Gabriele Dell'ERa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Gabriele Dell'ERa has a total of 200 co-authors. Here are the top co-authors by number of shared publications:
- Giuseppe Patti
Department of Thoracic, Heart and Vascular Diseases, Maggiore Della Carità Hospital, Novara, Italy
10 shared publications Giuseppe Patti
Univ Piemonte Orientale Amedeo Avogadro, Novara, Italy
7 shared publicationsAnna Degiovanni
Maggiore Della Carità Hospital Novara Italy
6 shared publicationsChiara Ghiglieno
Department of Cardiology, University of Eastern Piedmont , Novara
6 shared publications- Matteo Ziacchi
Institute of Cardiology, IRCCS Azienda Ospedaliero Universitaria di Bologna , Bologna
6 shared publications - Pietro Palmisano
Cardiology Unit, "Card. G. Panico" Hospital, Tricase, Italy
5 shared publications
Latest Publications
- Open Access
- 17 November 2026
- Published by Oxford University Press (OUP) in EP Europace
Conduction System Pacing versus Conventional Right Ventricular Pacing After Cardiac Surgery – A Multicenter Cohort Study
- 17 November 2026
- Published by Oxford University Press (OUP) in EP Europace
Open AccessConduction System Pacing versus Conventional Right Ventricular Pacing After Cardiac Surgery – A Multicenter Cohort Study
- Open Access
- 7 May 2026
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 37 (7) , 1432-1441
Impact of Left Bundle Branch Area Pacing on Echocardiographic Parameters and Symptoms: Data From the Conduction System Pacing Italian Network Group (C‐SING) Study
Introduction: Left bundle branch area pacing (LBBAP) has emerged as a physiologic alternative to conventional right ventricular and biventricular pacing, yet large real‐world evidence remains limited. We aimed to assess changes in ventricular function and symptoms after LBBAP in patients with different clinical indications. Methods and Results: Consecutive patients discharged with confirmed LBBAP across 29 Italian centers underwent evaluation of echocardiographic parameters and New York Heart Association (NYHA) functional class at follow‐up. A total of 697 patients were included: 532 with a bradycardia indication and 165 with a heart failure (HF) indication, assessed at a median follow‐up of 12.4 months. In the bradycardia group, left ventricular ejection fraction (LVEF) showed a slight improvement from 55% (interquartile range, 50–60) to 56% (52–60) ( p = 0.027). Paced‐induced cardiomyopathy (PICM), defined as a ≥ 10% absolute LVEF reduction to < 50%, occurred in 3% of patients. Loss of LBBAP capture ( p = 0.025) and lower LBBAP percentage ( p = 0.024) were independent predictors of PICM. In the HF group, LVEF improved from 35% (30–41) to 45% (36–52) ( p < 0.001). Overall, 61.8% were classified as responders (LVEF increase ≥ 5%), rising to 73.8% among patients with ≥ 12 months of follow‐up. Higher LBBAP pacing percentage and absence of coronary artery disease independently predicted response. NYHA functional class improved significantly in both groups. Conclusions: In this large real‐world cohort, LBBAP was associated with meaningful improvements in ventricular function and symptoms in both bradycardia and HF populations. A high percentage of effective LBBAP capture is essential for optimizing outcomes, supporting its role as an effective physiologic pacing strategy.
