Yanliang Tan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yanliang Tan has a total of 117 co-authors. Here are the top co-authors by number of shared publications:
Hongzhi Yuan
33 shared publicationsRuomei Xie
26 shared publicationsZhongkai Fan
24 shared publicationsHaibo Yi
College of Physics and Electronic Engineering, Hengyang Normal University, Hengyang, Hunan Province, 421008, China
16 shared publicationsHuiying Li
College of Physics and Electronic Engineering, Hengyang Normal University, Hengyang, China
16 shared publicationsZhipeng Liu
16 shared publications
Latest Publications
- 18 November 2026
- Published by IOP Publishing in Physica Scripta
Utilizing LSTM networks for LaBr 3 :Ce scintillators RUL prediction under extreme gamma irradiations
Cerium-doped lanthanum bromide (LaBr ₃ :Ce) scintillation detectors are widely deployed in harsh radiation environments, such as space exploration, radioactive monitoring in nuclear facilities, and high energy physics. Cumulative radiation damage introduces lattice defects and radiation-induced absorption (RIA), which results in progressive degradation of optical transmittance and light yield. Previous investigations have been largely confined to post-irradiation characterizations of light output and transmittance. Therefore, predictive methods for estimating the remaining useful life (RUL) of LaBr ₃ :Ce scintillators remain absent, especially under extreme gamma irradiation. This paper presents a prognostic method based on multiphysics simulation, utilizing a Long Short-Term Memory (LSTM) network to estimate the RUL of LaBr ₃ :Ce crystals. A kinetic multiphysics platform is constructed to simulate the spatiotemporal evolution of radiation damage across multiple working conditions with varying source activities and crystal geometries, generating multi-condition EWLT sequences. A geometry-dependent optical threshold is then established to define the condition-specific failure state. A single LSTM network is trained jointly on the pooled sequences and compared with GRU, vanilla RNN, and exponential fitting methods under strict chronological splits. Results demonstrate that the LSTM achieves the lowest forecasting errors across the evaluated conditions, with group-mean RMSE values of 1.47×10 ⁻⁴ and 2.71×10 ⁻⁴ for the activity and geometry conditions, respectively. This method provides a data-driven approach for the predictive maintenance of radiation detectors.
- 18 November 2026
- Published by IOP Publishing in Physica Scripta
Utilizing LSTM networks for LaBr 3 :Ce scintillators RUL prediction under extreme gamma irradiations
Cerium-doped lanthanum bromide (LaBr ₃ :Ce) scintillation detectors are widely deployed in harsh radiation environments, such as space exploration, radioactive monitoring in nuclear facilities, and high energy physics. Cumulative radiation damage introduces lattice defects and radiation-induced absorption (RIA), which results in progressive degradation of optical transmittance and light yield. Previous investigations have been largely confined to post-irradiation characterizations of light output and transmittance. Therefore, predictive methods for estimating the remaining useful life (RUL) of LaBr ₃ :Ce scintillators remain absent, especially under extreme gamma irradiation. This paper presents a prognostic method based on multiphysics simulation, utilizing a Long Short-Term Memory (LSTM) network to estimate the RUL of LaBr ₃ :Ce crystals. A kinetic multiphysics platform is constructed to simulate the spatiotemporal evolution of radiation damage across multiple working conditions with varying source activities and crystal geometries, generating multi-condition EWLT sequences. A geometry-dependent optical threshold is then established to define the condition-specific failure state. A single LSTM network is trained jointly on the pooled sequences and compared with GRU, vanilla RNN, and exponential fitting methods under strict chronological splits. Results demonstrate that the LSTM achieves the lowest forecasting errors across the evaluated conditions, with group-mean RMSE values of 1.47×10 ⁻⁴ and 2.71×10 ⁻⁴ for the activity and geometry conditions, respectively. This method provides a data-driven approach for the predictive maintenance of radiation detectors.
