Jaroslav Spatenka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Jaroslav Spatenka has a total of 264 co-authors. Here are the top co-authors by number of shared publications:
B Hucín
14 shared publicationsT Honĕk
12 shared publicationsB Fiser
8 shared publicationsS Tůma
Kardiocentrum FNsP, Praha-Motol
7 shared publicationsJan Burkert
Transplant Center, University Hospital Motol, Prague, Czech Republic
6 shared publicationsJ Janda
5 shared publications
Latest Publications
- Open Access
- 21 April 2023
- Published by Springer Nature in Cell and Tissue Banking
- Vol. 25 (1) , 87-98
Clinical experience of reoperative right ventricular outflow tract reconstruction with valved conduits: risk factors for conduit failure in long-term follow-up
Reconstruction of right ventricular outflow tract in patients with congenital heart disease in various age groups remains a controversial issue. Currently, a little is known about the fate of secondary and subsequent conduit. The aim of the study was to determine risk factors of conduit failure, evaluate long-term conduit survival, find out which type of conduit should be preferred in case of reoperations. We performed a retrospective analysis of a total of 249 records of valved conduit secondary and subsequent replacement in right ventricular outflow tract in 197 patients. Median follow-up was 5.7 years. The study endpoints were defined as conduit explants; balloon dilatation of the graft (excluding balloon dilatation of left/right pulmonary artery), transcatheter pulmonary valve implantation; heart transplantation or death of the patient. There were total of 21 deaths (11% mortality) among 197 patients during the follow-up, 2 patients underwent heart transplant, in 23 implanted conduits pulmonary angioplasty or/including transcatheter pulmonary valve implantation was afterwards performed due to graft failure, conduit had to be explanted in 46 cases. After 28 years follow-up, freedom from graft failure after 5 years was 77%, 48% after 10 years and 21% after 15 years. Reoperative right ventricular outflow tract reconstruction demonstrates good mid-term and acceptable long-term outcomes regardless of the type of conduit implanted. Worse long-term graft survival of secondary and further conduits is associated with younger age of the recipient at implantation, small size of the conduit, younger age of donor and male donor in case of allograft implantation.
- 21 April 2023
- Published by Springer Nature in Cell and Tissue Banking
- Vol. 25 (1) , 87-98
Open AccessClinical experience of reoperative right ventricular outflow tract reconstruction with valved conduits: risk factors for conduit failure in long-term follow-up
Reconstruction of right ventricular outflow tract in patients with congenital heart disease in various age groups remains a controversial issue. Currently, a little is known about the fate of secondary and subsequent conduit. The aim of the study was to determine risk factors of conduit failure, evaluate long-term conduit survival, find out which type of conduit should be preferred in case of reoperations. We performed a retrospective analysis of a total of 249 records of valved conduit secondary and subsequent replacement in right ventricular outflow tract in 197 patients. Median follow-up was 5.7 years. The study endpoints were defined as conduit explants; balloon dilatation of the graft (excluding balloon dilatation of left/right pulmonary artery), transcatheter pulmonary valve implantation; heart transplantation or death of the patient. There were total of 21 deaths (11% mortality) among 197 patients during the follow-up, 2 patients underwent heart transplant, in 23 implanted conduits pulmonary angioplasty or/including transcatheter pulmonary valve implantation was afterwards performed due to graft failure, conduit had to be explanted in 46 cases. After 28 years follow-up, freedom from graft failure after 5 years was 77%, 48% after 10 years and 21% after 15 years. Reoperative right ventricular outflow tract reconstruction demonstrates good mid-term and acceptable long-term outcomes regardless of the type of conduit implanted. Worse long-term graft survival of secondary and further conduits is associated with younger age of the recipient at implantation, small size of the conduit, younger age of donor and male donor in case of allograft implantation.
