BUBertram Unger

Bertram Unger

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bertram Unger has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Design and Validity Evidence for a Unique Endoscopy Simulator Using a Commercial Video Game

    by Garrett Johnson, Ashley Vergis, Bertram Unger, Jason Park, Lawrence Gillman

    Procedural simulation enhances early endoscopy training. Multiple commercial simulators are available; however, their application is limited by cost and poor user compliance. First-person “shooter” (FPS) video games are popular. In this study, we aimed to show that a novel in-house designed colonoscope controller used to play an FPS video game shares similar constructs with real-life endoscopy. Participants completed the first three levels on an FPS video game, Portal (Valve Corporation, Bellevue, WA), first using a conventional controller and then the modified endoscope controller. A total of 12 expert endoscopists and 12 surgical residents with minimal endoscopy experience were evaluated based on completion time, button presses, and hand motion analyses. Experts outperformed novices for completion time (expert: 944 seconds; novice: 1,515 seconds; p = 0.006) and hand movements (expert: 1,263.1; novice: 2,052.6; p = 0.004) in using the novel colonoscope controller. There was no difference in button presses or total path length traveled. Furthermore, performance did not differ using conventional game controls. Experts outperformed novices using the endoscope but not the conventional controller with respect to the economy of movement and completion time. This result confirms that our endoscope-controlled video game shares similar paradigms with real-life endoscopy and serves as a first step toward creating a more enjoyable and cheaper alternative to commercially available endoscopy simulators.

  • The impact of hypertonic saline on cerebrovascular reactivity and compensatory reserve in traumatic brain injury: an exploratory analysis

    by Logan Froese, Joshua Dian, Carleen Batson, Alwyn Gomez, Bertram Unger, Frederick A. Zeiler

    Background Intravenous hypertonic saline is utilized commonly in critical care for treatment of acute or refractory elevations of intracranial pressure (ICP) in traumatic brain injury (TBI) patients. Though there is a clear understanding of the general physiological effects of a hypertonic saline solution over long periods of time, smaller epoch effects of hypertonic saline (HTS) have not been thoroughly analyzed. The aim of this study was to perform a direct evaluation of the high-frequency response of HTS on the cerebrovascular physiological responses in TBI. Methods We retrospectively reviewed our prospectively maintained adult TBI database for those with archived high-frequency cerebral physiology and available HTS treatment information. We evaluated different epochs of physiology around HTS bolus dosing, comparing pre- with post-HTS. We assessed for changes in slow fluctuations in ICP, pulse amplitude of ICP (AMP), cerebral perfusion pressure (CPP), mean arterial pressure (MAP), cerebrovascular reactivity (as measured through pressure reactivity index (PRx)), and cerebral compensatory reserve (correlation (R) between AMP (A) and ICP (P)). Comparisons of mean measures and percentage time above clinically relevant thresholds for the physiological parameters were compared pre- and post-HTS using descriptive statistics and Mann-Whitney U testing. We assessed for subgroups of physiological responses using latent profile analysis (LPA). Results Fifteen patients underwent 69 distinct bolus infusions of hypertonic saline. Apart from the well-documented decrease in ICP, there was also a reduction in AMP. The analysis of cerebrovascular reactivity response to HTS solution had two main effects. For patients with grossly impaired cerebrovascular reactivity pre-HTS (PRx > + 0.30), HTS bolus led to improved reactivity. However, for those with intact cerebrovascular reactivity pre-HTS (PRx < 0), HTS bolus demonstrated a trend towards more impaired reactivity. This indicates that HTS has different impacts, dependent on pre-bolus cerebrovascular status. There was no significant change in metrics of cerebral compensatory reserve. LPA failed to demonstrate any subgroups of physiological responses to HTS administration. Conclusions The direct decrease in ICP and AMP confirms that a bolus dose of a HTS solution is an effective therapeutic agent for intracranial hypertension. However, in patients with intact autoregulation, hypertonic saline may impair cerebral hemodynamics. These findings regarding cerebrovascular reactivity remain preliminary and require further investigation.


  • Open Access

    Comparison of high versus low frequency cerebral physiology for cerebrovascular reactivity assessment in traumatic brain injury: a multi-center pilot study

    by Eric P. Thelin, Rahul Raj, Bo-Michael Bellander, David Nelson, Anna Piippo-Karjalainen, Jari Siironen, Päivi Tanskanen, Gregory Hawryluk, Mohammed Hasen, Bertram Unger, et al.

