Milan Lomsky
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Milan Lomsky has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Lars Edenbrandt
Skåne University Hospital, Malmö, Sweden
2 shared publications - Allan Johansen
Department of Nuclear Medicine, Odense University Hospital, Odense, Denmark
1 shared publication - Birgitte Jensen
Department of Nuclear Medicine, Odense University Hospital, Odense, Denmark
1 shared publication - Camilla Olofsson
Nuclear Medicine Unit, Skåne University Hospital, Lund University, Malmo, Sweden
1 shared publication - David Minarik
Radiation Physics, Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, 221 85, Lund, Sweden
1 shared publication - Elin Trägårdh
Clinical Physiology and Nuclear Medicine, Skåne University Hospital, Lund University, Malmö, Sweden
1 shared publication
Latest Publications
- Open Access
- 25 March 2013
- Published by Springer Nature in EJNMMI Research
- Vol. 3 (1) , 20
When is reacquisition necessary due to high extra-cardiac uptake in myocardial perfusion scintigraphy?
Background: Technetium-labeled agents, which are most often used for assessing myocardial perfusion in myocardial perfusion scintigraphy (MPS), are cleared by the liver and excreted by the biliary system. Spillover from extra-cardiac activity into the myocardium, especially the inferior wall, might conceal defects and lower the diagnostic accuracy of the study. The objective was to determine rules of thumb for when reacquisition is useful due to high extra-cardiac uptake, i.e., when interpretation of the studies was affected by poor image quality. Methods: Patients admitted to MPS at any of the three study sites, who also underwent a reacquisition due to high extra-cardiac uptake were included. Image quality was assessed by ten technologists on a scale ranging from 1 to 5. Interpretations regarding the presence/absence of ischemia/infarction, including the certainty of the diagnosis, were made by three physicians. Results: There was a statistically significant increase in image quality between the first and the repeated acquisition (1,256 cases of increased quality at the repeated study (66%), 134 cases of decreased quality at the repeated study (7%), 510 cases of unchanged quality (27%) P < 0.0001). The number of equivocal studies, interpreted by physicians, decreased when evaluating the repeated studies compared to the first studies for all physicians, both for the interpretations of ischemia and for infarction. Receiver operating characteristic analyses revealed that for both endpoints (ischemia, infarction) and all physicians, the optimal cutoff point for performing a reacquisition was between quality categories 2 and 3. Conclusion: This study indicates that repeat acquisition is useful when (1) the intensity of the extra-cardiac uptake is equal to or higher than the cardiac uptake when there is no separation between the extra-cardiac uptake and the inferior cardiac wall and (2) when the intensity of the extra-cardiac uptake is higher than the cardiac uptake when there is a separation between the extra-cardiac uptake and the inferior wall of less than one cardiac wall.
- 25 March 2013
- Published by Springer Nature in EJNMMI Research
- Vol. 3 (1) , 20
Open AccessWhen is reacquisition necessary due to high extra-cardiac uptake in myocardial perfusion scintigraphy?
Background: Technetium-labeled agents, which are most often used for assessing myocardial perfusion in myocardial perfusion scintigraphy (MPS), are cleared by the liver and excreted by the biliary system. Spillover from extra-cardiac activity into the myocardium, especially the inferior wall, might conceal defects and lower the diagnostic accuracy of the study. The objective was to determine rules of thumb for when reacquisition is useful due to high extra-cardiac uptake, i.e., when interpretation of the studies was affected by poor image quality. Methods: Patients admitted to MPS at any of the three study sites, who also underwent a reacquisition due to high extra-cardiac uptake were included. Image quality was assessed by ten technologists on a scale ranging from 1 to 5. Interpretations regarding the presence/absence of ischemia/infarction, including the certainty of the diagnosis, were made by three physicians. Results: There was a statistically significant increase in image quality between the first and the repeated acquisition (1,256 cases of increased quality at the repeated study (66%), 134 cases of decreased quality at the repeated study (7%), 510 cases of unchanged quality (27%) P < 0.0001). The number of equivocal studies, interpreted by physicians, decreased when evaluating the repeated studies compared to the first studies for all physicians, both for the interpretations of ischemia and for infarction. Receiver operating characteristic analyses revealed that for both endpoints (ischemia, infarction) and all physicians, the optimal cutoff point for performing a reacquisition was between quality categories 2 and 3. Conclusion: This study indicates that repeat acquisition is useful when (1) the intensity of the extra-cardiac uptake is equal to or higher than the cardiac uptake when there is no separation between the extra-cardiac uptake and the inferior cardiac wall and (2) when the intensity of the extra-cardiac uptake is higher than the cardiac uptake when there is a separation between the extra-cardiac uptake and the inferior wall of less than one cardiac wall.