- 24 June 2020
- Published by Springer Nature in Cell and Tissue Banking
- Vol. 22 (2) , 161-184
The time has come to extend the expiration limit of cryopreserved allograft heart valves
Despite the wide choice of commercial heart valve prostheses, cryopreserved semilunar allograft heart valves (C-AHV) are required, and successfully transplanted in selected groups of patients. The expiration limit (EL) criteria have not been defined yet. Most Tissue Establishments (TE) use the EL of 5 years. From physiological, functional, and surgical point of view, the morphology and mechanical properties of aortic and pulmonary roots represent basic features limiting the EL of C-AHV. The aim of this work was to review methods of AHV tissue structural analysis and mechanical testing from the perspective of suitability for EL validation studies. Microscopic structure analysis of great arterial wall and semilunar leaflets tissue should clearly demonstrate cells as well as the extracellular matrix components by highly reproducible and specific histological staining procedures. Quantitative morphometry using stereological grids has proved to be effective, as the exact statistics was feasible. From mechanical testing methods, tensile test was the most suitable. Young’s moduli of elasticity, ultimate stress and strain were shown to represent most important AHV tissue mechanical characteristics, suitable for exact statistical analysis. C-AHV are prepared by many different protocols, so as each TE has to work out own EL for C-AHV.
- 24 June 2020
- Published by Springer Nature in Cell and Tissue Banking
- Vol. 22 (2) , 161-184
The time has come to extend the expiration limit of cryopreserved allograft heart valves
Despite the wide choice of commercial heart valve prostheses, cryopreserved semilunar allograft heart valves (C-AHV) are required, and successfully transplanted in selected groups of patients. The expiration limit (EL) criteria have not been defined yet. Most Tissue Establishments (TE) use the EL of 5 years. From physiological, functional, and surgical point of view, the morphology and mechanical properties of aortic and pulmonary roots represent basic features limiting the EL of C-AHV. The aim of this work was to review methods of AHV tissue structural analysis and mechanical testing from the perspective of suitability for EL validation studies. Microscopic structure analysis of great arterial wall and semilunar leaflets tissue should clearly demonstrate cells as well as the extracellular matrix components by highly reproducible and specific histological staining procedures. Quantitative morphometry using stereological grids has proved to be effective, as the exact statistics was feasible. From mechanical testing methods, tensile test was the most suitable. Young’s moduli of elasticity, ultimate stress and strain were shown to represent most important AHV tissue mechanical characteristics, suitable for exact statistical analysis. C-AHV are prepared by many different protocols, so as each TE has to work out own EL for C-AHV.
- 22 March 2019
- Published by Springer Nature in Cell and Tissue Banking
- Vol. 20 (2) , 221-241
Mechanical and structural properties of human aortic and pulmonary allografts do not deteriorate in the first 10 years of cryopreservation and storage in nitrogen
The aortic and pulmonary allograft heart valves (AHV) are used in the cardiac surgery for replacing the impaired semilunar valves. They are harvested from donor hearts and cryostored in tissue banks. The expiration period was set to 5 years arbitrarily. We hypothesized that their mechanical and structural properties do not deteriorate after this period. A total of 64 human AHV (31 aortic and 33 pulmonary) of different length of cryopreservation (fresh, 0–5, 5–10, over 10 years) were sampled to different tissue strips (artery, leaflet, ventriculo-arterial junction) and tested by tensile test with loading velocity 10 mm/min until tissue rupture. Neighbouring regions of tissue were processed histologically and evaluated for elastin and collagen area fraction. The results were evaluated statistically. In aortic AHV, the physical deformation response of wall samples to stress did not changed significantly neither during the process of cryopreservation nor during the first 10 years of storage. In pulmonary AHV, the ultimate strain dropped after 5 years of cryopreservation indicating that pulmonary artery was significantly less deformable at the time of rupture. On the other hand, the ultimate stress was equal during the first 10 years of cryostorage. The changes in collagen and elastin amount in the tissue samples were not associated with mechanical impairment. Neither elasticity, stiffness and solidity nor morphology of aortic and pulmonary AHV did not change reasonably with cryopreservation and in the first 10 years of cryostorage. This evidence suggests that the expiration period might be extended in the future.
