William S. Harwin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
William S. Harwin has a total of 182 co-authors. Here are the top co-authors by number of shared publications:
Rui C. V. Loureiro
Interactive Systems Lab, School of Science and Technology, Middlesex University, London, UK
8 shared publicationsKiyoshi Nagai
Department of Robotics, College of Science and Engineering, Ritsumeikan University, 1-1-1 Noji higashi, Kusatsu-shi, Shiga 525-8577, Japan
7 shared publications- Faustina Hwang
University of Reading
6 shared publications - Robert Simon Sherratt
Department of Biomedical Engineering, University of Reading, Reading RG6 6AY, UK
5 shared publications Shoupu Chen
Center for Appl. Sci. & Eng., Delaware Univ., Newark, DE, USA
5 shared publications- Balazs Janko
Department of Biomedical Engineering, University of Reading, Reading RG6 6AY, UK
4 shared publications
Latest Publications
- Open Access
- 17 October 2023
- Published by Springer Nature in Scientific Data
- Vol. 10 (1) , 1-11
Inertial measurement data from loose clothing worn on the lower body during everyday activities
Embedding sensors into clothing is promising as a way for people to wear multiple sensors easily, for applications such as long-term activity monitoring. To our knowledge, this is the first published dataset collected from sensors in loose clothing. 6 Inertial Measurement Units (IMUs) were configured as a ‘sensor string’ and attached to casual trousers such that there were three sensors on each leg near the waist, thigh, and ankle/lower-shank. Participants also wore an Actigraph accelerometer on their dominant wrist. The dataset consists of 15 participant-days worth of data collected from 5 healthy adults (age range: 28–48 years, 3 males and 2 females). Each participant wore the clothes with sensors for between 1 and 4 days for 5–8 hours per day. Each day, data were collected while participants completed a fixed circuit of activities (with a video ground truth) as well as during free day-to-day activities (with a diary). This dataset can be used to analyse human movements, transitional movements, and postural changes based on a range of features.
- 17 October 2023
- Published by Springer Nature in Scientific Data
- Vol. 10 (1) , 1-11
Open AccessInertial measurement data from loose clothing worn on the lower body during everyday activities
Embedding sensors into clothing is promising as a way for people to wear multiple sensors easily, for applications such as long-term activity monitoring. To our knowledge, this is the first published dataset collected from sensors in loose clothing. 6 Inertial Measurement Units (IMUs) were configured as a ‘sensor string’ and attached to casual trousers such that there were three sensors on each leg near the waist, thigh, and ankle/lower-shank. Participants also wore an Actigraph accelerometer on their dominant wrist. The dataset consists of 15 participant-days worth of data collected from 5 healthy adults (age range: 28–48 years, 3 males and 2 females). Each participant wore the clothes with sensors for between 1 and 4 days for 5–8 hours per day. Each day, data were collected while participants completed a fixed circuit of activities (with a video ground truth) as well as during free day-to-day activities (with a diary). This dataset can be used to analyse human movements, transitional movements, and postural changes based on a range of features.
- Open Access
- 18 October 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (10) , e0264126
A novel approach for modelling and classifying sit-to-stand kinematics using inertial sensors
Sit-to-stand transitions are an important part of activities of daily living and play a key role in functional mobility in humans. The sit-to-stand movement is often affected in older adults due to frailty and in patients with motor impairments such as Parkinson’s disease leading to falls. Studying kinematics of sit-to-stand transitions can provide insight in assessment, monitoring and developing rehabilitation strategies for the affected populations. We propose a three-segment body model for estimating sit-to-stand kinematics using only two wearable inertial sensors, placed on the shank and back. Reducing the number of sensors to two instead of one per body segment facilitates monitoring and classifying movements over extended periods, making it more comfortable to wear while reducing the power requirements of sensors. We applied this model on 10 younger healthy adults (YH), 12 older healthy adults (OH) and 12 people with Parkinson’s disease (PwP). We have achieved this by incorporating unique sit-to-stand classification technique using unsupervised learning in the model based reconstruction of angular kinematics using extended Kalman filter. Our proposed model showed that it was possible to successfully estimate thigh kinematics despite not measuring the thigh motion with inertial sensor. We classified sit-to-stand transitions, sitting and standing states with the accuracies of 98.67%, 94.20% and 91.41% for YH, OH and PwP respectively. We have proposed a novel integrated approach of modelling and classification for estimating the body kinematics during sit-to-stand motion and successfully applied it on YH, OH and PwP groups.
