Brief Communication Simple Mathematical and Computational Wear Model for Ultra-High-Molecular-Weight Polyethylene Total Hip Replacements
Open Access
- 1 January 2007
- journal article
- research article
- Published by Hindawi Limited in Applied Bionics and Biomechanics
- Vol. 4 (2) , 83-88
Abstract
Ultra-high-molecular-weight polyethylene is an important constituent of hip implants. Surgical revisions are required because of implant loosening and osteolysis (destruction or resorption of bone tissue). We develop a mathematical and a computational model to determine implant life (defined as the time when 20% of the implants operating at a given wear rate is revised) based on wear rates and apply them to the data of Sochart (Clin Orthop Relat Res, 363:135–50, 1999). No significant difference was found between mathematical and computational model predictions (14.8 and 14.7 years, respectively) from the actual value of 15.0 ± 3.9 years (± 2SE; P > 0.05). We find that an increase in cross-linking does not decrease implant life greatly. However, a large decrease in implant life occurs with an increase in surface roughness, cycles per year and body weight or a decrease in contact stress and femoral head radius.
Keywords
This publication has 20 references indexed in Scilit:
- The relative influence of five variables on the in vitro wear rate of uncrosslinked UHMWPE acetabular cup linersBiomaterials, 2003
- A unified theory of wear for ultra-high molecular weight polyethylene in multi-directional slidingWear, 2001
- Effect of contact stress on friction and wear of ultra-high molecular weight polyethylene in total hip replacementProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2001
- A frictional study of total hip joint replacementsPhysics in Medicine & Biology, 2000
- Relationship of Acetabular Wear to Osteolysis and Loosening in Total Hip ArthroplastyClinical Orthopaedics and Related Research, 1999
- Is staircase walking a risk for the fixation of hip implants?Journal of Biomechanics, 1995
- Wear mechanisms of UHMWPE in total joint replacementsWear, 1995
- Hip joint loading during walking and running, measured in two patientsJournal of Biomechanics, 1993
- Survivorship analysis of total hip replacements. Results in a series of active patients who were less than fifty-five years old.Journal of Bone and Joint Surgery, 1986
- Reactions of the articular capsule to wear products of artificial joint prosthesesJournal of Biomedical Materials Research, 1977