Standardization of flow cytometric detection of antigen expression
- 12 January 2024
- journal article
- research article
- Published by Wiley in Cytometry Part B: Clinical Cytometry
- Vol. 106 (1) , 25-34
Abstract
Since response to antigen‐based immunotherapy relies upon the level of tumor antigen expression we developed an antigen quantification assay using ABC values. Antigen quantification as a clinical assay requires methods for quality control and for interlaboratory and inter‐cytometer platform standardization. A single lot of Cytotrol™ Lyophilized Control Cells (Beckman Coulter) used for all studies. The variability in antigen quantification across 4 different instrument platforms in 2 separate laboratories was evaluated. The effect of the antibody clone utilized, importance of custom 1:1 molar ratio (fluorophore to protein, F/P) verses off‐the‐shelf antibodies, and QuantiBrite PE calibration verses linearity calibration combined with a single point scale transformation with CD4 as reference were determined. Use of single lot control cells allowed validation of reproducibility between flow cytometer platforms and laboratories and allowed assessment of different antibody lots, cocktail preparation, and different antibody clones. Off the shelf antibody preparations provide reproducible estimates of antigen density, however custom 1:1 unimolar antibody preparations should be utilized for definitive measurement of antigen expression.Geometric Mean fluorescent Intensity (GeoMFI) was not comparable across instruments and inter‐laboratory. The use of CD4 as the reference marker can minimize variability in ABC values. Comparable antigen quantification is vital in managing patients receiving antigen‐based immunotherapy. If this assay is to be utilized in a clinical setting, quality control methods have to be instituted to assure reproducibility and allow validation across laboratories. We have demonstrated that use of a lyophilized cell control is highly valuable in achieveing these goals.Keywords
This publication has 22 references indexed in Scilit:
- Quantitative Flow Cytometry Measurements in Antibodies Bound per Cell Based on a CD4 ReferenceCurrent Protocols in Cytometry, 2016
- Convergence of Acquired Mutations and Alternative Splicing of CD19 Enables Resistance to CART-19 ImmunotherapyCancer Discovery, 2015
- Consistent, multi‐instrument single tube quantification of CD20 in antibody bound per cell based on CD4 referenceCytometry Part B: Clinical Cytometry, 2015
- T cells expressing CD19 chimeric antigen receptors for acute lymphoblastic leukaemia in children and young adults: a phase 1 dose-escalation trialThe Lancet, 2015
- Safety and activity of blinatumomab for adult patients with relapsed or refractory B-precursor acute lymphoblastic leukaemia: a multicentre, single-arm, phase 2 studyThe Lancet Oncology, 2015
- Quantifying CD4 receptor protein in two human CD4+ lymphocyte preparations for quantitative flow cytometryClinical Proteomics, 2014
- Human CD4+ lymphocytes for antigen quantification: Characterization using conventional flow cytometry and mass cytometryCytometry Part A, 2012
- Variables in the quantification of CD4 in normals and hairy cell leukemia patientsCytometry Part B: Clinical Cytometry, 2010
- CD28 cosignalling does not affect the activation threshold in a chimeric antigen receptor-redirected T-cell attackGene Therapy, 2010
- Determination of CD4 antigen density on cells: Role of antibody valency, avidity, clones, and conjugationCytometry, 1998