When is reacquisition necessary due to high extra-cardiac uptake in myocardial perfusion scintigraphy?
Authors:
- Allan JohansenAJAllan Johansen
- Milan LomskyMLMilan Lomsky
- Oke GerkeOGOke Gerke
- Lars EdenbrandtLELars Edenbrandt
- Lena JohanssonLJLena Johansson
- Gunhild HansenGHGunhild Hansen
- Birgitte JensenBJBirgitte Jensen
- Maria Sallerup ReidMRMaria Sallerup Reid
- Lise-Lott JohanssonLJLise-Lott Johansson
- Camilla OlofssonCOCamilla Olofsson
- David MinarikDMDavid Minarik
- Karin NyströmKNKarin Nyström
Open Access
- 25 March 2013
- journal article
- Published by Springer Nature in EJNMMI Research
- Vol. 3 (1) , 20
Abstract
Background: Technetium-labeled agents, which are most often used for assessing myocardial perfusion in myocardial perfusion scintigraphy (MPS), are cleared by the liver and excreted by the biliary system. Spillover from extra-cardiac activity into the myocardium, especially the inferior wall, might conceal defects and lower the diagnostic accuracy of the study. The objective was to determine rules of thumb for when reacquisition is useful due to high extra-cardiac uptake, i.e., when interpretation of the studies was affected by poor image quality. Methods: Patients admitted to MPS at any of the three study sites, who also underwent a reacquisition due to high extra-cardiac uptake were included. Image quality was assessed by ten technologists on a scale ranging from 1 to 5. Interpretations regarding the presence/absence of ischemia/infarction, including the certainty of the diagnosis, were made by three physicians. Results: There was a statistically significant increase in image quality between the first and the repeated acquisition (1,256 cases of increased quality at the repeated study (66%), 134 cases of decreased quality at the repeated study (7%), 510 cases of unchanged quality (27%) P < 0.0001). The number of equivocal studies, interpreted by physicians, decreased when evaluating the repeated studies compared to the first studies for all physicians, both for the interpretations of ischemia and for infarction. Receiver operating characteristic analyses revealed that for both endpoints (ischemia, infarction) and all physicians, the optimal cutoff point for performing a reacquisition was between quality categories 2 and 3. Conclusion: This study indicates that repeat acquisition is useful when (1) the intensity of the extra-cardiac uptake is equal to or higher than the cardiac uptake when there is no separation between the extra-cardiac uptake and the inferior cardiac wall and (2) when the intensity of the extra-cardiac uptake is higher than the cardiac uptake when there is a separation between the extra-cardiac uptake and the inferior wall of less than one cardiac wall.Keywords
This publication has 15 references indexed in Scilit:
- Impact of ischaemia and scar on the therapeutic benefit derived from myocardial revascularization vs. medical therapy among patients undergoing stress-rest myocardial perfusion scintigraphyEuropean Heart Journal, 2011
- Randomized, single-blind, factorial design study of the interaction of food and time on intestinal activity in 99mTc-tetrofosmin stress myocardial perfusion scintigraphyNuclear Medicine Communications, 2008
- Feasibility and Diagnostic Accuracy of a Gated SPECT Early-Imaging Protocol: A Multicenter Study of the Myoview Imaging Optimization GroupJournal of Nuclear Medicine, 2007
- Artifacts and pitfalls in myocardial perfusion imaging.2006
- EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiologyEuropean Journal of Nuclear Medicine and Molecular Imaging, 2005
- Risk assessment using single-photon emission computed tomographic technetium-99m sestamibi imagingJACC, 1998
- Effective risk stratification using exercise myocardial perfusion SPECT in women: Gender-related differences in prognostic nuclear testingJACC, 1996
- Exercise Myocardial Perfusion SPECT in Patients Without Known Coronary Artery DiseaseCirculation, 1996
- A Monte Carlo investigation of artifacts caused by liver uptake in single-photon emission computed tomography perfusion imaging with technetium 99m-labeled agentsJournal of Nuclear Cardiology, 1996
- Measuring nominal scale agreement among many raters.Psychological Bulletin, 1971