- 6 November 2026
- Published by Elsevier in Measurement
- Vol. 294
Development of a low-pressure electrostatic collection radon monitor resistant to environmental temperature and humidity
- 6 November 2026
- Published by Elsevier in Measurement
- Vol. 294
Development of a low-pressure electrostatic collection radon monitor resistant to environmental temperature and humidity
- Open Access
- 7 October 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 59 (2)
Response characteristics and interference evaluation of RAD7 radon measurement within 50,000 ppm CO2 concentration threshold
- 7 October 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 59 (2)
Open AccessResponse characteristics and interference evaluation of RAD7 radon measurement within 50,000 ppm CO2 concentration threshold
- Open Access
Fault Diagnosis of Semiconductor Detectors Using a Radial Basis Function Neural Network with Bayesian Optimization and K-Means Clustering
This study evaluates radial basis function neural networks (RBFNNs) for severity classification within predefined semiconductor-detector fault categories. The datasets contain simulated PN aging, RC circuit faults and radiation damage, together with three hybrid-fault constructions. Raw waveforms were partitioned before fitting feature transformations. A four-variant ablation over ten stratified partitions assessed Bayesian optimization (BO) of the hidden-layer size and radial basis width, and K-means placement of the centers. With training-fitted principal component analysis (PCA), the combined model achieved mean test accuracies of 97.67 ± 1.97% for PN aging and 100.00 ± 0.00% for RC faults, but only 7.78 ± 1.40% for the 66-class radiation task. An exploratory radiation reassessment using pulse-amplitude and residual-noise features, with a distance-scaled RBF width, achieved 72.42 ± 1.57% accuracy and 72.26 ± 1.63% macro-F1 over three partitions. Three frozen radiation models achieved a mean accuracy of 71.83% on 66,000 newly generated waveforms. Three PN aging–RC partitions gave 86.40 ± 1.52% accuracy within the standard search range. A separately selected expanded-range model achieved 96.33% on 110,000 new simulated waveforms. And three PN aging–radiation damage and RC–radiation damage partitions gave 77.40 ± 1.38% and 78.45 ± 1.28% accuracy with the standard search range, respectively.
Open AccessFault Diagnosis of Semiconductor Detectors Using a Radial Basis Function Neural Network with Bayesian Optimization and K-Means Clustering
This study evaluates radial basis function neural networks (RBFNNs) for severity classification within predefined semiconductor-detector fault categories. The datasets contain simulated PN aging, RC circuit faults and radiation damage, together with three hybrid-fault constructions. Raw waveforms were partitioned before fitting feature transformations. A four-variant ablation over ten stratified partitions assessed Bayesian optimization (BO) of the hidden-layer size and radial basis width, and K-means placement of the centers. With training-fitted principal component analysis (PCA), the combined model achieved mean test accuracies of 97.67 ± 1.97% for PN aging and 100.00 ± 0.00% for RC faults, but only 7.78 ± 1.40% for the 66-class radiation task. An exploratory radiation reassessment using pulse-amplitude and residual-noise features, with a distance-scaled RBF width, achieved 72.42 ± 1.57% accuracy and 72.26 ± 1.63% macro-F1 over three partitions. Three frozen radiation models achieved a mean accuracy of 71.83% on 66,000 newly generated waveforms. Three PN aging–RC partitions gave 86.40 ± 1.52% accuracy within the standard search range. A separately selected expanded-range model achieved 96.33% on 110,000 new simulated waveforms. And three PN aging–radiation damage and RC–radiation damage partitions gave 77.40 ± 1.38% and 78.45 ± 1.28% accuracy with the standard search range, respectively.
- 22 September 2026
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 238, 112952
Nafion tube-based technology for extending desiccant longevity in RAD7 radon monitors
- 22 September 2026
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 238, 112952
Nafion tube-based technology for extending desiccant longevity in RAD7 radon monitors
- 15 September 2026
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 238
Radon release characteristics of autunite under coupled environmental temperature and humidity conditions
- 15 September 2026
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 238
Radon release characteristics of autunite under coupled environmental temperature and humidity conditions
- 8 September 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (36) , 365003
Development of a static chamber system based on magnetic triggering mechanism for precise measurement of activated carbon radon adsorption rate
Accurately assessing the passive radon adsorption performance of porous materials under natural conditions is of vital importance for environmental radiation protection. Currently, the existing testing methods have obvious limitations: the active adsorption method is affected by forced airflow and it is difficult to extract the true physical adsorption parameters; while the traditional static chamber method faces the dual problems of gas mixture delay and mechanical operation interference. To address the aforementioned bottlenecks, this paper proposes a dual-cycle closed radon monitoring system based on a magnetic triggering mechanism. By placing the sample box with a magnetic control cover in the chamber in advance, the passive adsorption process of the dried coconut shell activated carbon can be triggered instantly without damaging the system’s sealing boundary. The experiment was conducted in two stages: Firstly, the baseline leakage rate of the system was calibrated by monitoring the decay of natural radon. Then, the adsorption process was remotely initiated by a magnetic trigger, and the entire process did not disrupt the sealed state. The full-time concentration data were nonlinearly fitted using a first-order kinetic model that included leakage and adsorption terms, resulting in an average natural leakage rate of (1.19 ± 0.09) × 10 −5 s −1 and a passive radon adsorption rate constant of (3.61 ± 0.20) × 10 −4 s −1 (dry coconut shell activated carbon). The entire adsorption process was driven solely by the natural concentration gradient, and the samples could be pre-stored in sealed containers for a long time before the test. Crucially, the measured adsorption rate is approximately 30 times greater than the baseline leakage, demonstrating the system’s ability to effectively decouple genuine adsorption kinetics from background errors. This low-disturbance paradigm enables reliable evaluation of porous materials for practical indoor radon mitigation.