- 18 October 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (10) , e0264126
Open AccessA novel approach for modelling and classifying sit-to-stand kinematics using inertial sensors
Sit-to-stand transitions are an important part of activities of daily living and play a key role in functional mobility in humans. The sit-to-stand movement is often affected in older adults due to frailty and in patients with motor impairments such as Parkinson’s disease leading to falls. Studying kinematics of sit-to-stand transitions can provide insight in assessment, monitoring and developing rehabilitation strategies for the affected populations. We propose a three-segment body model for estimating sit-to-stand kinematics using only two wearable inertial sensors, placed on the shank and back. Reducing the number of sensors to two instead of one per body segment facilitates monitoring and classifying movements over extended periods, making it more comfortable to wear while reducing the power requirements of sensors. We applied this model on 10 younger healthy adults (YH), 12 older healthy adults (OH) and 12 people with Parkinson’s disease (PwP). We have achieved this by incorporating unique sit-to-stand classification technique using unsupervised learning in the model based reconstruction of angular kinematics using extended Kalman filter. Our proposed model showed that it was possible to successfully estimate thigh kinematics despite not measuring the thigh motion with inertial sensor. We classified sit-to-stand transitions, sitting and standing states with the accuracies of 98.67%, 94.20% and 91.41% for YH, OH and PwP respectively. We have proposed a novel integrated approach of modelling and classification for estimating the body kinematics during sit-to-stand motion and successfully applied it on YH, OH and PwP groups.
- 1 September 2022
- Published by Springer Nature
- p. 3-13
A Distributed Approach to Haptic Simulation
- Open Access
Comparing Loose Clothing-Mounted Sensors with Body-Mounted Sensors in the Analysis of Walking
A person’s walking pattern can reveal important information about their health. Mounting multiple sensors onto loose clothing potentially offers a comfortable way of collecting data about walking and other human movement. This research investigates how well the data from three sensors mounted on the lateral side of clothing (on a pair of trousers near the waist, upper thigh and lower shank) correlate with the data from sensors mounted on the frontal side of the body. Data collected from three participants (two male, one female) for two days were analysed. Gait cycles were extracted based on features in the lower-shank accelerometry and analysed in terms of sensor-to-vertical angles (SVA). The correlations in SVA between the clothing- and body-mounted sensor pairs were analysed. Correlation coefficients above 0.76 were found for the waist sensor pairs, while the thigh and lower-shank sensor pairs had correlations above 0.90. The cyclical nature of gait cycles was evident in the clothing data, and it was possible to distinguish the stance and swing phases of walking based on features in the clothing data. Furthermore, simultaneously recording data from the waist, thigh, and shank was helpful in capturing the movement of the whole leg.
Open AccessComparing Loose Clothing-Mounted Sensors with Body-Mounted Sensors in the Analysis of Walking
A person’s walking pattern can reveal important information about their health. Mounting multiple sensors onto loose clothing potentially offers a comfortable way of collecting data about walking and other human movement. This research investigates how well the data from three sensors mounted on the lateral side of clothing (on a pair of trousers near the waist, upper thigh and lower shank) correlate with the data from sensors mounted on the frontal side of the body. Data collected from three participants (two male, one female) for two days were analysed. Gait cycles were extracted based on features in the lower-shank accelerometry and analysed in terms of sensor-to-vertical angles (SVA). The correlations in SVA between the clothing- and body-mounted sensor pairs were analysed. Correlation coefficients above 0.76 were found for the waist sensor pairs, while the thigh and lower-shank sensor pairs had correlations above 0.90. The cyclical nature of gait cycles was evident in the clothing data, and it was possible to distinguish the stance and swing phases of walking based on features in the clothing data. Furthermore, simultaneously recording data from the waist, thigh, and shank was helpful in capturing the movement of the whole leg.
- Open Access
Comparing Clothing-Mounted Sensors with Wearable Sensors for Movement Analysis and Activity Classification
Inertial sensors are a useful instrument for long term monitoring in healthcare. In many cases, inertial sensor devices can be worn as an accessory or integrated into smart textiles. In some situations, it may be beneficial to have data from multiple inertial sensors, rather than relying on a single worn sensor, since this may increase the accuracy of the analysis and better tolerate sensor errors. Integrating multiple sensors into clothing improves the feasibility and practicality of wearing multiple devices every day, in approximately the same location, with less likelihood of incorrect sensor orientation. To facilitate this, the current work investigates the consequences of attaching lightweight sensors to loose clothes. The intention of this paper is to discuss how data from these clothing sensors compare with similarly placed body worn sensors, with additional consideration of the resulting effects on activity recognition. This study compares the similarity between the two signals (body worn and clothing), collected from three different clothing types (slacks, pencil skirt and loose frock), across multiple daily activities (walking, running, sitting, and riding a bus) by calculating correlation coefficients for each sensor pair. Even though the two data streams are clearly different from each other, the results indicate that there is good potential of achieving high classification accuracy when using inertial sensors in clothing.