    Current accepted cerebrovascular reactivity indices suffer from the need of high frequency data capture and export for post-acquisition processing. The role for minute-by-minute data in cerebrovascular reactivity monitoring remains uncertain. The goal was to explore the statistical time-series relationships between intra-cranial pressure (ICP), mean arterial pressure (MAP) and pressure reactivity index (PRx) using both 10-s and minute data update frequency in TBI. Prospective data from 31 patients from 3 centers with moderate/severe TBI and high-frequency archived physiology were reviewed. Both 10-s by 10-s and minute-by-minute mean values were derived for ICP and MAP for each patient. Similarly, PRx was derived using 30 consecutive 10-s data points, updated every minute. While long-PRx (L-PRx) was derived via similar methodology using minute-by-minute data, with L-PRx derived using various window lengths (5, 10, 20, 30, 40, and 60 min; denoted L-PRx_5, etc.). Time-series autoregressive integrative moving average (ARIMA) and vector autoregressive integrative moving average (VARIMA) models were created to analyze the relationship of these parameters over time. ARIMA modelling, Granger causality testing and VARIMA impulse response function (IRF) plotting demonstrated that similar information is carried in minute mean ICP and MAP data, compared to 10-s mean slow-wave ICP and MAP data. Shorter window L-PRx variants, such as L-PRx_5, appear to have a similar ARIMA structure, have a linear association with PRx and display moderate-to-strong correlations (r ~ 0.700, p < 0.0001 for each patient). Thus, these particular L-PRx variants appear closest in nature to standard PRx. ICP and MAP derived via 10-s or minute based averaging display similar statistical time-series structure and co-variance patterns. PRx and L-PRx based on shorter windows also behave similarly over time. These results imply certain L-PRx variants may carry similar information to PRx in TBI.


  • Open Access

    Estimating the accuracy of optic nerve sheath diameter measurement using a pocket-sized, handheld ultrasound on a simulation model

    by Garrett G. R. J. Johnson, Frederick A. Zeiler, Bertram Unger, Gregory Hansen, Dimitrios Karakitsos, Lawrence M. Gillman

    Ultrasound measurement of optic nerve sheath diameter (ONSD) appears to be a promising, rapid, non-invasive bedside tool for identification of elevated intra-cranial pressure. With improvements in ultrasound technology, machines are becoming smaller; however, it is unclear if these ultra-portable handheld units have the resolution to make these measurements precisely. In this study, we estimate the accuracy of ONSD measurement in a pocket-sized ultrasound unit. Utilizing a locally developed, previously validated model of the eye, ONSD was measured by two expert observers, three times with two machines and on five models with different optic nerve sheath sizes. A pocket ultrasound (Vscan, GE Healthcare) and a standard portable ultrasound (M-Turbo, SonoSite) were used to measure the models. Data was analyzed by Bland–Altman plot and intra-class correlation coefficient (ICC). The ICC between raters for the SonoSite was 0.878, and for the Vscan was 0.826. The between-machine agreement ICC was 0.752. Bland–Altman agreement analysis between the two ultrasound methods showed an even spread across the range of sheath sizes, and that the Vscan tended to read on average 0.33 mm higher than the SonoSite for each measurement, with a standard deviation of 0.65 mm. Accurate ONSD measurement may be possible utilizing pocket-sized, handheld ultrasound devices despite their small screen size, lower resolution, and lower probe frequencies. Further study in human subjects is warranted for all newer handheld ultrasound models as they become available on the market.


  • Open Access

    A unique method for estimating the reliability learning curve of optic nerve sheath diameter ultrasound measurement

    by Frederick A. Zeiler, Markus T. Ziesmann, Patrick Goeres, Bertram Unger, Jason Park, Dimitrios Karakitsos, Michael Blaivas, Ashley Vergis, Lawrence M. Gillman

    Optic nerve sheath diameter (ONSD) measurement using ultrasound has been proposed as a rapid, non-invasive, point of care technique to estimate intra-cranial pressure (ICP). Ultrasonic measurement of the optic nerve sheath can be quite challenging and there is limited literature surrounding learning curves for this technique. We attempted to develop a method to estimate the reliability learning curve for ONSD measurement utilizing a unique definition of reliability: a plateau in within-subject variability with unchanged between-subject variability. As part of a previously published study, a single operator measured the ONSD in 120 healthy volunteers over a 6-month period. Utilizing the assumption that the four measurements made on each subject during this study should be equal, the relationship of within-subject variance was described using a quadratic-plateau model as assessed by segmental polynomial (knot) regression. Segmental polynomial (knot) regression revealed a plateau in within-subject variance after the 21st subject. However, there was no difference in overall mean values [3.69 vs 3.68 mm (p = 0.884)] or between-subject variance [14.49 vs 11.92 (p = 0.54)] above or below this cutoff. This study suggests a significant finite learning curve associated with ONSD measurements. It also offers a unique method of calculating the learning curve associated with ONSD measurement.