- 7 May 2026
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 37 (7) , 1432-1441
Open AccessImpact of Left Bundle Branch Area Pacing on Echocardiographic Parameters and Symptoms: Data From the Conduction System Pacing Italian Network Group (C‐SING) Study
Introduction: Left bundle branch area pacing (LBBAP) has emerged as a physiologic alternative to conventional right ventricular and biventricular pacing, yet large real‐world evidence remains limited. We aimed to assess changes in ventricular function and symptoms after LBBAP in patients with different clinical indications. Methods and Results: Consecutive patients discharged with confirmed LBBAP across 29 Italian centers underwent evaluation of echocardiographic parameters and New York Heart Association (NYHA) functional class at follow‐up. A total of 697 patients were included: 532 with a bradycardia indication and 165 with a heart failure (HF) indication, assessed at a median follow‐up of 12.4 months. In the bradycardia group, left ventricular ejection fraction (LVEF) showed a slight improvement from 55% (interquartile range, 50–60) to 56% (52–60) ( p = 0.027). Paced‐induced cardiomyopathy (PICM), defined as a ≥ 10% absolute LVEF reduction to < 50%, occurred in 3% of patients. Loss of LBBAP capture ( p = 0.025) and lower LBBAP percentage ( p = 0.024) were independent predictors of PICM. In the HF group, LVEF improved from 35% (30–41) to 45% (36–52) ( p < 0.001). Overall, 61.8% were classified as responders (LVEF increase ≥ 5%), rising to 73.8% among patients with ≥ 12 months of follow‐up. Higher LBBAP pacing percentage and absence of coronary artery disease independently predicted response. NYHA functional class improved significantly in both groups. Conclusions: In this large real‐world cohort, LBBAP was associated with meaningful improvements in ventricular function and symptoms in both bradycardia and HF populations. A high percentage of effective LBBAP capture is essential for optimizing outcomes, supporting its role as an effective physiologic pacing strategy.
- Open Access
- 27 December 2025
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 37 (3) , 475-483
Implantation Success, Electrical Performance, and Safety of an Active Fixation Stylet‐Driven Lead for LBBAP in Clinical Practice: A Multicenter Experience
Background: Left bundle branch area pacing (LBBAP) has emerged as a promising physiological pacing strategy. However, its feasibility and safety using conventional stylet‐driven leads (SDL) such as INGEVITY+ remain under investigation. Objective: To evaluate the clinical performance, safety, and follow‐up outcomes of LBBAP using the INGEVITY+ lead in a real‐world electrophysiology setting. Methods: From 2021 to 2024, 207 consecutive patients underwent LBBAP implant attempts using the INGEVITY+ lead across 19 centers. Of these, 146 had bradycardia indications, and 61 had heart failure indications. A control group of 200 patients received standard right ventricular (RV) pacing with the same lead. Procedural outcomes, electrical parameters, complications, and mid‐term lead performance were assessed. Results: LBBAP was successfully achieved in 201 (97%) cases. Procedural and fluoroscopy times were slightly longer for LBBAP than for RV pacing. Acute complications included one helix fracture, one atrioventricular block, and one septal perforation. During a median follow‐up of 9 months, no lead fractures were reported; lead dislodgment occurred in three cases. Kaplan–Meier analysis showed no significant difference in time to first lead‐related complication between the LBBAP and RV pacing groups (hazard ratio: 4.69, 95%CI: 0.63–34.90, p = 0.139). Electrical performance remained stable, with 98% of retained leads maintaining capture thresholds ≤ 2 V and 92% with sensed amplitudes ≥ 5 mV. Conclusions: LBBAP using the INGEVITY + SDL is feasible and safe in clinical practice, with excellent implant success and stable mid‐term electrical performance. These findings support its use as a viable conduction system pacing strategy.
- 27 December 2025
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 37 (3) , 475-483
Open AccessImplantation Success, Electrical Performance, and Safety of an Active Fixation Stylet‐Driven Lead for LBBAP in Clinical Practice: A Multicenter Experience
Background: Left bundle branch area pacing (LBBAP) has emerged as a promising physiological pacing strategy. However, its feasibility and safety using conventional stylet‐driven leads (SDL) such as INGEVITY+ remain under investigation. Objective: To evaluate the clinical performance, safety, and follow‐up outcomes of LBBAP using the INGEVITY+ lead in a real‐world electrophysiology setting. Methods: From 2021 to 2024, 207 consecutive patients underwent LBBAP implant attempts using the INGEVITY+ lead across 19 centers. Of these, 146 had bradycardia indications, and 61 had heart failure indications. A control group of 200 patients received standard right ventricular (RV) pacing with the same lead. Procedural outcomes, electrical parameters, complications, and mid‐term lead performance were assessed. Results: LBBAP was successfully achieved in 201 (97%) cases. Procedural and fluoroscopy times were slightly longer for LBBAP than for RV pacing. Acute complications included one helix fracture, one atrioventricular block, and one septal perforation. During a median follow‐up of 9 months, no lead fractures were reported; lead dislodgment occurred in three cases. Kaplan–Meier analysis showed no significant difference in time to first lead‐related complication between the LBBAP and RV pacing groups (hazard ratio: 4.69, 95%CI: 0.63–34.90, p = 0.139). Electrical performance remained stable, with 98% of retained leads maintaining capture thresholds ≤ 2 V and 92% with sensed amplitudes ≥ 5 mV. Conclusions: LBBAP using the INGEVITY + SDL is feasible and safe in clinical practice, with excellent implant success and stable mid‐term electrical performance. These findings support its use as a viable conduction system pacing strategy.