- 22 March 2019
- Published by Springer Nature in Cell and Tissue Banking
- Vol. 20 (2) , 221-241
Mechanical and structural properties of human aortic and pulmonary allografts do not deteriorate in the first 10 years of cryopreservation and storage in nitrogen
The aortic and pulmonary allograft heart valves (AHV) are used in the cardiac surgery for replacing the impaired semilunar valves. They are harvested from donor hearts and cryostored in tissue banks. The expiration period was set to 5 years arbitrarily. We hypothesized that their mechanical and structural properties do not deteriorate after this period. A total of 64 human AHV (31 aortic and 33 pulmonary) of different length of cryopreservation (fresh, 0–5, 5–10, over 10 years) were sampled to different tissue strips (artery, leaflet, ventriculo-arterial junction) and tested by tensile test with loading velocity 10 mm/min until tissue rupture. Neighbouring regions of tissue were processed histologically and evaluated for elastin and collagen area fraction. The results were evaluated statistically. In aortic AHV, the physical deformation response of wall samples to stress did not changed significantly neither during the process of cryopreservation nor during the first 10 years of storage. In pulmonary AHV, the ultimate strain dropped after 5 years of cryopreservation indicating that pulmonary artery was significantly less deformable at the time of rupture. On the other hand, the ultimate stress was equal during the first 10 years of cryostorage. The changes in collagen and elastin amount in the tissue samples were not associated with mechanical impairment. Neither elasticity, stiffness and solidity nor morphology of aortic and pulmonary AHV did not change reasonably with cryopreservation and in the first 10 years of cryostorage. This evidence suggests that the expiration period might be extended in the future.
- Open Access
- 31 August 2018
- Published by Wroclaw Medical University in Advances in Clinical and Experimental Medicine
- Vol. 27 (8) , 1033-1036
Structural changes arising from different thawing protocols on cryopreserved human allograft’s aortic valve leaflets
Background. The aim of our experimental work was to assess the impact and morphological changes that arise during different thawing protocols on human aortic valve (AV) leaflets resected from cryopreserved aortic root allog rafts (CARAs). Objectives. Two thawing protocols were tested: 1. CARAs were thawed at a room temperature (23 degrees C); 2. CARAs were placed directly into a water bath at a temperature of 37 degrees C. After all the samples were thawed, non-coronary AV leaflets were sampled from each specimen and fixed in a 4% formaldehyde solution before they were sent for morphological analysis. Material and methods. All the samples were washed in distilled water for 5 min and dehydrated in a graded ethanol series (70%, 85%, 95%, and 100%) for 5 min at each level. The tissue samples were then immersed in 100% hexamethyldisilazane (HMDS) for 10 min, and then air-dried in an exhaust hood at room temperature. Processed samples were mounted on stainless steel stubs and coated with gold. Histological analysis was performed with the use of an electron microscope on a scanning mode operating at 25 kV - BS 301. Results. Thawing protocol 1 (room temperature at 23 degrees C): 6 (100%) samples showed loss of the endothelial covering of the basal membrane with no damage to the basal lamina. Thawing protocol 2 (water bath at 37 degrees C): 5 (83%) samples showed loss of the endothelial covering of the basal membrane with no damage to the basal lamina. One (17%) sample showed loss of the endothelial covering the basal membrane with significant damage to the basal membrane. Conclusions. Based on our experimental work, we can clearly conclude that cryopreserved AV leaflet allografts show identical structural changes at different rates of thawing.
- 31 August 2018
- Published by Wroclaw Medical University in Advances in Clinical and Experimental Medicine
- Vol. 27 (8) , 1033-1036
Open AccessStructural changes arising from different thawing protocols on cryopreserved human allograft’s aortic valve leaflets
Background. The aim of our experimental work was to assess the impact and morphological changes that arise during different thawing protocols on human aortic valve (AV) leaflets resected from cryopreserved aortic root allog rafts (CARAs). Objectives. Two thawing protocols were tested: 1. CARAs were thawed at a room temperature (23 degrees C); 2. CARAs were placed directly into a water bath at a temperature of 37 degrees C. After all the samples were thawed, non-coronary AV leaflets were sampled from each specimen and fixed in a 4% formaldehyde solution before they were sent for morphological analysis. Material and methods. All the samples were washed in distilled water for 5 min and dehydrated in a graded ethanol series (70%, 85%, 95%, and 100%) for 5 min at each level. The tissue samples were then immersed in 100% hexamethyldisilazane (HMDS) for 10 min, and then air-dried in an exhaust hood at room temperature. Processed samples were mounted on stainless steel stubs and coated with gold. Histological analysis was performed with the use of an electron microscope on a scanning mode operating at 25 kV - BS 301. Results. Thawing protocol 1 (room temperature at 23 degrees C): 6 (100%) samples showed loss of the endothelial covering of the basal membrane with no damage to the basal lamina. Thawing protocol 2 (water bath at 37 degrees C): 5 (83%) samples showed loss of the endothelial covering of the basal membrane with no damage to the basal lamina. One (17%) sample showed loss of the endothelial covering the basal membrane with significant damage to the basal membrane. Conclusions. Based on our experimental work, we can clearly conclude that cryopreserved AV leaflet allografts show identical structural changes at different rates of thawing.