Open AccessComparing Clothing-Mounted Sensors with Wearable Sensors for Movement Analysis and Activity Classification
Inertial sensors are a useful instrument for long term monitoring in healthcare. In many cases, inertial sensor devices can be worn as an accessory or integrated into smart textiles. In some situations, it may be beneficial to have data from multiple inertial sensors, rather than relying on a single worn sensor, since this may increase the accuracy of the analysis and better tolerate sensor errors. Integrating multiple sensors into clothing improves the feasibility and practicality of wearing multiple devices every day, in approximately the same location, with less likelihood of incorrect sensor orientation. To facilitate this, the current work investigates the consequences of attaching lightweight sensors to loose clothes. The intention of this paper is to discuss how data from these clothing sensors compare with similarly placed body worn sensors, with additional consideration of the resulting effects on activity recognition. This study compares the similarity between the two signals (body worn and clothing), collected from three different clothing types (slacks, pencil skirt and loose frock), across multiple daily activities (walking, running, sitting, and riding a bus) by calculating correlation coefficients for each sensor pair. Even though the two data streams are clearly different from each other, the results indicate that there is good potential of achieving high classification accuracy when using inertial sensors in clothing.
- Open Access
- 10 September 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-12
Novel instrumented frame for standing exercising of users with complete spinal cord injuries
This paper describes a Functional Electrical Stimulation (FES) standing system for rehabilitation of bone mineral density (BMD) in people with Spinal Cord Injury (SCI). BMD recovery offers an increased quality of life for people with SCI by reducing their risk of fractures. The standing system developed comprises an instrumented frame equipped with force plates and load cells, a motion capture system, and a purpose built 16-channel FES unit. This system can simultaneously record and process a wide range of biomechanical data to produce muscle stimulation which enables users with SCI to safely stand and exercise. An exergame provides visual feedback to the user to assist with upper-body posture control during exercising. To validate the system an alternate weight-shift exercise was used; 3 participants with complete SCI exercised in the system for 1 hour twice-weekly for 6 months. We observed ground reaction forces over 70% of the full body-weight distributed to the supporting leg at each exercising cycle. Exercise performance improved for each participant by an increase of 13.88 percentage points of body-weight in the loading of the supporting leg during the six-month period. Importantly, the observed ground reaction forces are of higher magnitude than other studies which reported positive effects on BMD. This novel instrumentation aims to investigate weight bearing standing therapies aimed at determining the biomechanics of lower limb joint force actions and postural kinematics.
- 10 September 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-12
Open AccessNovel instrumented frame for standing exercising of users with complete spinal cord injuries
This paper describes a Functional Electrical Stimulation (FES) standing system for rehabilitation of bone mineral density (BMD) in people with Spinal Cord Injury (SCI). BMD recovery offers an increased quality of life for people with SCI by reducing their risk of fractures. The standing system developed comprises an instrumented frame equipped with force plates and load cells, a motion capture system, and a purpose built 16-channel FES unit. This system can simultaneously record and process a wide range of biomechanical data to produce muscle stimulation which enables users with SCI to safely stand and exercise. An exergame provides visual feedback to the user to assist with upper-body posture control during exercising. To validate the system an alternate weight-shift exercise was used; 3 participants with complete SCI exercised in the system for 1 hour twice-weekly for 6 months. We observed ground reaction forces over 70% of the full body-weight distributed to the supporting leg at each exercising cycle. Exercise performance improved for each participant by an increase of 13.88 percentage points of body-weight in the loading of the supporting leg during the six-month period. Importantly, the observed ground reaction forces are of higher magnitude than other studies which reported positive effects on BMD. This novel instrumentation aims to investigate weight bearing standing therapies aimed at determining the biomechanics of lower limb joint force actions and postural kinematics.
- Open Access
- 15 July 2019
- Published by MDPI AG in Electronics
- Vol. 8 (7) , 789
Task Scheduling to Constrain Peak Current Consumption in Wearable Healthcare Sensors
Small embedded systems, in our case wearable healthcare devices, have significant engineering challenges to reduce their power consumption for longer battery life, while at the same time supporting ever-increasing processing requirements for more intelligent applications. Research has primarily focused on achieving lower power operation through hardware designs and intelligent methods of scheduling software tasks, all with the objective of minimizing the overall consumed electrical power. However, such an approach inevitably creates points in time where software tasks and peripherals coincide to draw large peaks of electrical current, creating short-term electrical stress for the battery and power regulators, and adding to electromagnetic interference emissions. This position paper proposes that the power profile of an embedded device using a real-time operating system (RTOS) will significantly benefit if the task scheduler is modified to be informed of the electrical current profile required for each task. This enables the task scheduler to schedule tasks that require large amounts of current to be spread over time, thus constraining the peak current that the system will draw. We propose a solution to inform the task scheduler of a tasks’ power profile, and we discuss our application scenario, which clearly benefited from the proposal.