- Open Access
- 18 November 2025
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 36 (12) , 3343-3352
Predictive Value of Left Atrial Strain for Atrial High‐Rate Episodes in Patients With Permanent Cardiac Pacing
Background: Atrial high‐rate episodes (AHREs) detected by cardiac implantable electronic devices are associated with a higher risk of developing subsequent atrial fibrillation. Thus, risk stratification for AHREs is essential to guide patient management and improve outcome. Left atrial strain (LAS) parameters have been proposed as markers of atrial mechanical dysfunction, but their predictive value for AHRE prediction is not definitely established. Methods: We performed a retrospective, single‐center study on consecutive patients undergoing pacemaker implantation. Pre‐implant echocardiographic assessment included the measurement of LAS parameters. AHREs were defined as asymptomatic episodes with atrial rate > 175 bpm lasting ≥ 5 min by pacemaker evaluation. Primary endpoint was the predictive accuracy of LAS values for AHRE occurrence during follow‐up. Results: A total of 269 patients (age 78.0 ± 11.2 years; CHA₂DS₂‐VASc score 3.8 ± 1.6) were included. Median follow‐up was 28 months. ROC analysis showed that LAS contraction had superior predictive value for AHREs than LAS reservoir (AUC 0.75 vs. 0.63, p = 0.001). A 10.2% cutoff of LAS contraction had sensitivity of 77%, specificity of 64%, and negative predictive value (NPV) of 90% for AHRE occurrence. Kaplan–Meier analysis showed a higher AHRE incidence in patients with LAS contraction < 10.2% (45% vs. 10% in those with LAS contraction ≥ 10.2%; log‐rank p < 0.001). Multivariate analysis confirmed LAS contraction < 10.2% as an independent predictor of AHREs (adjusted hazard ratio [aHR] 5.0 (95% CI 2.7–9.3); p < 0.001). The risk increase was even higher when a LAS contraction < 10.2% was associated with age ≥ 70 years (aHR 16.3; 95% CI 2.0–131.7; p = 0.009). Conclusions: In patients with a permanent pacemaker, pre‐implant LAS contraction by echocardiography is an independent predictor of future AHRE development, with a very high NPV. The evaluation of LAS contraction may represent a valuable tool for identifying in clinical practice those individuals at low risk for AHREs.
