A Study of the 16-Segment Regional Wall Motion Scoring Index and Biplane Simpson's Rule for the Calculation of Left Ventricular Ejection Fraction: A Comparison with Cardiac Magnetic Resonance Imaging
- 1 July 2011
- journal article
- research article
- Published by Wiley in Echocardiography
- Vol. 28 (6) , 597-604
Abstract
Accurate calculation of left ventricular ejection fraction (LVEF) is important for diagnostic, prognostic and therapeutic reasons. Cardiac magnetic resonance (CMR) is the reference standard for LVEF calculation, followed by real time three-dimensional echocardiography (RT3DE). Limited availability of CMR and RT3DE leaves Simpson's rule as the two-dimensional echocardiography (2DE) standard by which LVEF is calculated. We investigated the accuracy of the 16-Segment Regional Wall Motion Score Index (RWMSI) as an alternative method for calculating LVEF by 2DE and compared this to Simpson's rule and CMR. The 2D echocardiograms of 110 patients were studied (LVEF range: 7-74%); 57 of these underwent CMR. A RWMS was applied, based on the consensus opinion of two experienced cardiologists, to each of 16 American Heart Association myocardial segments (RWMSI: hyperkinesis = 3; normal regional contraction = 2; mild hypokinesis = 1.25; severe hypokinesis = 0.75; akinesis = 0; dyskinesis =-1). LVEF was calculated by: LVEF(%) =Σ(16segRWMS)/16×30. LVEF was calculated by Simpson's rule and CMR using standard methods. Results were correlated against CMR. Intertechnique agreement was examined. A P value of<0.05 was considered significant. RWMSI-LVEF correlated strongly with Biplane Simpson's rule (P< 0.001, r = 0.915). RWMSI-LVEF had a strong correlation to CMR (P < 0.001, r = 0.916); Simpson's rule-LVEF had a moderate correlation to CMR (P< 0.001, r = 0.647). In patients with LV dysfunction (EF < 55%), on linear regression analysis, RWMSI-LVEF had a better correlation with CMR than Simpson's rule. Further more Simpson's rule overestimated LVEF compared to CMR (mean difference: -6.12 ± 16.44, P = 0.002) whereas RWMSI did not (mean difference: 2.58 ± 14.80, P = NS). RWMSI-LVEF correlates strongly with CMR with good intertechnique agreement. In centers where CMR and RT3DE are not readily available, the use by experienced individuals, of the RWMSI for calculating LVEF may be a more simple, accurate, and reliable alternative to Simpson's rule.Keywords
This publication has 11 references indexed in Scilit:
- Cardiac magnetic resonance versus transthoracic echocardiography for the assessment of cardiac volumes and regional function after myocardial infarction: an intrasubject comparison using simultaneous intrasubject recordingsCardiovascular Ultrasound, 2009
- Cardiac MRI Assessment of Left and Right Ventricular Parameters in Healthy Australian Normal VolunteersHeart, Lung and Circulation, 2008
- Recommendations for Chamber Quantification: A Report from the American Society of Echocardiography’s Guidelines and Standards Committee and the Chamber Quantification Writing Group, Developed in Conjunction with the European Association of Echocardiography, a Branch of the European Society of CardiologyJournal of the American Society of Echocardiography, 2005
- Rapid full volume data acquisition by real-time 3-dimensional echocardiography for assessment of left ventricular indexes in children: A validation study compared with magnetic resonance imagingJournal of the American Society of Echocardiography, 2005
- Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-time three-dimensional echocardiographyJACC, 2004
- ACC/AHA/ASE 2003 guideline update for the clinical application of echocardiography: summary articleJACC, 2003
- ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices—Summary ArticleJACC, 2002
- Contrast echocardiography improves the accuracy and reproducibility of left ventricular remodeling measurementsJACC, 2001
- Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance. Are they interchangeable?European Heart Journal, 2000
- Importance of imaging method over imaging modality in noninvasive determination of left ventricular volumes and ejection fractionJACC, 2000