- 3 March 2018
- Published by Springer Nature in Cell and Tissue Banking
- Vol. 19 (3) , 437-445
Organization model for allotransplantations of cryopreserved vascular grafts in Czech Republic
The transplantation of fresh or cryopreserved vascular allografts in patients with a prosthetic graft infection or critical limb ischemia is necessary for their limb salvage and, in many cases, represents a lifesaving procedure. While transplantation of fresh allografts has a long history in the Czech Republic, the standard use of cryopreserved vascular allografts was introduced into the clinical practice in 2011 as a result of the implementation of EU Directive 2004/23/EC into national legislation (Human Cell and Tissue Act No. 296/2008 Coll.). The authors present an organizational model based on cooperation between the majority of Czech Transplant Centers with a tissue establishment licensed by the national competent authority. In various points, we are addressing individual aspects of experimental and clinical studies which affect clinical practice. Based on experimental and clinical work, the first validation of cryopreserved arterial and venous grafts for clinical use was performed between 2011 and 2013. The growing number of centers participating in this programme led to a growing number of patients who underwent transplantation of vascular allografts. In 2015 the numbers of transplanted fresh versus cryopreserved allografts in the Czech Republic were almost equal. Cooperation of the participating centers in the Czech Republic with the licensed Tissue Establishment made it possible to achieve a full compliance with the European Union Directives, and harmonized national legal norms and assured a high quality of cryopreserved vascular allografts.
- 3 March 2018
- Published by Springer Nature in Cell and Tissue Banking
- Vol. 19 (3) , 437-445
Organization model for allotransplantations of cryopreserved vascular grafts in Czech Republic
The transplantation of fresh or cryopreserved vascular allografts in patients with a prosthetic graft infection or critical limb ischemia is necessary for their limb salvage and, in many cases, represents a lifesaving procedure. While transplantation of fresh allografts has a long history in the Czech Republic, the standard use of cryopreserved vascular allografts was introduced into the clinical practice in 2011 as a result of the implementation of EU Directive 2004/23/EC into national legislation (Human Cell and Tissue Act No. 296/2008 Coll.). The authors present an organizational model based on cooperation between the majority of Czech Transplant Centers with a tissue establishment licensed by the national competent authority. In various points, we are addressing individual aspects of experimental and clinical studies which affect clinical practice. Based on experimental and clinical work, the first validation of cryopreserved arterial and venous grafts for clinical use was performed between 2011 and 2013. The growing number of centers participating in this programme led to a growing number of patients who underwent transplantation of vascular allografts. In 2015 the numbers of transplanted fresh versus cryopreserved allografts in the Czech Republic were almost equal. Cooperation of the participating centers in the Czech Republic with the licensed Tissue Establishment made it possible to achieve a full compliance with the European Union Directives, and harmonized national legal norms and assured a high quality of cryopreserved vascular allografts.
- 1 July 2017
- Published by Elsevier in Annals of Anatomy - Anatomischer Anzeiger
- Vol. 212, 17-26
The composition and biomechanical properties of human cryopreserved aortas, pulmonary trunks, and aortic and pulmonary cusps
- 1 July 2017
- Published by Elsevier in Annals of Anatomy - Anatomischer Anzeiger
- Vol. 212, 17-26
The composition and biomechanical properties of human cryopreserved aortas, pulmonary trunks, and aortic and pulmonary cusps
- Open Access
- 17 April 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (4) , e0175007
Cryopreserved human aortic root allografts arterial wall: Structural changes occurring during thawing
The aim of our experimental work was to assess morphological changes of arterial wall that arise during different thawing protocols of a cryopreserved human aortic root allograft (CHARA) arterial wall. The experiment was performed on CHARAs. Two thawing protocols were tested: 1, CHARAs were thawed at a room temperature at +23°C; 2, CHARAs were placed directly into a water bath at +37°C. After fixation, all samples were washed in distilled water for 5 min, and dehydrated in a graded ethanol series (70, 85, 95, and 100%) for 5 min at each level. The tissue samples were then immersed in 100% hexamethyldisilazane for 10 minutes and air dried in an exhaust hood at room temperature. Processed samples were mounted on stainless steel stubs, coated with gold. Thawing protocol 1: All 6 (100%) samples showed loss of the endothelium and damage to the subendothelial layers with randomly dispersed circular defects and micro-fractures without smooth muscle cells contractions in the tunica media. Thawing protocol 2: All 6 (100%) samples showed loss of endothelium from the luminal surface, longitudinal corrugations in the direction of blood flow caused by smooth muscle cells contractions in the tunica media with frequent fractures in the subendothelial layer All the samples thawed at the room temperature showed smaller structural damage to the CHARA arterial wall with no smooth muscle cell contraction in tunica media when compared to the samples thawed in a water bath.
