Revision for measuring radon exhalation rate in open loop
Authors:
- 1 January 2013
- journal article
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 8 (01) , T01004
Abstract
We propose a novel method for quickly measuring the radon exhalation rate in open loop. We first obtain the temporal variation of radon concentration in the internal cell of the RAD7 by analyzing the work principle of RAD7. We then obtain the temporal variation of radon concentration in the ventilation-type accumulation chamber when the effects of leakage and back diffusion are neglected. This method uses the measured value before the radon concentration in the ventilation-type accumulation chamber reaches a steady state. The diameter of the air input tube to the ventilation-type accumulation is large enough to keep the differential pressure in the accumulation chamber and outdoors negligible. Short cycle time and large flow rate will be appropriate for reducing measurement error. Several radon exhalation rate measurements of the medium surface have been performed in the Radon Laboratory of the University of South China. The radon exhalation rates obtained by verification experiments are in good agreement with the reference value. This method can be applied to develop and improve the instruments for measuring radon exhalation rate.Keywords
This publication has 13 references indexed in Scilit:
- Development and application of a continuous measurement system for radon exhalation rateReview of Scientific Instruments, 2011
- Comparison of one- and two-filter detectors for atmospheric 222Rn measurements under various meteorological conditionsAtmospheric Measurement Techniques, 2010
- Radon exhalation from some finishing materials frequently used in SyriaRadiation Measurements, 2009
- Simultaneous 222Rn and 220Rn measurements in Winnipeg, CanadaRadiation Protection Dosimetry, 2009
- Simultaneous Measurements of Radon and Thoron Exhalation Rates and Comparison with Values Calculated by UNSCEAR EquationJournal of Radiation Research, 2009
- Radon exhalation rate from sand samples from the newly discovered high background radiation area at Erasama beach placer deposit of Orissa, IndiaRadiation Measurements, 2008
- Characteristics of radon and its progeny concentrations in air-conditioned office buildings in TokyoRadiation Protection Dosimetry, 2003
- Determination of radon exhalation rates from tiles using active and passive techniquesRadiation Measurements, 2001
- An Automatic Device for Measuring the Effect of Meteorological Factors on Radon-222 Flux from Soils on the Long TermRadiation Protection Dosimetry, 2001
- An International Intercomparison of Soil Gas Radon and Radon Exhalation MeasurementsHealth Physics, 1998