Tonometry after Intrastromal Corneal Ring Segments for Keratoconus
- 1 October 2017
- journal article
- research article
- Published by Wiley in Optometry and Vision Science
- Vol. 94 (10) , 986-992
Abstract
SIGNIFICANCE: Reliable intraocular pressure (IOP) measurement after intrastromal corneal ring segments (ICRS) implantation is a challenge because of altered corneal morphology. In this study, IOP is measured with four tonometers, compared with Goldmann applanation tonometry (GAT) values and the influence of corneal parameters is established. PURPOSE: This study compares IOP measurements made using different tonometers in patients implanted with ICRS and assesses the effects of central corneal thickness (CCT), corneal curvature, and corneal astigmatism on the IOP measurements obtained. METHODS: In this cross‐sectional study, IOP was measured using three different tonometers in 91 eyes of 91 patients with corneal ectasia implanted at least 6 months previously with ICRS. The tonometers tested were the TonoPen XL, Pascal dynamic contour tonometer (DCT), and iCare Pro rebound tonometer. GAT measurements were used as reference. Agreement among the IOPs provided by the different tonometers and the influence of corneal variables on the IOP measurements obtained were assessed using the Bland–Altman method, intraclass correlation coefficients, and multiple linear regression analysis. RESULTS: Mean IOP differences were GAT versus TonoPen XL −0.8 ± 3.07 mm Hg, GAT versus DCT −1.0 ± 3.26 mm Hg, and GAT versus iCare Pro 0.8 ± 2.92 mm Hg. Our multiple linear regression analysis identified CCT as a confounding factor affecting all the tonometer readings but DCT‐IOP. CONCLUSIONS: In patients fitted with ICRS, IOP measurements made using the iCare Pro and TonoPen XL showed most agreement with GAT. Intraocular pressure measurements made by DCT were unaffected by corneal topographic factors though this procedure slightly overestimated GAT readings.Keywords
This publication has 35 references indexed in Scilit:
- Keratoconus progression after intrastromal corneal ring segment implantation in young patients: Five-year follow-upJournal of Cataract & Refractive Surgery, 2015
- Rebound, Applanation, and Dynamic Contour Tonometry in Pathologic CorneasCornea, 2013
- Influence of corneal parameters in keratoconus on IOP readings obtained with different tonometersClinical and Experimental Optometry, 2013
- Comparison of deep anterior lamellar keratoplasty and intrastromal corneal ring segment implantation in advanced keratoconusJournal of Cataract & Refractive Surgery, 2012
- KeraRing Intrastromal Corneal Ring Segments for Correction of KeratoconusCornea, 2012
- Comparison of Dynamic Contour Tonometry and Goldmann Applanation Tonometry in KeratoconusCornea, 2011
- Corticosteroid-induced intraocular pressure elevation in keratoconus is common following uncomplicated penetrating keratoplastyEye, 2009
- Changes in Corneal Biomechanics and Intraocular Pressure Following LASIK Using Static, Dynamic, and Noncontact TonometryAmerican Journal of Ophthalmology, 2007
- Intraocular Pressure Measurements Using Dynamic Contour Tonometry after Laser In Situ KeratomileusisInvestigative Ophthalmology & Visual Science, 2003
- Intraocular Pressure and Photorefractive KeratectomyCornea, 2001