- 17 April 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (4) , e0175007
Open AccessCryopreserved human aortic root allografts arterial wall: Structural changes occurring during thawing
The aim of our experimental work was to assess morphological changes of arterial wall that arise during different thawing protocols of a cryopreserved human aortic root allograft (CHARA) arterial wall. The experiment was performed on CHARAs. Two thawing protocols were tested: 1, CHARAs were thawed at a room temperature at +23°C; 2, CHARAs were placed directly into a water bath at +37°C. After fixation, all samples were washed in distilled water for 5 min, and dehydrated in a graded ethanol series (70, 85, 95, and 100%) for 5 min at each level. The tissue samples were then immersed in 100% hexamethyldisilazane for 10 minutes and air dried in an exhaust hood at room temperature. Processed samples were mounted on stainless steel stubs, coated with gold. Thawing protocol 1: All 6 (100%) samples showed loss of the endothelium and damage to the subendothelial layers with randomly dispersed circular defects and micro-fractures without smooth muscle cells contractions in the tunica media. Thawing protocol 2: All 6 (100%) samples showed loss of endothelium from the luminal surface, longitudinal corrugations in the direction of blood flow caused by smooth muscle cells contractions in the tunica media with frequent fractures in the subendothelial layer All the samples thawed at the room temperature showed smaller structural damage to the CHARA arterial wall with no smooth muscle cell contraction in tunica media when compared to the samples thawed in a water bath.
- Open Access
- 19 September 2016
- Published by Oxford University Press (OUP) in European Journal of Heart Failure
- Vol. 19 (4) , 522-530
Myocardial Iron Content and Mitochondrial Function in Human Heart Failure: A Direct Tissue Analysis
Aims Iron replacement improves clinical status in iron‐deficient patients with heart failure (HF), but the pathophysiology is poorly understood. Iron is essential not only for erythropoiesis, but also for cellular bioenergetics. The impact of myocardial iron deficiency (MID) on mitochondrial function, measured directly in the failing human heart, is unknown. Methods and results Left ventricular samples were obtained from 91 consecutive HF patients undergoing transplantation and 38 HF‐free organ donors (controls). Total myocardial iron content, mitochondrial respiration, citric acid cycle and respiratory chain enzyme activities, respiratory chain components (complex I–V), and protein content of reactive oxygen species (ROS)‐protective enzymes were measured in tissue homogenates to quantify mitochondrial function. Myocardial iron content was lower in HF compared with controls (156 ± 41 vs. 200 ± 38 µg·g−1 dry weight, P < 0.001), independently of anaemia. MID (the lowest iron tercile in HF) was associated with more extensive coronary disease and less beta‐blocker usage compared with non‐MID HF patients. Compared with controls, HF patients displayed reduced myocardial oxygen2 respiration and reduced activity of all examined mitochondrial enzymes (all P < 0.001). MID in HF was associated with preserved activity of respiratory chain enzymes but reduced activity of aconitase and citrate synthase (by –26% and –15%, P < 0.05) and reduced expression of catalase, glutathione peroxidase, and superoxide dismutase 2. Conclusion Myocardial iron content is decreased and mitochondrial functions are impaired in advanced HF. MID in HF is associated with diminished citric acid cycle enzyme activities and decreased ROS‐protecting enzymes. MID may contribute to altered myocardial substrate use and to worsening of mitochondrial dysfunction that exists in HF.
