Unbiased and reproducible liver MRI-PDFF estimation using a scan protocol-informed deep learning method
Authors:
- 5 November 2024
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 35 (5) , 2843-2854
Abstract
Objective To estimate proton density fat fraction (PDFF) from chemical shift encoded (CSE) MR images using a deep learning (DL)-based method that is precise and robust to different MR scanners and acquisition echo times (TEs). Methods Variable echo times neural network (VET-Net) is a two-stage framework that first estimates nonlinear variables of the CSE-MR signal model, to posteriorly estimate water/fat signal components using the least-squares method. VET-Net incorporates a vector with TEs as an auxiliary input, therefore enabling PDFF calculation with any TE setting. A single-site liver CSE-MRI dataset (188 subjects, 4146 axial slices) was considered, which was split into training (150 subjects), validation (18), and testing (20) subsets. Testing subjects were scanned using several protocols with different TEs, which we then used to measure the PDFF reproducibility coefficient (RDC) at two regions of interest (ROIs): the right posterior and left hepatic lobes. An open-source multi-site and multi-vendor fat–water phantom dataset was also used for PDFF bias assessment. Results VET-Net showed RDCs of 1.71% and 1.04% on the right posterior and left hepatic lobes, respectively, across different TEs, which was comparable to a reference graph cuts-based method (RDCs = 1.71% and 0.86%). VET-Net also showed a smaller PDFF bias (−0.55%) than graph cuts (0.93%) when tested on a multi-site phantom dataset. Reproducibility (1.94% and 1.59%) and bias (−2.04%) were negatively affected when the auxiliary TE input was not considered. Conclusion VET-Net provided unbiased and precise PDFF estimations using CSE-MR images from different hardware vendors and different TEs, outperforming conventional DL approaches. Key Points Question Reproducibility of liver PDFF DL-based approaches on different scan protocols or manufacturers is not validated. Findings VET-Net showed a PDFF bias of −0.55% on a multi-site phantom dataset, and RDCs of 1.71% and 1.04% at two liver ROIs. Clinical relevance VET-Net provides efficient, in terms of scan and processing times, and unbiased PDFF estimations across different MR scanners and scan protocols, and therefore it can be leveraged to expand the use of MRI-based liver fat quantification to assess hepatic steatosis.Keywords
Funding Information
- Agencia Nacional de Investigación y Desarrollo (ICN2021_004, DOCTORADO BECAS CHILE/2020 – 21210665, Fondecyt 1220922, Fondecyt 1231535)
This publication has 26 references indexed in Scilit:
- Robust water–fat separation based on deep learning model exploring multi‐echo nature of mGREMagnetic Resonance in Medicine, 2020
- Deep neural network for water/fat separation: Supervised training, unsupervised training, and no trainingMagnetic Resonance in Medicine, 2020
- Separation of water and fat signal in whole‐body gradient echo scans using convolutional neural networksMagnetic Resonance in Medicine, 2019
- Robust water–fat separation for multi‐echo gradient‐recalled echo sequence using convolutional neural networkMagnetic Resonance in Medicine, 2019
- Water–fat separation and parameter mapping in cardiac MRI via deep learning with a convolutional neural networkJournal of Magnetic Resonance Imaging, 2019
- Assessment of the generalization of learned image reconstruction and the potential for transfer learningMagnetic Resonance in Medicine, 2018
- Multisite, multivendor validation of the accuracy and reproducibility of proton-density fat-fraction quantification at 1.5T and 3T using a fat-water phantomMagnetic Resonance in Medicine, 2016
- Robust water/fat separation in the presence of large field inhomogeneities using a graph cut algorithmMagnetic Resonance in Medicine, 2009
- Multiecho reconstruction for simultaneous water‐fat decomposition and T2* estimationJournal of Magnetic Resonance Imaging, 2007
- Cramér–Rao bounds for three‐point decomposition of water and fatMagnetic Resonance in Medicine, 2005