Reliability and Concurrent Validity of the Perometer for Measuring Hand Volume in Women With and Without Lymphedema
- 1 March 2011
- journal article
- research article
- Published by SAGE Publications in Lymphatic Research and Biology
- Vol. 9 (1) , 13-18
Abstract
Background: Lymphedema of hand after breast cancer treatment causes significant loss of hand function. Although there are several ways of assessing limb volume, measuring hand volume has been problematic due to technical difficulties associated with assessment of finger volumes. The aim of this study was to investigate the criterion validity and reliability of Perometer™ for measuring hand volume in woman with and without lymphedema. Methods and Results: Hand volume of forty women with (n = 20) and without lymphedema (n = 20) was assessed twice by one rater and once by another rater using the Perometer, and once by one rater using the water volumetry method. Intra- and inter-rater reliability was determined from the intraclass correlation coefficients and Percent Close Agreement. Agreement between the Perometer and water volumetry was determined using a limit of agreement and Lin's concordance correlation. The Perometer had high intra [ICC2,1 = 0.989 (95% CI: 0.98–0.99)] and inter-rater reliability [ICC2,1 = 0.993 (95% CI: 0.99–1.0)]. Percent close agreement revealed that 80% of the measures were within 9 ml for inter-rater reliability and within 15 ml for intra-rater reliability. In addition, there was high concordance between hand volumes obtained with the Perometer and water volumetry method (Rc = 0.88). However, the Perometer overestimated the volume of hand compared to water volumetry method (bias: 7.5%). Conclusions: The Perometer can be used with high reliability to measure hand volume but caution should be exercised when data are compared with measures derived from the water volumetry method.Keywords
This publication has 9 references indexed in Scilit:
- Assessment of Breast Cancer-Related Arm Lymphedema—Comparison of Physical Measurement Methods and Self-ReportCancer Investigation, 2009
- Arm/hand swelling and perceived functioning among breast cancer survivors 12 years post-diagnosis: CALGB 79804Journal of Cancer Survivorship, 2008
- Impact of lymphoedema on arm function and health-related quality of life in women following breast cancer surgeryJournal of Rehabilitation Medicine, 2008
- An Obturator Reduces Time for Volumetric Measurements of the Foot and AnkleJournal of Orthopaedic & Sports Physical Therapy, 2004
- Figure-of-eight method of measuring hand size:Journal of Hand Therapy, 2003
- The effect of different knee angles on knee volume measured with the Perometer® device in uninjured subjects*Clinical Physiology and Functional Imaging, 2003
- Development and Evaluation of a Precision Forearm and Hand Volumeter and Measuring CylinderJournal of Hand Therapy, 1996
- Evaluating the Hand: Issues in Reliability and ValidityPhysical Therapy, 1989
- A Concordance Correlation Coefficient to Evaluate Reproducibility1989