Smartphone camera oximetry in an induced hypoxemia study
Open Access
- 19 September 2022
- journal article
- research article
- Published by Springer Nature in npj Digital Medicine
- Vol. 5 (1) , 1-10
Abstract
Hypoxemia, a medical condition that occurs when the blood is not carrying enough oxygen to adequately supply the tissues, is a leading indicator for dangerous complications of respiratory diseases like asthma, COPD, and COVID-19. While purpose-built pulse oximeters can provide accurate blood-oxygen saturation (SpO2) readings that allow for diagnosis of hypoxemia, enabling this capability in unmodified smartphone cameras via a software update could give more people access to important information about their health. Towards this goal, we performed the first clinical development validation on a smartphone camera-based SpO2 sensing system using a varied fraction of inspired oxygen (FiO2) protocol, creating a clinically relevant validation dataset for solely smartphone-based contact PPG methods on a wider range of SpO2 values (70–100%) than prior studies (85–100%). We built a deep learning model using this data to demonstrate an overall MAE = 5.00% SpO2 while identifying positive cases of low SpO2 < 90% with 81% sensitivity and 79% specificity. We also provide the data in open-source format, so that others may build on this work.Keywords
All Related Versions
This publication has 45 references indexed in Scilit:
- A smartphone dongle for diagnosis of infectious diseases at the point of careScience Translational Medicine, 2015
- Diagnosis and treatment of diabetic ketoacidosisEmergency Nurse, 2012
- Usability testing of a prototype Phone Oximeter with healthcare providers in high‐ and low‐medical resource environments*Anaesthesia, 2012
- Cuffless Differential Blood Pressure Estimation Using Smart PhonesIEEE Transactions on Biomedical Engineering, 2012
- Accuracy and reliability of pulse oximetry at different arterial carbon dioxide pressure levelsEuropean Respiratory Journal, 2008
- Dark Skin Decreases the Accuracy of Pulse Oximeters at Low Oxygen Saturation: The Effects of Oximeter Probe Type and GenderAnesthesia & Analgesia, 2007
- Maximizing the Laboratory Setting for Testing Devices and Understanding Statistical Output in Pulse OximetryAnesthesia & Analgesia, 2007
- Prediction of pulmonary hypertension in idiopathic pulmonary fibrosisRespiratory Medicine, 2007
- The feasibility and usefulness of oximetry measurements in primary carePrimary Care Respiratory Journal, 2003
- How accurate are pulse oximeters in patients with acute exacerbations of chronic obstructive airways disease?Respiratory Medicine, 2001