  • Ultrasound assessment of optic nerve sheath diameter in healthy volunteers

    by Patrick Goeres, Frederick A. Zeiler, Bertram Unger, Dimitrios Karakitsos, Lawrence M. Gillman


  • Open Access

    Mixed reality temporal bone surgical dissector: Mechanical design

    by Jordan Brent Hochman, Nariman Sepehri, Vivek Rampersad, Jay Kraut, Milad Khazraee, Justyn Pisa, Bertram Unger

    Objective: The Development of a Novel Mixed Reality (MR) Simulation. An evolving training environment emphasizes the importance of simulation. Current haptic temporal bone simulators have difficulty representing realistic contact forces and while 3D printed models convincingly represent vibrational properties of bone, they cannot reproduce soft tissue. This paper introduces a mixed reality model, where the effective elements of both simulations are combined; haptic rendering of soft tissue directly interacts with a printed bone model. This paper addresses one aspect in a series of challenges, specifically the mechanical merger of a haptic device with an otic drill. This further necessitates gravity cancelation of the work assembly gripper mechanism. In this system, the haptic end-effector is replaced by a high-speed drill and the virtual contact forces need to be repositioned to the drill tip from the mid wand. Previous publications detail generation of both the requisite printed and haptic simulations. Method: Custom software was developed to reposition the haptic interaction point to the drill tip. A custom fitting, to hold the otic drill, was developed and its weight was offset using the haptic device. The robustness of the system to disturbances and its stable performance during drilling were tested. The experiments were performed on a mixed reality model consisting of two drillable rapid-prototyped layers separated by a free-space. Within the free-space, a linear virtual force model is applied to simulate drill contact with soft tissue. Results: Testing illustrated the effectiveness of gravity cancellation. Additionally, the system exhibited excellent performance given random inputs and during the drill's passage between real and virtual components of the model. No issues with registration at model boundaries were encountered. Conclusion: These tests provide a proof of concept for the initial stages in the development of a novel mixed-reality temporal bone simulator.


  • Open Access

    Gesture-controlled interactive three dimensional anatomy: a novel teaching tool in head and neck surgery

    by Jordan B Hochman, Bertram Unger, Jay Kraut, Justyn Pisa, Sabine Hombach-Klonisch

    There is a need for innovative anatomic teaching tools. This paper describes a three dimensional (3D) tool employing the Microsoft Kinect™. Using this instrument, 3D temporal bone anatomy can be manipulated with the use of hand gestures, in the absence of mouse or keyboard.


  • Open Access

    Comparison of cadaveric and isomorphic virtual haptic simulation in temporal bone training

    by Dana Wong, Bertram Unger, Jay Kraut, Justyn Pisa, Charlotte Rhodes, Jordan B Hochman

    Background: Virtual surgery may improve learning and provides an opportunity for pre-operative surgical rehearsal. We describe a novel haptic temporal bone simulator specifically developed for multicore processing and improved visual realism. A position locking algorithm for enhanced drill-bone interaction and haptic fidelity is further employed. The simulation construct is evaluated against cadaveric education. Methods: A voxel-based simulator was designed for multicore architecture employing Marching Cubes and Laplacian smoothing to perform real-time haptic and graphic rendering of virtual bone. Ten Otolaryngology trainees dissected a cadaveric temporal bone (CTB) followed by a virtual isomorphic haptic model (VM) based on derivative microCT data. Participants rated 1) physical characteristics, 2) specific anatomic constructs, 3) usefulness in skill development and 4) perceived educational value. The survey instrument employed a Likert scale (1-7). Results: Residents were equivocal about the physical properties of the VM, as cortical (3.2 ± 2.0) and trabecular (2.8 ± 1.6) bone drilling character was appraised as dissimilar to CTB. Overall similarity to cadaveric training was moderate (3.5 ± 1.8). Residents generally felt the VM was beneficial in skill development, rating it highest for translabyrinthine skull-base approaches (5.2 ± 1.3). The VM was considered an effective (5.4 ± 1.5) and accurate (5.7 ± 1.4) training tool which should be integrated into resident education (5.5 ± 1.4). The VM was thought to improve performance (5.3 ± 1.8) and confidence (5.3 ± 1.9) and was highly rated for anatomic learning (6.1 ± 1.9). Conclusion: Study participants found the VM to be a beneficial and effective platform for learning temporal bone anatomy and surgical techniques. They identify some concern with limited physical realism likely owing to the haptic device interface. This study is the first to compare isomorphic simulation in education. This significantly removes possible confounding features as the haptic simulation was based on derivative imaging.