K. H. S. Chan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
K. H. S. Chan has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
J. Li
Department of Zoology, University of British Columbia, Vancouver, British Columbia, V6T 1Z4, Canada
2 shared publicationsF. Wong
Department of Zoology, University of British Columbia, Vancouver, British Columbia, Canada V6T 1Z4
1 shared publicationL. Chow
Department of Zoology, University of British Columbia, Vancouver, British Columbia, Canada V6T 1Z4
1 shared publicationP. Y. L. Kwok
Department of Zoology, University of British Columbia, Vancouver, British Columbia, V6T 1Z4, Canada
1 shared publicationR. W. Blake
Department of Zoology, University of British Columbia, Vancouver, British Columbia, V6T 1Z4, Canada
1 shared publication- Robert W. Blake
Department of Zoology, University of British Columbia, British Columbia, V6T 1Z4 Canada
1 shared publication
Latest Publications
- 9 October 2007
- Published by Wiley in Journal of Fish Biology
- Vol. 71 (4) , 1203-1207
Evaluation using multilayer perception neural networks: a case study of undulatory median fin swimming in the knifefish Xenomystus nigri
In this study, artificial intelligence, namely multilayer perception neural networks (MLP‐NN), was employed to predict the hydrodynamic performance of undulatory median fin propulsion in Xenomystus nigri. Good agreement was found between MLP‐NN predictions and actual mean thrust and power values calculated from elongated‐body theory. MLP‐NN has the ability to be a predictive tool for autonomous underwater vehicle design and hydrodynamic performance.
- 9 October 2007
- Published by Wiley in Journal of Fish Biology
- Vol. 71 (4) , 1203-1207
Evaluation using multilayer perception neural networks: a case study of undulatory median fin swimming in the knifefish Xenomystus nigri
In this study, artificial intelligence, namely multilayer perception neural networks (MLP‐NN), was employed to predict the hydrodynamic performance of undulatory median fin propulsion in Xenomystus nigri. Good agreement was found between MLP‐NN predictions and actual mean thrust and power values calculated from elongated‐body theory. MLP‐NN has the ability to be a predictive tool for autonomous underwater vehicle design and hydrodynamic performance.
- Open Access
- 1 January 2007
- Published by Hindawi Limited in Applied Bionics and Biomechanics
- Vol. 4 (2) , 83-88
Brief Communication Simple Mathematical and Computational Wear Model for Ultra-High-Molecular-Weight Polyethylene Total Hip Replacements
Ultra-high-molecular-weight polyethylene is an important constituent of hip implants. Surgical revisions are required because of implant loosening and osteolysis (destruction or resorption of bone tissue). We develop a mathematical and a computational model to determine implant life (defined as the time when 20% of the implants operating at a given wear rate is revised) based on wear rates and apply them to the data of Sochart (Clin Orthop Relat Res, 363:135–50, 1999). No significant difference was found between mathematical and computational model predictions (14.8 and 14.7 years, respectively) from the actual value of 15.0 ± 3.9 years (± 2SE; P > 0.05). We find that an increase in cross-linking does not decrease implant life greatly. However, a large decrease in implant life occurs with an increase in surface roughness, cycles per year and body weight or a decrease in contact stress and femoral head radius.- 1 January 2007
- Published by Hindawi Limited in Applied Bionics and Biomechanics
- Vol. 4 (2) , 83-88
Open AccessBrief Communication Simple Mathematical and Computational Wear Model for Ultra-High-Molecular-Weight Polyethylene Total Hip Replacements
Ultra-high-molecular-weight polyethylene is an important constituent of hip implants. Surgical revisions are required because of implant loosening and osteolysis (destruction or resorption of bone tissue). We develop a mathematical and a computational model to determine implant life (defined as the time when 20% of the implants operating at a given wear rate is revised) based on wear rates and apply them to the data of Sochart (Clin Orthop Relat Res, 363:135–50, 1999). No significant difference was found between mathematical and computational model predictions (14.8 and 14.7 years, respectively) from the actual value of 15.0 ± 3.9 years (± 2SE; P > 0.05). We find that an increase in cross-linking does not decrease implant life greatly. However, a large decrease in implant life occurs with an increase in surface roughness, cycles per year and body weight or a decrease in contact stress and femoral head radius.