- 18 November 2025
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 36 (12) , 3343-3352
Open AccessPredictive Value of Left Atrial Strain for Atrial High‐Rate Episodes in Patients With Permanent Cardiac Pacing
Background: Atrial high‐rate episodes (AHREs) detected by cardiac implantable electronic devices are associated with a higher risk of developing subsequent atrial fibrillation. Thus, risk stratification for AHREs is essential to guide patient management and improve outcome. Left atrial strain (LAS) parameters have been proposed as markers of atrial mechanical dysfunction, but their predictive value for AHRE prediction is not definitely established. Methods: We performed a retrospective, single‐center study on consecutive patients undergoing pacemaker implantation. Pre‐implant echocardiographic assessment included the measurement of LAS parameters. AHREs were defined as asymptomatic episodes with atrial rate > 175 bpm lasting ≥ 5 min by pacemaker evaluation. Primary endpoint was the predictive accuracy of LAS values for AHRE occurrence during follow‐up. Results: A total of 269 patients (age 78.0 ± 11.2 years; CHA₂DS₂‐VASc score 3.8 ± 1.6) were included. Median follow‐up was 28 months. ROC analysis showed that LAS contraction had superior predictive value for AHREs than LAS reservoir (AUC 0.75 vs. 0.63, p = 0.001). A 10.2% cutoff of LAS contraction had sensitivity of 77%, specificity of 64%, and negative predictive value (NPV) of 90% for AHRE occurrence. Kaplan–Meier analysis showed a higher AHRE incidence in patients with LAS contraction < 10.2% (45% vs. 10% in those with LAS contraction ≥ 10.2%; log‐rank p < 0.001). Multivariate analysis confirmed LAS contraction < 10.2% as an independent predictor of AHREs (adjusted hazard ratio [aHR] 5.0 (95% CI 2.7–9.3); p < 0.001). The risk increase was even higher when a LAS contraction < 10.2% was associated with age ≥ 70 years (aHR 16.3; 95% CI 2.0–131.7; p = 0.009). Conclusions: In patients with a permanent pacemaker, pre‐implant LAS contraction by echocardiography is an independent predictor of future AHRE development, with a very high NPV. The evaluation of LAS contraction may represent a valuable tool for identifying in clinical practice those individuals at low risk for AHREs.
- Open Access
- 3 December 2024
- Published by Elsevier in International Journal of Cardiology
- Vol. 421, 132879
Real-world adoption of left bundle branch area pacing: Insights from the Conduction-System pacing Italian Network Group (C-SING)
- 3 December 2024
- Published by Elsevier in International Journal of Cardiology
- Vol. 421, 132879
Open AccessReal-world adoption of left bundle branch area pacing: Insights from the Conduction-System pacing Italian Network Group (C-SING)
- Open Access
- 1 August 2024
- Published by Oxford University Press (OUP) in ESC Heart Failure
- Vol. 11 (6) , 3993-3999
Wearable Defibrillator to Improve Accuracy in Selecting Candidates to Implantable Defibrillator: A Real-World Experience
Aims: The indication for implantable cardioverter defibrillator (ICD) for sudden cardiac death (SCD) prevention relies mostly on left ventricular ejection fraction (LVEF) ≤ 35%. The use of a wearable cardioverter defibrillator (WCD) in the case of dynamic alterations of LVEF may help avoid an improper early ICD implant when a favourable evolution in the post-acute phase is observed and may help reduce costs. Methods: This parallel cohort retrospective study included patients with heart failure with reduced ejection fraction (HFrEF) at high risk of arrhythmias recruited in the acute phase and divided into an early ICD cohort and a WCD cohort for primary prevention during the waiting period established by European Society of Cardiology guidelines. Results: A total of 41 consecutive patients were enrolled: 26 in the WCD group and 15 in the early ICD group. Age, LVEF at baseline, causes of HFrEF and drug therapy in the two cohorts were similar. During the waiting period after the inclusion, three patients (11.5%) in the WCD cohort and four (26.7%) in the early ICD cohort developed relevant ventricular arrhythmias (P = 0.22); none of them had subsequent LVEF recovery. At the end of the waiting period, 13 patients (50%) in the WCD group and 7 (46.7%) in the early ICD group experienced LVEF recovery (P = 0.84). The average cost per patient at the end of the waiting period was €23 934 in the early ICD cohort versus €19 167 in the WCD cohort (−19.9%). This cost savings from WCD use appears even higher when projected over a 10 year period (−41.2%). Conclusions: WCD may represent a cost-effective strategy to more accurately select candidates for the primary prevention ICD implant among high-risk patients with HFrEF. ICD use provides effective protection from SCD and reduces costs compared with an extensive early ICD implant.
