Imaging Pulmonary Blood Flow Using Pseudocontinuous Arterial Spin Labeling (PCASL) With Balanced Steady‐State Free‐Precession (bSSFP) Readout at 1.5T
Open Access
- 5 July 2020
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 52 (6) , 1767-1782
Abstract
Background: Quantitative assessment of pulmonary blood flow and visualization of its temporal and spatial distribution without contrast media is of clinical significance.Purpose: To assess the potential of electrocardiogram (ECG)‐triggered pseudocontinuous arterial spin labeling (PCASL) imaging with balanced steady‐state free‐precession (bSSFP) readout to measure lung perfusion under free‐breathing (FB) conditions and to study temporal and spatial characteristics of pulmonary blood flow.Study Type: Prospective, observational.Subjects: Fourteen volunteers; three patients with pulmonary embolism.Field Strength/Sequences: 1.5T, PCASL‐bSSFP.Assessment: The pulmonary trunk was labeled during systole. The following examinations were performed: 1) FB and timed breath‐hold (TBH) examinations with a postlabeling delay (PLD) of 1000 msec, and 2) TBH examinations with multiple PLDs (100–1500 msec). Scan–rescan measurements were performed in four volunteers and one patient. Images were registered and the perfusion was evaluated in large vessels, small vessels, and parenchyma. Mean structural similarity indices (MSSIM) was computed and time‐to‐peak (TTP) of parenchymal perfusion in multiple PLDs was evaluated. Image quality reading was performed with three independent blinded readers.Statistical Tests: Wilcoxon test to compare MSSIM, perfusion, and Likert scores. Spearman's correlation to correlate TTP and cardiac cycle duration. The repeatability coefficient (RC) and within‐subject coefficient of variation (wCV) for scan–rescan measurements. Intraclass correlation coefficient (ICC) for interreader agreement.Results: Image registration resulted in a significant (P < 0.05) increase of MSSIM. FB perfusion values were 6% higher than TBH (3.28 ± 1.09 vs. 3.10 ± 0.99 mL/min/mL). TTP was highly correlated with individuals' cardiac cycle duration (Spearman = 0.89, P < 0.001). RC and wCV were better for TBH than FB (0.13–0.19 vs. 0.47–1.54 mL/min/mL; 6–7 vs. 19–60%). Image quality was rated very good, with ICCs 0.71–0.89.Data Conclusion: ECG‐triggered PCASL‐bSSFP imaging of the lung at 1.5T can provide very good image quality and quantitative perfusion maps even under FB. The course of labeled blood through the lung shows a strong dependence on the individuals' cardiac cycle duration.Level of Evidence: 2Technical Efficacy Stage: 2 J. MAGN. RESON. IMAGING 2020;52:1767–1782.Keywords
This publication has 37 references indexed in Scilit:
- Ultra-fast steady state free precession and its application to in vivo 1 H morphological and functional lung imaging at 1.5 teslaMagnetic Resonance in Medicine, 2013
- Quantitative and Semiquantitative Measures of Regional Pulmonary Microvascular Perfusion by Magnetic Resonance Imaging and Their Relationships to Global Lung Perfusion and Lung Diffusing CapacityInvestigative Radiology, 2013
- Multifunctional Profiling of Non–Small Cell Lung Cancer Using 18F-FDG PET/CT and Volume Perfusion CTJournal of Nuclear Medicine, 2012
- SNM Practice Guideline for Lung Scintigraphy 4.0Journal of Nuclear Medicine Technology, 2012
- Non‐contrast‐enhanced perfusion and ventilation assessment of the human lung by means of fourier decomposition in proton MRIMagnetic Resonance in Medicine, 2009
- Characterizing pulmonary blood flow distribution measured using arterial spin labelingNMR in Biomedicine, 2009
- Strategies for reducing respiratory motion artifacts in renal perfusion imaging with arterial spin labelingMagnetic Resonance in Medicine, 2009
- Continuous flow‐driven inversion for arterial spin labeling using pulsed radio frequency and gradient fieldsMagnetic Resonance in Medicine, 2008
- Dynamic perfusion MRI: Capability for evaluation of disease severity and progression of pulmonary arterial hypertension in patients with connective tissue diseaseJournal of Magnetic Resonance Imaging, 2008
- Quantification of regional pulmonary blood flow using ASL‐FAIRERMagnetic Resonance in Medicine, 2006