Estimating the accuracy of optic nerve sheath diameter measurement using a pocket-sized, handheld ultrasound on a simulation model
Open Access
- 10 November 2016
- journal article
- research article
- Published by Springer Nature in The Ultrasound Journal
- Vol. 8 (1) , 1-5
Abstract
Ultrasound measurement of optic nerve sheath diameter (ONSD) appears to be a promising, rapid, non-invasive bedside tool for identification of elevated intra-cranial pressure. With improvements in ultrasound technology, machines are becoming smaller; however, it is unclear if these ultra-portable handheld units have the resolution to make these measurements precisely. In this study, we estimate the accuracy of ONSD measurement in a pocket-sized ultrasound unit. Utilizing a locally developed, previously validated model of the eye, ONSD was measured by two expert observers, three times with two machines and on five models with different optic nerve sheath sizes. A pocket ultrasound (Vscan, GE Healthcare) and a standard portable ultrasound (M-Turbo, SonoSite) were used to measure the models. Data was analyzed by Bland–Altman plot and intra-class correlation coefficient (ICC). The ICC between raters for the SonoSite was 0.878, and for the Vscan was 0.826. The between-machine agreement ICC was 0.752. Bland–Altman agreement analysis between the two ultrasound methods showed an even spread across the range of sheath sizes, and that the Vscan tended to read on average 0.33 mm higher than the SonoSite for each measurement, with a standard deviation of 0.65 mm. Accurate ONSD measurement may be possible utilizing pocket-sized, handheld ultrasound devices despite their small screen size, lower resolution, and lower probe frequencies. Further study in human subjects is warranted for all newer handheld ultrasound models as they become available on the market.Keywords
Funding Information
- Health Sciences Centre Foundation
- University of Manitoba Department of Surgery GFT Research Grant
This publication has 19 references indexed in Scilit:
- Ultrasound assessment of optic nerve sheath diameter in healthy volunteersJournal of Critical Care, 2016
- Reproducibility and accuracy of optic nerve sheath diameter assessment using ultrasound compared to magnetic resonance imagingBMC Neurology, 2013
- A Unique Model for Ultrasound Assessment of Optic Nerve Sheath DiameterCanadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques, 2013
- Measurement of the Optic Nerve Sheath Diameter in Children: Comparison Between Transbulbar Sonography and Magnetic Resonance ImagingUltraschall in der Medizin - European Journal of Ultrasound, 2011
- Transcranial Doppler to Screen on Admission Patients With Mild to Moderate Traumatic Brain InjuryNeurosurgery, 2011
- Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysisIntensive Care Medicine, 2011
- Intra‐ and Interobsever Reliability of Sonographic Assessment of the Optic Nerve Sheath Diameter in Healthy AdultsJournal of Neuroimaging, 2010
- Transcranial color-coded duplex sonography allows to assess cerebral perfusion pressure noninvasively following severe traumatic brain injuryActa Neurochirurgica, 2010
- Correlation of pulsatility index with intracranial pressure in traumatic brain injuryTurkish Neurosurgery, 2010
- Transcranial doppler recordings in raised intracranial pressureActa Neurologica Scandinavica, 1993