- 1 August 2024
- Published by Oxford University Press (OUP) in ESC Heart Failure
- Vol. 11 (6) , 3993-3999
Open AccessWearable Defibrillator to Improve Accuracy in Selecting Candidates to Implantable Defibrillator: A Real-World Experience
Aims: The indication for implantable cardioverter defibrillator (ICD) for sudden cardiac death (SCD) prevention relies mostly on left ventricular ejection fraction (LVEF) ≤ 35%. The use of a wearable cardioverter defibrillator (WCD) in the case of dynamic alterations of LVEF may help avoid an improper early ICD implant when a favourable evolution in the post-acute phase is observed and may help reduce costs. Methods: This parallel cohort retrospective study included patients with heart failure with reduced ejection fraction (HFrEF) at high risk of arrhythmias recruited in the acute phase and divided into an early ICD cohort and a WCD cohort for primary prevention during the waiting period established by European Society of Cardiology guidelines. Results: A total of 41 consecutive patients were enrolled: 26 in the WCD group and 15 in the early ICD group. Age, LVEF at baseline, causes of HFrEF and drug therapy in the two cohorts were similar. During the waiting period after the inclusion, three patients (11.5%) in the WCD cohort and four (26.7%) in the early ICD cohort developed relevant ventricular arrhythmias (P = 0.22); none of them had subsequent LVEF recovery. At the end of the waiting period, 13 patients (50%) in the WCD group and 7 (46.7%) in the early ICD group experienced LVEF recovery (P = 0.84). The average cost per patient at the end of the waiting period was €23 934 in the early ICD cohort versus €19 167 in the WCD cohort (−19.9%). This cost savings from WCD use appears even higher when projected over a 10 year period (−41.2%). Conclusions: WCD may represent a cost-effective strategy to more accurately select candidates for the primary prevention ICD implant among high-risk patients with HFrEF. ICD use provides effective protection from SCD and reduces costs compared with an extensive early ICD implant.
- 29 July 2024
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 25 (11) , 1590-1598
Determinants of invasive left atrial pressure in patients with atrial fibrillation
Aims: Estimation of left ventricular (LV) filling pressures in patients with a history of atrial fibrillation (AF) is challenging due to lack of reliable parameters. This study investigates the association between cardiac structure and function and invasive mean left atrial pressure (LAP). Methods and results: This is a multi-centre prospective study enrolling patients undergoing transcatheter ablation for AF. The invasive measurement of LAP was performed at the time of the procedure while the echocardiography within the previous 24 h. A mean LAP ≥ 15 mmHg was considered as increased. Overall, 101 patients were included (mean age 65.8 ± 8.5 years, 68% male, mean LV ejection fraction 56.6 ± 8.0%). No significant differences regarding clinical characteristics were detected between the group of patients with normal (n = 47) or increased LAP (n = 54). The latter showed lower values of LV global longitudinal strain, larger left atrial volumes (LAVs) and worse right ventricular (RV) function. After multivariable adjustment, higher E/e′ ratio (P = 0.041) and minimal LAV index (LAVI min) (P = 0.031), lower peak atrial longitudinal strain (P = 0.030), and RV free wall longitudinal strain (P = 0.037), but not maximal LAV index (LAVI max) (P = 0.137), were significantly associated with mean LAP. The associations were not modified by cardiac rhythm. Overall, LAVI min showed the best diagnostic accuracy to predict elevated LAP (area under the curve 0.703). Conclusion: LA structure and function assessment well correlates with mean LAP in patients with a history of AF. These measures may be used in the assessment of filling pressure in these patients.