- 31 January 2011
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 31 (3) , 240-245
Clinical data do not improve artificial neural network interpretation of myocardial perfusion scintigraphy
Artificial neural networks interpretation of myocardial perfusion scintigraphy (MPS) has so far been based on image data alone. Physicians reporting MPS often combine image and clinical data. The aim was to evaluate whether neural network interpretation would be improved by adding clinical data to image data. Four hundred and eighteen patients were used for training and 532 patients for testing the neural networks. First, the network was trained with image data alone and thereafter with image data in combination with clinical parameters (age, gender, previous infarction, percutaneous coronary intervention, coronary artery bypass grafting, typical chest pain, present smoker, hypertension, hyperlipidaemia, diabetes, peripheral vascular disease and positive family history). Expert interpretation was used as gold standard. Receiver operating characteristic (ROC) curves were calculated, and the ROC areas for the networks trained with and without clinical data were compared for the diagnosis of myocardial infarction and ischaemia. There was no statistically significant difference in ROC area for the diagnosis of myocardial infarction between the neural network trained with the combination of clinical and image data (95.8%) and with image data alone (95.2%). For the diagnosis of ischaemia, there was no statistically significant difference in ROC area between the neural network trained with the combination of clinical and image data (87.9%) and with image data alone (88.0%). Neural network interpretation of MPS is not improved when clinical data are added to perfusion and functional data. One reason for this could be that experts base their interpretations of MPS mainly on the images and to a lesser degree on clinical data.
- 31 January 2011
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 31 (3) , 240-245
Clinical data do not improve artificial neural network interpretation of myocardial perfusion scintigraphy
Artificial neural networks interpretation of myocardial perfusion scintigraphy (MPS) has so far been based on image data alone. Physicians reporting MPS often combine image and clinical data. The aim was to evaluate whether neural network interpretation would be improved by adding clinical data to image data. Four hundred and eighteen patients were used for training and 532 patients for testing the neural networks. First, the network was trained with image data alone and thereafter with image data in combination with clinical parameters (age, gender, previous infarction, percutaneous coronary intervention, coronary artery bypass grafting, typical chest pain, present smoker, hypertension, hyperlipidaemia, diabetes, peripheral vascular disease and positive family history). Expert interpretation was used as gold standard. Receiver operating characteristic (ROC) curves were calculated, and the ROC areas for the networks trained with and without clinical data were compared for the diagnosis of myocardial infarction and ischaemia. There was no statistically significant difference in ROC area for the diagnosis of myocardial infarction between the neural network trained with the combination of clinical and image data (95.8%) and with image data alone (95.2%). For the diagnosis of ischaemia, there was no statistically significant difference in ROC area between the neural network trained with the combination of clinical and image data (87.9%) and with image data alone (88.0%). Neural network interpretation of MPS is not improved when clinical data are added to perfusion and functional data. One reason for this could be that experts base their interpretations of MPS mainly on the images and to a lesser degree on clinical data.
- Open Access
- 25 February 2008
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 28 (3) , 169-173
Normal limits for left ventricular ejection fraction and volumes determined by gated single photon emission computed tomography – a comparison between two quantification methods
Summary: To compare gender‐related normal limits for left ventricular (LV) ejection fraction (EF), end‐diastolic and end‐systolic volumes (EDV and ESV), obtained using two myocardial perfusion‐gated single photon emission computed tomography (SPECT) quantification methods. A total of 185 patients were retrospectively selected from a consecutive series of patients examined for coronary artery disease (CAD) or for management of known CAD. Patients were included in the study group if they had normal or probably normal results with stress and rest perfusion imaging and if the combined interpretation of perfusion studies and gated rest studies showed no signs or suspicion of myocardial infarction. The gated SPECT studies were performed using a 2‐day stress/gated rest Tc‐99m sestamibi protocol. All patient studies were processed using CAFU and quantitative‐gated SPECT (QGS), the two software packages for quantification of gated SPECT images. The lower normal limits for EF were higher for CAFU compared with QGS for both women (59% versus 53%) and men (54% versus 47%). The upper normal limits for EDV were also higher for CAFU compared with QGS for both women (133 versus 107 ml) and men (182 versus 161 ml). The differences between the software packages were small for ESV (women 44 versus 44 ml; men 69 versus 74 ml). Gender‐specific normal limits need to be applied for LV EF and volumes determined by gated SPECT. Separate criteria for abnormal LV EF and EDV need to be used for women and men depending on the software package used.
- 25 February 2008
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 28 (3) , 169-173
Open AccessNormal limits for left ventricular ejection fraction and volumes determined by gated single photon emission computed tomography – a comparison between two quantification methods
Summary: To compare gender‐related normal limits for left ventricular (LV) ejection fraction (EF), end‐diastolic and end‐systolic volumes (EDV and ESV), obtained using two myocardial perfusion‐gated single photon emission computed tomography (SPECT) quantification methods. A total of 185 patients were retrospectively selected from a consecutive series of patients examined for coronary artery disease (CAD) or for management of known CAD. Patients were included in the study group if they had normal or probably normal results with stress and rest perfusion imaging and if the combined interpretation of perfusion studies and gated rest studies showed no signs or suspicion of myocardial infarction. The gated SPECT studies were performed using a 2‐day stress/gated rest Tc‐99m sestamibi protocol. All patient studies were processed using CAFU and quantitative‐gated SPECT (QGS), the two software packages for quantification of gated SPECT images. The lower normal limits for EF were higher for CAFU compared with QGS for both women (59% versus 53%) and men (54% versus 47%). The upper normal limits for EDV were also higher for CAFU compared with QGS for both women (133 versus 107 ml) and men (182 versus 161 ml). The differences between the software packages were small for ESV (women 44 versus 44 ml; men 69 versus 74 ml). Gender‐specific normal limits need to be applied for LV EF and volumes determined by gated SPECT. Separate criteria for abnormal LV EF and EDV need to be used for women and men depending on the software package used.