Management of patients explanted for implantable cardioverter defibrillator infections: Bridge therapy with external temporary ICD
- 9 September 2021
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 44 (11) , 1884-1889
Abstract
Aims and methods In case of CIED (Cardiac Implantable Electronic Device)-related infections it is mandatory to completely remove the device and administer prolonged antibiotic therapy. The management of patients explanted for an implantable defibrillator (ICD) infection is complex especially in patients needing anti-bradycardia pacing or tachyarrhythmia protection. We tested the efficacy and safety of a conventional ICD externally connected to a transvenous dual-coil lead as bridging therapy before the re-implant, comparing outcomes with a historical cohort of patients (N = 113) treated with temporary transvenous pacing. We enrolled eighteen patients explanted for ICD infection and needing prolonged antibiotic therapy in three high-volume Italian centers. They received an external ICD stand-by for a mean of 16,5 (4-30) days before the re-implant. Results No patient experienced malfunction of the system, with a significant reduction of this complication versus temporary transfemoral pacing (37%, p = 0.004). Post-procedural occurrence of other complications (infection, relevant local bleeding, ventricular tachycardia during insertion of the lead, cardiac perforation, venous thromboembolism) was low and not different in the two groups. One patient experienced an electrical storm, effectively recognized by the external ICD and treated with ATPs and shocks. Conclusions an approach with an external ICD seems to be a safe and viable option as bridging therapy in patients requiring ICD explant for CIED infection. This article is protected by copyright. All rights reservedKeywords
This publication has 15 references indexed in Scilit:
- Long-Term Risk for Device-Related Complications and Reoperations After Implantable Cardioverter-Defibrillator ImplantationAnnals of Internal Medicine, 2016
- Worldwide experience with a totally subcutaneous implantable defibrillator: early results from the EFFORTLESS S-ICD RegistryEuropean Heart Journal, 2014
- Safety and Efficacy of a Totally Subcutaneous Implantable-Cardioverter DefibrillatorCirculation, 2013
- Bridge to Recovery or Permanent System Implantation: An Eight‐Year Single‐Center Experience in Transvenous Semipermanent PacingPacing and Clinical Electrophysiology, 2013
- Utility and safety of temporary pacing using active fixation leads and externalized re-usable permanent pacemakers after lead extractionEP Europace, 2013
- Aggregate National Experience With the Wearable Cardioverter-DefibrillatorJACC, 2010
- Bridging a Temporary High Risk of Sudden Arrhythmic Death. Experience with the Wearable Cardioverter Defibrillator (WCD)Pacing and Clinical Electrophysiology, 2010
- Percutaneous Lead Implantation Connected to an External Device in Stimulation‐Dependent Patients with Systemic Infection—A Prospective and Controlled StudyPacing and Clinical Electrophysiology, 2006
- Clinical Efficacy of a Wearable Defibrillator in Acutely Terminating Episodes of Ventricular Fibrillation Using Biphasic ShocksPacing and Clinical Electrophysiology, 2003
- Analysis of pacemaker malfunction and complications of temporary pacing in the coronary care unitThe American Journal of Cardiology, 1982