- 29 July 2024
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 25 (11) , 1590-1598
Determinants of invasive left atrial pressure in patients with atrial fibrillation
Aims: Estimation of left ventricular (LV) filling pressures in patients with a history of atrial fibrillation (AF) is challenging due to lack of reliable parameters. This study investigates the association between cardiac structure and function and invasive mean left atrial pressure (LAP). Methods and results: This is a multi-centre prospective study enrolling patients undergoing transcatheter ablation for AF. The invasive measurement of LAP was performed at the time of the procedure while the echocardiography within the previous 24 h. A mean LAP ≥ 15 mmHg was considered as increased. Overall, 101 patients were included (mean age 65.8 ± 8.5 years, 68% male, mean LV ejection fraction 56.6 ± 8.0%). No significant differences regarding clinical characteristics were detected between the group of patients with normal (n = 47) or increased LAP (n = 54). The latter showed lower values of LV global longitudinal strain, larger left atrial volumes (LAVs) and worse right ventricular (RV) function. After multivariable adjustment, higher E/e′ ratio (P = 0.041) and minimal LAV index (LAVI min) (P = 0.031), lower peak atrial longitudinal strain (P = 0.030), and RV free wall longitudinal strain (P = 0.037), but not maximal LAV index (LAVI max) (P = 0.137), were significantly associated with mean LAP. The associations were not modified by cardiac rhythm. Overall, LAVI min showed the best diagnostic accuracy to predict elevated LAP (area under the curve 0.703). Conclusion: LA structure and function assessment well correlates with mean LAP in patients with a history of AF. These measures may be used in the assessment of filling pressure in these patients.
- Open Access
- 9 April 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (8) , 2157
“Ablate and Pace” with Conduction System Pacing: Concomitant versus Delayed Atrioventricular Junction Ablation
Objectives: Conduction system pacing (CSP) and atrioventricular junction ablation (AVJA) improve the outcomes in patients with symptomatic, refractory atrial fibrillation (AF). In this setting, AVJA can be performed simultaneously with implantation or in a second procedure a few weeks after implantation. Comparison data on these two alternative strategies are lacking. Methods: A prospective, multicentre, observational study enrolled consecutive patients with symptomatic, refractory AF undergoing CSP and AVJA performed in a single procedure or in two separate procedures. Data on the long-term outcomes and healthcare resource utilization were prospectively collected. Results: A total of 147 patients were enrolled: for 105 patients, CSP implantation and AVJA were performed simultaneously (concomitant AVJA); in 42, AVJA was performed in a second procedure, with a mean of 28.8 ± 19.3 days from implantation (delayed AVJA). After a mean follow-up of 12 months, the rate of procedure-related complications was similar in both groups (3.8% vs. 2.4%; p = 0.666). Concomitant AVJA was associated with a lower number of procedure-related hospitalizations per patient (1.0 ± 0.1 vs. 2.0 ± 0.3; p < 0.001) and with a lower number of hospital treatment days per patient (4.7 ± 1.8 vs. 7.4 ± 1.9; p < 0.001). Conclusions: Concomitant AVJA resulted as being as safe as delayed AVJA and was associated with a lower utilization of healthcare resources.
- 9 April 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (8) , 2157
Open Access“Ablate and Pace” with Conduction System Pacing: Concomitant versus Delayed Atrioventricular Junction Ablation
Objectives: Conduction system pacing (CSP) and atrioventricular junction ablation (AVJA) improve the outcomes in patients with symptomatic, refractory atrial fibrillation (AF). In this setting, AVJA can be performed simultaneously with implantation or in a second procedure a few weeks after implantation. Comparison data on these two alternative strategies are lacking. Methods: A prospective, multicentre, observational study enrolled consecutive patients with symptomatic, refractory AF undergoing CSP and AVJA performed in a single procedure or in two separate procedures. Data on the long-term outcomes and healthcare resource utilization were prospectively collected. Results: A total of 147 patients were enrolled: for 105 patients, CSP implantation and AVJA were performed simultaneously (concomitant AVJA); in 42, AVJA was performed in a second procedure, with a mean of 28.8 ± 19.3 days from implantation (delayed AVJA). After a mean follow-up of 12 months, the rate of procedure-related complications was similar in both groups (3.8% vs. 2.4%; p = 0.666). Concomitant AVJA was associated with a lower number of procedure-related hospitalizations per patient (1.0 ± 0.1 vs. 2.0 ± 0.3; p < 0.001) and with a lower number of hospital treatment days per patient (4.7 ± 1.8 vs. 7.4 ± 1.9; p < 0.001). Conclusions: Concomitant AVJA resulted as being as safe as delayed AVJA and was associated with a lower utilization of healthcare resources.