- 8 September 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (36) , 365003
Development of a static chamber system based on magnetic triggering mechanism for precise measurement of activated carbon radon adsorption rate
Accurately assessing the passive radon adsorption performance of porous materials under natural conditions is of vital importance for environmental radiation protection. Currently, the existing testing methods have obvious limitations: the active adsorption method is affected by forced airflow and it is difficult to extract the true physical adsorption parameters; while the traditional static chamber method faces the dual problems of gas mixture delay and mechanical operation interference. To address the aforementioned bottlenecks, this paper proposes a dual-cycle closed radon monitoring system based on a magnetic triggering mechanism. By placing the sample box with a magnetic control cover in the chamber in advance, the passive adsorption process of the dried coconut shell activated carbon can be triggered instantly without damaging the system’s sealing boundary. The experiment was conducted in two stages: Firstly, the baseline leakage rate of the system was calibrated by monitoring the decay of natural radon. Then, the adsorption process was remotely initiated by a magnetic trigger, and the entire process did not disrupt the sealed state. The full-time concentration data were nonlinearly fitted using a first-order kinetic model that included leakage and adsorption terms, resulting in an average natural leakage rate of (1.19 ± 0.09) × 10 −5 s −1 and a passive radon adsorption rate constant of (3.61 ± 0.20) × 10 −4 s −1 (dry coconut shell activated carbon). The entire adsorption process was driven solely by the natural concentration gradient, and the samples could be pre-stored in sealed containers for a long time before the test. Crucially, the measured adsorption rate is approximately 30 times greater than the baseline leakage, demonstrating the system’s ability to effectively decouple genuine adsorption kinetics from background errors. This low-disturbance paradigm enables reliable evaluation of porous materials for practical indoor radon mitigation.
- 30 August 2026
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 238
Experimental study on the effect of environmental parameters on Rn-220 exhalation rate
- 30 August 2026
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 238
Experimental study on the effect of environmental parameters on Rn-220 exhalation rate
- 14 August 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (33) , 336002
Rapid transient characterization of local formaldehyde and TVOC release from indoor surfaces using a detector-based dynamic concentration model
Formaldehyde and total volatile organic compounds (TVOCs) are major indoor air pollutants that can negatively impact both indoor air quality and human health. Their primary sources are emissions from the surfaces of building and decorative materials. Conventional environmental chamber methods are generally complex and time-consuming, which limits their applicability for rapid on-site measurements. In this study, a cover-based transient measurement method was developed using a small stainless-steel cover, portable formaldehyde and TVOC detectors, and a dynamic concentration model. Three existing indoor surfaces, including a meeting-room cabinet, a meeting-room floor, and a study-room desktop, were monitored for 20 min under field conditions. Based on Fick’s law and a transient mass balance incorporating the combined effects of leakage and sink adsorption, the measured concentration responses were fitted to derive a local area-specific release parameter E 0 and an effective influence coefficient k e . The model reasonably reproduced the measured concentration curves, with R 2 values exceeding 0.88 for all datasets. Repeated measurements generally showed consistent normalized transient response patterns and two-dimensional SSE analysis identified a principal numerical optimum for the fitted parameters while revealing appreciable correlation between the E 0 and k e . These results indicate that the proposed method provides a practical basis for rapid comparative screening of short-term local release behavior from indoor surfaces under field conditions.
- 14 August 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (33) , 336002
Rapid transient characterization of local formaldehyde and TVOC release from indoor surfaces using a detector-based dynamic concentration model
Formaldehyde and total volatile organic compounds (TVOCs) are major indoor air pollutants that can negatively impact both indoor air quality and human health. Their primary sources are emissions from the surfaces of building and decorative materials. Conventional environmental chamber methods are generally complex and time-consuming, which limits their applicability for rapid on-site measurements. In this study, a cover-based transient measurement method was developed using a small stainless-steel cover, portable formaldehyde and TVOC detectors, and a dynamic concentration model. Three existing indoor surfaces, including a meeting-room cabinet, a meeting-room floor, and a study-room desktop, were monitored for 20 min under field conditions. Based on Fick’s law and a transient mass balance incorporating the combined effects of leakage and sink adsorption, the measured concentration responses were fitted to derive a local area-specific release parameter E 0 and an effective influence coefficient k e . The model reasonably reproduced the measured concentration curves, with R 2 values exceeding 0.88 for all datasets. Repeated measurements generally showed consistent normalized transient response patterns and two-dimensional SSE analysis identified a principal numerical optimum for the fitted parameters while revealing appreciable correlation between the E 0 and k e . These results indicate that the proposed method provides a practical basis for rapid comparative screening of short-term local release behavior from indoor surfaces under field conditions.
- 18 June 2026
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 37 (9)
Classification of vibration and ionization signals in pulsed ionization chambers based on a temporal convolutional network
- 18 June 2026
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 37 (9)
Classification of vibration and ionization signals in pulsed ionization chambers based on a temporal convolutional network