- 15 July 2019
- Published by MDPI AG in Electronics
- Vol. 8 (7) , 789
Open AccessTask Scheduling to Constrain Peak Current Consumption in Wearable Healthcare Sensors
Small embedded systems, in our case wearable healthcare devices, have significant engineering challenges to reduce their power consumption for longer battery life, while at the same time supporting ever-increasing processing requirements for more intelligent applications. Research has primarily focused on achieving lower power operation through hardware designs and intelligent methods of scheduling software tasks, all with the objective of minimizing the overall consumed electrical power. However, such an approach inevitably creates points in time where software tasks and peripherals coincide to draw large peaks of electrical current, creating short-term electrical stress for the battery and power regulators, and adding to electromagnetic interference emissions. This position paper proposes that the power profile of an embedded device using a real-time operating system (RTOS) will significantly benefit if the task scheduler is modified to be informed of the electrical current profile required for each task. This enables the task scheduler to schedule tasks that require large amounts of current to be spread over time, thus constraining the peak current that the system will draw. We propose a solution to inform the task scheduler of a tasks’ power profile, and we discuss our application scenario, which clearly benefited from the proposal.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2019, 488-493
Multi-Compliance Printing Techniques for the Fabrication of Customisable Hand Exoskeletons
To be successful, hand exoskeletons require customisable low encumbrance design with multi-compliant materials. This paper details the modification and testing of a fused filament fabrication printer to produce three categories of multi-compliant material that can be incorporated into the design of hand exoskeletons. Demonstration of the multi-compliant material for some common problems in hand exoskeleton design are presented. This method of manufacturing multi-compliant materials could result in widespread use of exoskeleton design in both the rehabilitation and assistive fields.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2019, 488-493
Multi-Compliance Printing Techniques for the Fabrication of Customisable Hand Exoskeletons
To be successful, hand exoskeletons require customisable low encumbrance design with multi-compliant materials. This paper details the modification and testing of a fused filament fabrication printer to produce three categories of multi-compliant material that can be incorporated into the design of hand exoskeletons. Demonstration of the multi-compliant material for some common problems in hand exoskeleton design are presented. This method of manufacturing multi-compliant materials could result in widespread use of exoskeleton design in both the rehabilitation and assistive fields.
- 6 June 2018
- Published by Springer Nature
- p. 94-105
Modelling the Air-Gap Field Strength of Electric Machines to Improve Performance of Haptic Mechanisms
- 6 June 2018
- Published by Springer Nature
- p. 94-105
Modelling the Air-Gap Field Strength of Electric Machines to Improve Performance of Haptic Mechanisms
- Open Access
- 25 October 2017
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2017 (10) , 548-556
Experimental validation of the recovery effect in batteries for wearable sensors and healthcare devices discovering the existence of hidden time constants
Wearable sensors and healthcare devices use small lightweight batteries to power their operations of monitoring and tracking. It becomes absolutely vital to effectively utilise all the available battery charge for device longevity between charges. The electrochemical recovery effect enables the extraction of more power from the battery when implementing idle times in between use cycles, and has been used to develop various power management techniques. However, there is no evidence concerning the actual increase in available power that can be attained using the recovery effect. Also, this property cannot be generalised on all the battery chemistries since it is an innate phenomenon, relying on the anode/cathode material. Indeed recent developments suggest that recovery effect does not exist at all. Experimental results to verify the presence and level of the recovery effect in commonly used battery chemistries in wearable sensors and healthcare devices are presented. The results have revealed that the recovery effect significantly does exist in certain batteries, and importantly the authors show that it is also comprised of two different time constants. This novel finding has important implications for the development of power management techniques that utilise the recovery effect with application in a large range of battery devices.
- 25 October 2017
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2017 (10) , 548-556
Open AccessExperimental validation of the recovery effect in batteries for wearable sensors and healthcare devices discovering the existence of hidden time constants
Wearable sensors and healthcare devices use small lightweight batteries to power their operations of monitoring and tracking. It becomes absolutely vital to effectively utilise all the available battery charge for device longevity between charges. The electrochemical recovery effect enables the extraction of more power from the battery when implementing idle times in between use cycles, and has been used to develop various power management techniques. However, there is no evidence concerning the actual increase in available power that can be attained using the recovery effect. Also, this property cannot be generalised on all the battery chemistries since it is an innate phenomenon, relying on the anode/cathode material. Indeed recent developments suggest that recovery effect does not exist at all. Experimental results to verify the presence and level of the recovery effect in commonly used battery chemistries in wearable sensors and healthcare devices are presented. The results have revealed that the recovery effect significantly does exist in certain batteries, and importantly the authors show that it is also comprised of two different time constants. This novel finding has important implications for the development of power management techniques that utilise the recovery effect with application in a large range of battery devices.