- 1 April 2024
- Published by Wolters Kluwer Health in Journal of Cardiovascular Medicine
- Vol. 25 (6) , 450-456
Left bundle branch area versus conventional pacing after transcatheter valve implant for aortic stenosis: the LATVIA study
Background: Atrioventricular block (AVB) is a frequent complication in patients undergoing transcatheter aortic valve implantation (TAVI). Right apex ventricular pacing (RVP) represents the standard treatment but may induce cardiomyopathy over the long term. Left bundle branch area pacing (LBBAP) is a promising alternative, minimizing the risk of desynchrony. However, available evidence with LBBAP after TAVI is still low. Objective: To assess the feasibility and safety of LBBAP for AVB post-TAVI compared with RVP. Methods: Consecutive patients developing AVB early after TAVI were enrolled between 1 January 2022 and 31 December 2022 at three high-volume hospitals and received LBBAP or RVP. Data on procedure and at short-term follow-up (at least 3 months) were collected. Results: A total of 38 patients (61% men, mean age 83 ± 6 years) were included; 20 patients (53%) received LBBAP. Procedural success was obtained in all patients according to chosen pacing strategy. Electrical pacing performance at implant and after a mean follow-up of 4.2 ± 2.8 months was clinically equivalent for both pacing modalities. In the LBBAP group, procedural time was longer (70 ± 17 versus 58 ± 15 min in the RVP group, P = 0.02) and paced QRS was shorter (120 ± 19 versus 155 ± 12 ms at implant, P < 0.001; 119 ± 18 versus 157 ± 9 ms at follow-up, P < 0.001). Complication rates did not differ between the two groups. Conclusion: In patients with AVB after TAVI, LBBAP is feasible and safe, resulting in a narrow QRS duration, either acutely and during the follow-up, compared with RVP. Further studies are needed to evaluate if LBBAP reduces pacing-induced cardiomyopathy in this clinical setting.
- 1 April 2024
- Published by Wolters Kluwer Health in Journal of Cardiovascular Medicine
- Vol. 25 (6) , 450-456
Left bundle branch area versus conventional pacing after transcatheter valve implant for aortic stenosis: the LATVIA study
Background: Atrioventricular block (AVB) is a frequent complication in patients undergoing transcatheter aortic valve implantation (TAVI). Right apex ventricular pacing (RVP) represents the standard treatment but may induce cardiomyopathy over the long term. Left bundle branch area pacing (LBBAP) is a promising alternative, minimizing the risk of desynchrony. However, available evidence with LBBAP after TAVI is still low. Objective: To assess the feasibility and safety of LBBAP for AVB post-TAVI compared with RVP. Methods: Consecutive patients developing AVB early after TAVI were enrolled between 1 January 2022 and 31 December 2022 at three high-volume hospitals and received LBBAP or RVP. Data on procedure and at short-term follow-up (at least 3 months) were collected. Results: A total of 38 patients (61% men, mean age 83 ± 6 years) were included; 20 patients (53%) received LBBAP. Procedural success was obtained in all patients according to chosen pacing strategy. Electrical pacing performance at implant and after a mean follow-up of 4.2 ± 2.8 months was clinically equivalent for both pacing modalities. In the LBBAP group, procedural time was longer (70 ± 17 versus 58 ± 15 min in the RVP group, P = 0.02) and paced QRS was shorter (120 ± 19 versus 155 ± 12 ms at implant, P < 0.001; 119 ± 18 versus 157 ± 9 ms at follow-up, P < 0.001). Complication rates did not differ between the two groups. Conclusion: In patients with AVB after TAVI, LBBAP is feasible and safe, resulting in a narrow QRS duration, either acutely and during the follow-up, compared with RVP. Further studies are needed to evaluate if LBBAP reduces pacing-induced cardiomyopathy in this clinical setting.