- 19 September 2016
- Published by Oxford University Press (OUP) in European Journal of Heart Failure
- Vol. 19 (4) , 522-530
Open AccessMyocardial Iron Content and Mitochondrial Function in Human Heart Failure: A Direct Tissue Analysis
Aims Iron replacement improves clinical status in iron‐deficient patients with heart failure (HF), but the pathophysiology is poorly understood. Iron is essential not only for erythropoiesis, but also for cellular bioenergetics. The impact of myocardial iron deficiency (MID) on mitochondrial function, measured directly in the failing human heart, is unknown. Methods and results Left ventricular samples were obtained from 91 consecutive HF patients undergoing transplantation and 38 HF‐free organ donors (controls). Total myocardial iron content, mitochondrial respiration, citric acid cycle and respiratory chain enzyme activities, respiratory chain components (complex I–V), and protein content of reactive oxygen species (ROS)‐protective enzymes were measured in tissue homogenates to quantify mitochondrial function. Myocardial iron content was lower in HF compared with controls (156 ± 41 vs. 200 ± 38 µg·g−1 dry weight, P < 0.001), independently of anaemia. MID (the lowest iron tercile in HF) was associated with more extensive coronary disease and less beta‐blocker usage compared with non‐MID HF patients. Compared with controls, HF patients displayed reduced myocardial oxygen2 respiration and reduced activity of all examined mitochondrial enzymes (all P < 0.001). MID in HF was associated with preserved activity of respiratory chain enzymes but reduced activity of aconitase and citrate synthase (by –26% and –15%, P < 0.05) and reduced expression of catalase, glutathione peroxidase, and superoxide dismutase 2. Conclusion Myocardial iron content is decreased and mitochondrial functions are impaired in advanced HF. MID in HF is associated with diminished citric acid cycle enzyme activities and decreased ROS‐protecting enzymes. MID may contribute to altered myocardial substrate use and to worsening of mitochondrial dysfunction that exists in HF.
- 29 August 2014
- Published by Springer Nature in Cell and Tissue Banking
- Vol. 15 (4) , 501-504
Donald Nixon Ross: Pioneer in open heart surgery and cardiovascular tissue banking died
- 29 August 2014
- Published by Springer Nature in Cell and Tissue Banking
- Vol. 15 (4) , 501-504
Donald Nixon Ross: Pioneer in open heart surgery and cardiovascular tissue banking died
- Open Access
- 24 October 2012
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 43 (2) , 431-433
Coroneo extra-aortic annuloplasty ring could stabilize even the pulmonary autograft annulus in a Ross operation
The Ross procedure is an alternative technique to mechanical prosthesis and recent evidence suggests that it is associated with improved long-term survival and quality of life. However, late pulmonary autograft failure can occur more frequently in patients with significant dilation of the aortic annulus. Here, we present a technical modification of the Ross procedure—a case report of a patient who underwent a Ross procedure in which the gross dilation of the aortic annulus was reduced by implantation of an extra-aortic Coronéo annuloplasty ring. Before discharge, we performed a multidetector computed tomography (MDCT) to verify the effect of extra-aortic annuloplasty on the geometry of the neoaortic root and particularly on the dimension of the aortic annulus. The result of the MDCT demonstrated that the ring sits in the optimal position at the level of aortoventricular base and that aortic annulus is significantly reduced.
- 24 October 2012
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 43 (2) , 431-433
Open AccessCoroneo extra-aortic annuloplasty ring could stabilize even the pulmonary autograft annulus in a Ross operation
The Ross procedure is an alternative technique to mechanical prosthesis and recent evidence suggests that it is associated with improved long-term survival and quality of life. However, late pulmonary autograft failure can occur more frequently in patients with significant dilation of the aortic annulus. Here, we present a technical modification of the Ross procedure—a case report of a patient who underwent a Ross procedure in which the gross dilation of the aortic annulus was reduced by implantation of an extra-aortic Coronéo annuloplasty ring. Before discharge, we performed a multidetector computed tomography (MDCT) to verify the effect of extra-aortic annuloplasty on the geometry of the neoaortic root and particularly on the dimension of the aortic annulus. The result of the MDCT demonstrated that the ring sits in the optimal position at the level of aortoventricular base and that aortic annulus is significantly reduced.