PAPaula Arribas-Pardo

Paula Arribas-Pardo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Paula Arribas-Pardo has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Peripapillary Vascular Density in Childhood Glaucoma: A Pilot Comparative Study with Age and Sex Matched Healthy Subjects

    by Flora Xydaki, Paula Arribas-Pardo, Barbara Burgos-Blasco, Julian Garcia-Feijoo, Carmen Mendez-Hernandez

    Purpose: The aim of this study concerns the evaluation of peripapillary vessel indices in childhood glaucoma (CG) and healthy subjects. Material and Methods: In this prospective, unicenter, observational cross-sectional study, patients with CG and age and sex-matched healthy subjects were included. We compared retinal nerve fiber layer (RNFL) measurements in optical coherence tomography (OCT), peripapillary vessel density (PVD), and the flux index (FI) of the superficial vascular plexus from OCT angiography (OCT-A) between CG patients and control groups. Results: We included 39 patients (68 eyes) with CG and 50 (95 eyes) healthy subjects. The peripapillary RNFL thickness, vessel density, and flux index were significantly lower in the CG group than in the control group. The mean PVD of CG patients was 0.52 ± 0.043%, compared with 0.55 ± 0.014%, p < 0.0001 in healthy subjects. The mean FI was 0.32 ± 0.054 versus 0.37 ± 0.028, p < 0.0001, in CG patients and healthy subjects, respectively. PVD and FI in the superior, inferior, and temporal sectors were significantly lower in CG. The peripapillary RNFL thickness showed a higher area under the ROC curve (AUROC) for discriminating healthy and CG eyes and was significantly different than the PVD (0.797, 95%CI 0.726–0.869; p < 0.0001 vs. 0.664, 95%CI 0.574–0.752; p 0.00037), p 0.012.Conclusions: PVD and FI show lower values in CG and correlate with RNFL thickness measurement but have lower diagnostic ability than RNFL thickness measurement. Our results reveal possible differences in the pathogenesis of microvascular compromise in childhood glaucoma patients.

  • Icare-Pro Rebound Tonometer Versus Hand-held Applanation Tonometer for Pediatric Screening

    by Paula Arribas-Pardo, Carmen Mendez-Hernández, Isabel Valls-Ferran, Diego Puertas-Bordallo

    Purpose: To compare intraocular pressure (IOP) measurements obtained using the new rebound tonometer Icare-Pro (Icare, Tiolat Oy, Helsinki, Finland) and the hand-held version of the Goldmann applanation tonometer (Perkins; Clement Clarke, Haag-Streit, Harlow, United Kingdom) in healthy children during clinical practice. Methods: In this prospective study, three IOP measurements were made using each tonometer in a single session, starting with the Icare-Pro. Participants were 173 non-anesthetized patients aged 1 to 16 years. Measurements were made in both eyes but only data for the right eye were entered in the analysis. Central corneal thickness, anterior chamber depth, and axial length were also measured in each patient. Data were compared by determining interclass correlation coefficients (ICCs) for each tonometer and representing the differences detected as Bland–Altman plots. Results: Good linear correlation was observed between IOP readings obtained using the Perkins and Icare-Pro tonometers ( r = 0.87, P < .001), although the Icare-Pro readings were slightly higher (mean IOP difference: 0.26 ± 1.58 mm Hg, P = .037). The 95% limits of agreement between the two methods were 2.8 to −3.4 mm Hg. The ICC was 0.857 (95% confidence interval: 0.810 to 0.893), indicating good agreement. For both tonometers, a low but significant correlation was detected between IOP and central corneal thickness or age. However, no correlation of IOP was found with axial length or anterior chamber depth. Conclusions: Pediatric IOP measurements determined using the new Icare-Pro rebound tonometer showed good correlation with those obtained using the hand-held Perkins applanation tonometer in a routine clinical examination with no need for general anesthesia. [ J Pediatr Ophthalmol Strabismus . 2018;55(6):382–386.]


  • Tonometry after Intrastromal Corneal Ring Segments for Keratoconus

    by Paula Arribas‐Pardo, Carmen Mendez‐Hernandez, Ricardo Cuiña‐Sardiña, José Manuel Benitez‐Del‐Castillo, Julian Garcia‐Feijoo

    SIGNIFICANCE: Reliable intraocular pressure (IOP) measurement after intrastromal corneal ring segments (ICRS) implantation is a challenge because of altered corneal morphology. In this study, IOP is measured with four tonometers, compared with Goldmann applanation tonometry (GAT) values and the influence of corneal parameters is established. PURPOSE: This study compares IOP measurements made using different tonometers in patients implanted with ICRS and assesses the effects of central corneal thickness (CCT), corneal curvature, and corneal astigmatism on the IOP measurements obtained. METHODS: In this cross‐sectional study, IOP was measured using three different tonometers in 91 eyes of 91 patients with corneal ectasia implanted at least 6 months previously with ICRS. The tonometers tested were the TonoPen XL, Pascal dynamic contour tonometer (DCT), and iCare Pro rebound tonometer. GAT measurements were used as reference. Agreement among the IOPs provided by the different tonometers and the influence of corneal variables on the IOP measurements obtained were assessed using the Bland–Altman method, intraclass correlation coefficients, and multiple linear regression analysis. RESULTS: Mean IOP differences were GAT versus TonoPen XL −0.8 ± 3.07 mm Hg, GAT versus DCT −1.0 ± 3.26 mm Hg, and GAT versus iCare Pro 0.8 ± 2.92 mm Hg. Our multiple linear regression analysis identified CCT as a confounding factor affecting all the tonometer readings but DCT‐IOP. CONCLUSIONS: In patients fitted with ICRS, IOP measurements made using the iCare Pro and TonoPen XL showed most agreement with GAT. Intraocular pressure measurements made by DCT were unaffected by corneal topographic factors though this procedure slightly overestimated GAT readings.