pH Quantification in Human Dermal Interstitial Fluid Using Ultra-Thin SOI Silicon Nanowire ISFETs and a High-Sensitivity Constant-Current Approach
Open Access
- 27 September 2023
- journal article
- research article
- Published by MDPI AG in Biosensors
- Vol. 13 (10) , 908
Abstract
In this paper, we propose a novel approach to utilize silicon nanowires as high-sensitivity pH sensors. Our approach works based on fixing the current bias of silicon nanowires Ion Sensitive Field Effect Transistors (ISFETs) and monitor the resulting drain voltage as the sensing signal. By fine tuning the injected current levels, we can optimize the sensing conditions according to different sensor requirements. This method proves to be highly suitable for real-time and continuous measurements of biomarkers in human biofluids. To validate our approach, we conducted experiments, with real human sera samples to simulate the composition of human interstitial fluid (ISF), using both the conventional top-gate approach and the optimized constant current method. We successfully demonstrated pH sensing within the physiopathological range of 6.5 to 8, achieving an exceptional level of accuracy in this complex matrix. Specifically, we obtained a maximum error as low as 0.92% (equivalent to 0.07 pH unit) using the constant-current method at the optimal current levels (1.71% for top-gate). Moreover, by utilizing different pools of human sera with varying total protein content, we demonstrated that the protein content among patients does not impact the sensors’ performance in pH sensing. Furthermore, we tested real-human ISF samples collected from volunteers. The obtained accuracy in this scenario was also outstanding, with an error as low as 0.015 pH unit using the constant-current method and 0.178 pH unit in traditional top-gate configuration.Keywords
All Related Versions
Funding Information
- European Union’s Horizon 2020 Research and Innovation Programme (101017915)
This publication has 23 references indexed in Scilit:
- Roles of interstitial fluid pH in diabetes mellitus: Glycolysis and mitochondrial functionWorld Journal of Diabetes, 2015
- Treatment of acute metabolic acidosis: a pathophysiologic approachNature Reviews Nephrology, 2012
- An Integrated ISFET Sensor ArraySensors, 2009
- Nanowire sensors for multiplexed detection of biomoleculesCurrent Opinion in Chemical Biology, 2008
- Metabolic acidosis in the intensive care unitCritical Care Clinics, 2002
- Interstitial pH in human skeletal muscle during and after dynamic graded exerciseThe Journal of Physiology, 2001
- Interstitial pH in human skeletal muscle during and after dynamic graded exerciseThe Journal of Physiology, 2001
- Measurement of interstitial albumin in human skeletal muscle and adipose tissue by open-flow microperfusionAmerican Journal of Physiology-Endocrinology and Metabolism, 2000
- Protein Concentration in Interstitial and Lymphatic Fluids from the Subcutaneous TissueActa Physiologica Scandinavica, 1977
- Comparative analysis of the protein content of local subcutaneous tissue fluid and plasmaMicrovascular Research, 1970