Smartphone-Based Quantitative Measurement of Capillary Refill Time
Open Access
- 3 March 2026
- journal article
- research article
- Published by MDPI AG in Instruments
- Vol. 10 (1) , 15
Abstract
Capillary refill time (CRT) is widely used in pediatric and emergency medicine as an indicator of peripheral circulation. CRT is defined as the time required for the skin to return to its original color after external compression is applied and then released. In current clinical practice, however, CRT assessment remains qualitative and relies heavily on the magnitude and consistency of compression applied by the measurer, as well as on subjective visual color perception, which together result in limited measurement reliability. To improve measurement reliability, several quantitative CRT measurement devices have been developed. Nevertheless, these devices are dedicated specifically to CRT measurement, which limits their versatility and complicates clinical implementation. In this study, we developed a simple and quantitative CRT measurement method using a smartphone. Based on skin color changes captured by the rear camera, we proposed a method to assess the adequacy of the applied compression force and implemented an application to calculate CRT. In addition, we investigated an algorithm to reduce the influence of pulse waves observed in the post-release waveform, enabling more stable CRT estimation. Furthermore, a dedicated smartphone case was designed to immobilize the finger during measurement, thereby improving measurement reliability. The feasibility of the proposed method was evaluated by examining agreement with a previously developed CRT measurement device and by assessing intraexaminer reliability, confirming its effectiveness.Keywords
This publication has 15 references indexed in Scilit:
- DiCARTTM device to measure capillary refill time: a validation study in patients with acute circulatory failureJournal of Clinical Monitoring and Computing, 2025
- The Effect of Repeated Capillary Refill Tests on the Cutaneous MicrocirculationJournal of Biophotonics, 2024
- Pilot study on optimizing pressure for standardized capillary refill time measurementHeliyon, 2024
- Feasibility study of wearable capillary refill time measurement deviceArtificial Life and Robotics, 2024
- The association between prolonged capillary refill time and microcirculation changes in children with sepsisBMC Pediatrics, 2024
- Portable measurement device to quantitatively measure capillary refilling timeArtificial Life and Robotics, 2022
- The standardized method and clinical experience may improve the reliability of visually assessed capillary refill timeThe American Journal of Emergency Medicine, 2021
- Cuff-Less Blood Pressure Monitoring System Using SmartphonesIEEE Access, 2020
- Low temperature increases capillary blood refill time following mechanical fingertip compression of healthy volunteers: prospective cohort studyJournal of Clinical Monitoring and Computing, 2018
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986