Physical analysis of the shielding capacity for a lightweight apron designed for shielding low intensity scattering X-rays
Open Access
- 27 July 2016
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 6 (1) , 27721
Abstract
The purpose of this paper is to develop a lightweight apron that will be used for shielding low intensity radiation in medical imaging radiography room and to apply it to a custom-made effective shielding. The quality of existing aprons made for protecting our bodies from direct radiation are improved so that they are suitable for scattered X-rays. Textiles that prevent bodies from radiation are made by combining barium sulfate and liquid silicon. These materials have the function of shielding radiation in a manner like lead. Three kinds of textiles are produced. The thicknesses of each textile are 0.15 mm, 0.21 mm, and 0.29 mm and the corresponding lead equivalents are 0.039 mmPb, 0.095 mmPb, 0.22 mmPb for each. The rate of shielding space scattering rays are 80% from the distance of 0.5 m, 86% from 1.0 m, and 97% from 1.5 m. If we intend to approach with the purpose of shielding scattering X-rays and low intensity radiations, it is possible to reduce the weight of the apron to be 1/5 compared to that of the existing lead aprons whose weight is typically more than 4 kg. We confirm, therefore, that it is possible to produce lightweight aprons that are used for the purpose of shielding low dose radiations.Keywords
This publication has 13 references indexed in Scilit:
- Doses to operators during interventional radiology procedures: focus on eye lens and extremity dosimetryRadiation Protection Dosimetry, 2010
- Occupational Radiation Protection in Interventional Radiology: A Joint Guideline of the Cardiovascular and Interventional Radiology Society of Europe and the Society of Interventional RadiologyJournal of Vascular and Interventional Radiology, 2010
- Usefulness of non-lead aprons in radiation protection for physicians performing interventional proceduresRadiation Protection Dosimetry, 2008
- A comparison of dose savings of lead and lightweight aprons for shielding of 99m-Technetium radiationRadiation Protection Dosimetry, 2007
- Evaluation of a radiation protection cabin for invasive electrophysiological proceduresEuropean Heart Journal, 2006
- Radiation risks for the radiologist performing transjugular intrahepatic portosystemic shunt (TIPS)British Journal of Radiology, 2006
- Impact of a lead glass screen on scatter radiation to eyes and hands in interventional cardiologistsCatheterization and Cardiovascular Interventions, 2005
- Standardization of Occupational Dose to Patient DAP Enables Reliable Assessment of Radiation-Protection Devices in Invasive CardiologyRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2003
- The dependence of the scattered radiation dose to personnel on technique factors in diagnostic radiologyBritish Journal of Radiology, 1992
- Photon mass attenuation and energy-absorption coefficientsThe International Journal of Applied Radiation and Isotopes, 1982