Chiho Miyazawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Chiho Miyazawa has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Masayoshi Shinozaki
Department of Medical Engineering, Graduate School of Science and Engineering, Chiba University, Chiba, Japan
1 shared publication - Satoshi Karasawa
Department of Emergency and Critical Care Medicine, Chiba University Graduate School of Medicine, Chiba 260-8677, Japan
1 shared publication - Taka-Aki Nakada
Department of Emergency and Critical Care Medicine, Chiba University Graduate School of Medicine, Chiba, Japan
1 shared publication - Toshiya Nakaguchi
Center of Frontier Medical Engineering, Chiba University, Chiba 263-8522, Japan
1 shared publication - Yayoi Miwa
Department of Emergency and Critical Care Medicine, Chiba University Graduate School of Medicine, Chiba 260-8677, Japan
1 shared publication - Yukihiro Nomura
Center for Frontier Medical Engineering, Chiba University, Chiba, Japan
1 shared publication
Latest Publications
- Open Access
- 3 March 2026
- Published by MDPI AG in Instruments
- Vol. 10 (1) , 15
Smartphone-Based Quantitative Measurement of Capillary Refill Time
Capillary refill time (CRT) is widely used in pediatric and emergency medicine as an indicator of peripheral circulation. CRT is defined as the time required for the skin to return to its original color after external compression is applied and then released. In current clinical practice, however, CRT assessment remains qualitative and relies heavily on the magnitude and consistency of compression applied by the measurer, as well as on subjective visual color perception, which together result in limited measurement reliability. To improve measurement reliability, several quantitative CRT measurement devices have been developed. Nevertheless, these devices are dedicated specifically to CRT measurement, which limits their versatility and complicates clinical implementation. In this study, we developed a simple and quantitative CRT measurement method using a smartphone. Based on skin color changes captured by the rear camera, we proposed a method to assess the adequacy of the applied compression force and implemented an application to calculate CRT. In addition, we investigated an algorithm to reduce the influence of pulse waves observed in the post-release waveform, enabling more stable CRT estimation. Furthermore, a dedicated smartphone case was designed to immobilize the finger during measurement, thereby improving measurement reliability. The feasibility of the proposed method was evaluated by examining agreement with a previously developed CRT measurement device and by assessing intraexaminer reliability, confirming its effectiveness.
- 3 March 2026
- Published by MDPI AG in Instruments
- Vol. 10 (1) , 15
Open AccessSmartphone-Based Quantitative Measurement of Capillary Refill Time
Capillary refill time (CRT) is widely used in pediatric and emergency medicine as an indicator of peripheral circulation. CRT is defined as the time required for the skin to return to its original color after external compression is applied and then released. In current clinical practice, however, CRT assessment remains qualitative and relies heavily on the magnitude and consistency of compression applied by the measurer, as well as on subjective visual color perception, which together result in limited measurement reliability. To improve measurement reliability, several quantitative CRT measurement devices have been developed. Nevertheless, these devices are dedicated specifically to CRT measurement, which limits their versatility and complicates clinical implementation. In this study, we developed a simple and quantitative CRT measurement method using a smartphone. Based on skin color changes captured by the rear camera, we proposed a method to assess the adequacy of the applied compression force and implemented an application to calculate CRT. In addition, we investigated an algorithm to reduce the influence of pulse waves observed in the post-release waveform, enabling more stable CRT estimation. Furthermore, a dedicated smartphone case was designed to immobilize the finger during measurement, thereby improving measurement reliability. The feasibility of the proposed method was evaluated by examining agreement with a previously developed CRT measurement device and by assessing intraexaminer reliability, confirming its effectiveness.