Comparing Loose Clothing-Mounted Sensors with Body-Mounted Sensors in the Analysis of Walking
Open Access
Abstract
A person’s walking pattern can reveal important information about their health. Mounting multiple sensors onto loose clothing potentially offers a comfortable way of collecting data about walking and other human movement. This research investigates how well the data from three sensors mounted on the lateral side of clothing (on a pair of trousers near the waist, upper thigh and lower shank) correlate with the data from sensors mounted on the frontal side of the body. Data collected from three participants (two male, one female) for two days were analysed. Gait cycles were extracted based on features in the lower-shank accelerometry and analysed in terms of sensor-to-vertical angles (SVA). The correlations in SVA between the clothing- and body-mounted sensor pairs were analysed. Correlation coefficients above 0.76 were found for the waist sensor pairs, while the thigh and lower-shank sensor pairs had correlations above 0.90. The cyclical nature of gait cycles was evident in the clothing data, and it was possible to distinguish the stance and swing phases of walking based on features in the clothing data. Furthermore, simultaneously recording data from the waist, thigh, and shank was helpful in capturing the movement of the whole leg.Keywords
Funding Information
- University Grant commission, Sri Lanka (UGC/VC/ DRIC/PG2016(I)/UCSC/01)
This publication has 39 references indexed in Scilit:
- IMU-Based Joint Angle Measurement for Gait AnalysisSensors, 2014
- Gait Analysis Methods: An Overview of Wearable and Non-Wearable Systems, Highlighting Clinical ApplicationsSensors, 2014
- COMPARISON OF GAIT SYMMETRY INDICATORS IN OVERGROUND WALKING AND TREADMILL WALKING USING WIRELESS GYROSCOPESJournal of Mechanics in Medicine and Biology, 2014
- Effects of accelerometer coupling on step counting accuracy in healthy older adultsHealth and Technology, 2012
- Estimating Three-Dimensional Orientation of Human Body Parts by Inertial/Magnetic SensingSensors, 2011
- Comparing Time Histories for Validation of Simulation Models: Error Measures and MetricsJournal of Dynamic Systems, Measurement, and Control, 2010
- Gait Event Detection on Level Ground and Incline Walking Using a Rate GyroscopeSensors, 2010
- Motor Patterns in Human Walking and RunningJournal of Neurophysiology, 2006
- Automated estimation of initial and terminal contact timing using accelerometers; development and validation in transtibial amputees and controlsIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2005
- Assessment of Walking Features From Foot Inertial SensingIEEE Transactions on Biomedical Engineering, 2005