN-based sensor platforms.