Mechanical and structural properties of human aortic and pulmonary allografts do not deteriorate in the first 10 years of cryopreservation and storage in nitrogen
- 22 March 2019
- journal article
- research article
- Published by Springer Nature in Cell and Tissue Banking
- Vol. 20 (2) , 221-241
Abstract
The aortic and pulmonary allograft heart valves (AHV) are used in the cardiac surgery for replacing the impaired semilunar valves. They are harvested from donor hearts and cryostored in tissue banks. The expiration period was set to 5 years arbitrarily. We hypothesized that their mechanical and structural properties do not deteriorate after this period. A total of 64 human AHV (31 aortic and 33 pulmonary) of different length of cryopreservation (fresh, 0–5, 5–10, over 10 years) were sampled to different tissue strips (artery, leaflet, ventriculo-arterial junction) and tested by tensile test with loading velocity 10 mm/min until tissue rupture. Neighbouring regions of tissue were processed histologically and evaluated for elastin and collagen area fraction. The results were evaluated statistically. In aortic AHV, the physical deformation response of wall samples to stress did not changed significantly neither during the process of cryopreservation nor during the first 10 years of storage. In pulmonary AHV, the ultimate strain dropped after 5 years of cryopreservation indicating that pulmonary artery was significantly less deformable at the time of rupture. On the other hand, the ultimate stress was equal during the first 10 years of cryostorage. The changes in collagen and elastin amount in the tissue samples were not associated with mechanical impairment. Neither elasticity, stiffness and solidity nor morphology of aortic and pulmonary AHV did not change reasonably with cryopreservation and in the first 10 years of cryostorage. This evidence suggests that the expiration period might be extended in the future.Keywords
Funding Information
- Ministerstvo Školství, Mládeže a Tělovýchovy (CZ.02.1.01/0.0/0.0/17_048/0007280, LO1506, LO1503)
- Univerzita Karlova v Praze (Progres Q39)
This publication has 36 references indexed in Scilit:
- Is allograft aortic valve replacement still an option? When, which, where?The Journal of Thoracic and Cardiovascular Surgery, 2018
- Performance of SynerGraft Decellularized Pulmonary Allografts Compared With Standard Cryopreserved Allografts: Results From Multiinstitutional DataThe Annals of Thoracic Surgery, 2017
- Interlayer micromechanics of the aortic heart valve leafletBiomechanics and Modeling in Mechanobiology, 2013
- What tissue bankers should know about the use of allograft heart valvesCell and Tissue Banking, 2009
- Cryopreserved Semilunar Heart Valve Allografts: Leaflet Surface Damage in Scanning Electron MicroscopyZentralblatt fur Chirurgie, 2008
- Allograft Tissue for Use in Valve ReplacementCell and Tissue Banking, 2006
- Mechanical Characteristics of Fresh and Frozen Human Descending Thoracic AortaJournal of Surgical Research, 1996
- Age-Related Collagen and Elastin Content of Human Heart ValvesJournal of Gerontology, 1967
- Homograft Aortic Valve Replacement in Aortic Incompetence and StenosisThorax, 1964
- A METHOD FOR PLACING A TOTAL HOMOLOGOUS AORTIC VALVE IN THE SUBCORONARY POSITIONThe Lancet, 1962